Ozito PSA-001 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Ozito PSA-001 (6 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/6
PRESSURE
SWITCH
10 BAR
INSTRUCTION MANUAL
SPECIFICATIONS
Input: 220-240V~50Hz
Pump Max: 1.1kW, 10 Amps
Max. Pressure: 10 bar (1 Mpa)
Inlet & Outlet: 25.4mm (1“BSP) Male
Water Temp.: 1ºC to 35ºC
Cable Male Plug: 1.5m
Cable Female Socket: 0.5m
IP Rating: IP65
Weight: 1.7kg
PSA-001
STANDARD EQUIPMENT
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: O-rings, bearing,
seals gaskets.
WARNING
The following actions will result in the warranty being void.
• If the tool has been operated on a supply voltage other
than that specified on the tool.
• If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
• Failure to perform maintenance as set out within the
instruction manual.
• If the tool is disassembled or tampered with in any way.
• Professional, industrial or high frequency use.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
ozito.com.au
0518
Pressure Switch
Teflon Tape
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to
the online manual.
1. Discharge outlet
2. LED’s
3. Restart button
4. Brass union (knuckle)
5. Inlet
6. Female socket
7. Male plug
PRESSURE SWITCH
KNOW YOUR PRODUCT
1. ASSEMBLY
SETUP & PREPARATION
WARNING!: ENSURE THE PRESSURE SWITCH
IS DISCONNECTED FROM THE POWER SUPPLY
BEFORE PERFORMING ANY OF THE FOLLOWING
OPERATIONS.
ACCESSORIES
8. Teontape
Connecting the Pressure Switch
1. Screw the pressure switch
brass union to the transfer
pump outlet of a suitable
pump.Tightenrmlywitha
spanner (not included).
Note:Teontapeisrequiredonthreadstoensureawatertight
seal and prevent any leakage.
Connecting to the Pumps Suction Inlet
1. Insert 1” male threaded
adaptor (not included).
Tightenrmlywitha
spanner (not included).
2. Securely attach the
input hose or pipe (not
included) to the other end
of the adaptor. Ensure
you have the correct
diameter hose or pipe that
is compatible with your
water drawing source and
pump.
1
8
4
5
6
7
3
2
Primingthepumpisrequiredtopurgeairfromthehose.Don’t
operate the pump without it being primed.
1. Ensure the pump is
switched off at the mains
power.
2. Remove the priming plug
from the top of the pump
housing by turning anti
clockwise.
3. Fill the pump completely
with water. Ensure the
pump and inlet pipe or
hose are full. Replace the priming plug.
4. To fully prime the pump refer to “Starting the pump”.
2. PRIMING THE PUMP
OPERATION
WARNING!: THIS PRODUCT IS INTENDED
FOR PUMPING WATER IN A HOME DOMESTIC
APPLICATION. DO NOT USE IT FOR CORROSIVE,
ABRASIVE, EXPLOSIVE OR DANGEROUS LIQUIDS.
CAUTION. THE PUMP SHOULD BE FILLED WITH
WATER AFTER EACH NEW CONNECTION OR IF WATER
LOSS OR AIR INTAKE HAS OCCURRED. EXTENDED
OPERATION WITHOUT A WATER REFILL WILL DAMAGE
THE PUMP!
Connecting to the Discharge Outlet
1. Insert a 1” female threaded
adaptor (not included).
tightenrmlywitha
spanner.
2. Securely attach the
output hose or pipe (not
included) to the other end
of the adaptor. Ensure
you have the correct
diameter hose or pipe
that is compatible with
your water discharge
application.
Note: The discharge hose or pipe you are using must have a
minimum diameter of 19mm (3/4’’).
Note: Ensure the discharge hose or pipe is not restricted in any
way and nothing is obstructing the hose or pipe when the pump
is in operation.
WARNING!: RISK OF INJURY! IF THE
COMPONENTS ARE NOT COMPRESSION-PROOF
OR IF THEY ARE IMPROPERLY INSTALLED, THE
PRESSURE LINE COULD BURST DURING OPERATION.
Connecting to the Female Socket
1. Connect the pump power
cord plug to the pressure
switch female socket
Product specificaties
Merk: | Ozito |
Categorie: | Pomp |
Model: | PSA-001 |
Heb je hulp nodig?
Als je hulp nodig hebt met Ozito PSA-001 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Ozito
12 Juni 2023
31 Mei 2023
21 Mei 2023
29 April 2023
25 April 2023
8 April 2023
2 April 2023
28 Maart 2023
15 Maart 2023
25 Februari 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp Zéfal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Eco-Flo
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
13 November 2024
12 November 2024
12 November 2024
11 November 2024
5 November 2024
5 November 2024
4 November 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024