Ozito PXBVK-4182 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Ozito PXBVK-4182 (12 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
SPECIFICATIONS
Input: 18V x 2
No Load Speed: 8,000-14,000/min
Air Speed Max.: 230km/hr
Suction Power Max.: 700m/hr
Air Volume Max.: 225m/hr
Mulching Ratio: 10:1
Collection Bag: 45 litres
Noise Rating: 103dB
Tool Weight: 4.0kg (Blower)
5.3kg (Vacuum-Mulcher)
STANDARD EQUIPMENT
Motor Housing
CORDLESS
3-IN-1 BLOWER
VAC-MULCHER
ORIGINAL INSTRUCTIONS
ozito.com.au
Blower Tube
Collection Bag & Shoulder Strap
Additional Handle & Guide Wheels
Suction Tubes
PXBVS-0182
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU
MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS
WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE
OUR CUSTOMER SERVICE HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL
NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER
SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND
ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE
WARRANTY POLICY OR PROCEDURE.
OZITO Australia/New Zealand (Head Ofce) 25 Fox Drive, Dandenong South, Victoria, Australia 3175.
The benets provided under this warranty are in addition to other rights and
remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to
a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this
warranty, however, where you have suffered any additional direct loss as a result of
a defective product you may be able to claim such expenses by contacting our
customer service helpline above.
0221
WARNING
The following actions will result in the warranty being
void.
If the tool has been operated on a supply voltage other
than that specied on the tool.
If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
Failure to perform maintenance as set out within the instruction manual.
If the tool is disassembled or tampered with in any way
Professional, industrial or high frequency use.
5 YEAR REPLACEMENT WARRANTY
Your Product is guaranteed for a period of 60 months from the original date of
purchase and is intended for DIY (Do It Yourself) use only. If a product is defective it
will be replaced in accordance with the terms of this warranty. Lithium Ion
batteries and chargers are covered by a 36 month
warranty Warranty excludes consumable parts, for example: blower tubes,
collection bag, shoulder strap and included accessories.
KNOW YOUR PRODUCT
1. TUBE ASSEMBLY
1. Guide Wheels
2. Lower Suction Tube
3. Upper Suction Tube
4. Secondary Handle
5. Shoulder Strap Mount (Vac)
6. Battery Seating x 2
7. On/Off Switch
8. Collection Bag
9. Blower Tube
10. Shoulder Strap Mount (Blower)
11. Variable Speed Dial
12. Soft Grip Handle
13. Air Intake Cover
14. TURBO Boost Button
BLOWER VACUUM–MULCHER
1 2 3 4 5 6 7 8
BATTERY & CHARGER
This tool is compatible with all battery and chargers from the Ozito
Power X Change Range.
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to the
online manual.
ACCESSORIES
15. Shoulder Strap
10 119
WARNING!: ENSURE THE TOOL IS OFF AND THE
BATTERIES REMOVED BEFORE PERFORMING ANY OF
THE FOLLOWING OPERATIONS.
ASSEMBLY
Assembling the Vacuum Tube
2. Connect lower suction tube with the matching upper suction tube being
sure that the bag holding points are on the same side. Push together until
they are connected rmly and the guide lugs (one each side) click into the
corresponding recess.
1. Fit the guide wheels onto the
lower suction tube. Press and hold
the release button as you slide the
guide wheels onto the mount and
let it snap into place.
Note: The position can be changed at
any time by pressing the release button
again and sliding to any of 5 positions.
Make sure that it snaps into place correctly.
Bag Holding Point
Guide Lug
WARNING!: USE THE SUCTION TUBES ONLY IF IT IS
FULLY ASSEMBLED.
3. Fit the additional handle over the
mount on the upper suction tube.
Press
4. Insert the bolt from the side with
the hexagon recess.
5. Rotate the handle to the desired
position, t and tighten the knob
to secure in place.
12
13 14 15
BLOWER CONFIGURATION
VACUUM–MULCHER CONFIGURATION
SETUP & PREPARATION
2. BLOWER MODE SETUP 3. VACUUM-MULCHER MODE SETUP
2. Pull the sleeve to the top end of the blower tube.
3. Push the blower tube onto the motor housing, it will click in place when
fully inserted.
“CLICK”
“CLICK”
Note: Ensure the blower tube is pushed fully onto the motor housing
otherwise the motor will not start.
4. Attach the shoulder strap to the top
of the motor housing.
To use the shoulder strap simply slide
the strap over your shoulder so that
some of the weight of the blower can
be taken by your shoulder.
5. To remove blower tube, press the
release button and pull the blower
tube away from the motor housing.
PUSH
Knob
1. The air intake cover must be in
position on the suction opening
when using as a blower.
Note: Ensure the locking knob is
fully tightened otherwise the motor
will not start.
1. To install the vacuum tube
assembly, undo the air intake cover
knob and open the intake cover.
UNDO
2. Attach the vacuum tube
assembly and hinge it onto the
motor housing as shown.
3. Secure the vacuum tube assembly
in place by tightening the thumb
screw into the body of the motor
housing.
Note: Ensure the thumb screw is
fully tightened otherwise the motor will
not start.
Note: The intake cover is spring
loaded and simply rest under tension
against the vacuum tube.
4. Attach the collection bag onto the
motor housing, it will click in place
when fully inserted.
Note: Ensure the collection bag is
pushed fully onto the motor housing
otherwise the motor will not start.
“CLICK”
“CLICK”
5. Hang the two bag fastening
hooks onto the vacuum tube
bag holding points.
6. Attach the shoulder strap to the
top of the motor housing.
To use the shoulder strap simply
slide the strap over your shoulder
so that some of the weight of the
blower vac can be taken by your
shoulder.
7. To remove the collection bag, rst
unfasten hooks from the vacuum
tube holding points, then press
the release button and pull the
collection bag away from the
motor housing.
WARNING!: ENSURE THE TOOL IS OFF AND THE
BATTERIES REMOVED BEFORE PERFORMING ANY OF
THE FOLLOWING OPERATIONS.
WARNING!: ENSURE THE TOOL IS OFF AND THE
BATTERIES REMOVED BEFORE PERFORMING ANY OF
THE FOLLOWING OPERATIONS.


Product specificaties

Merk: Ozito
Categorie: Niet gecategoriseerd
Model: PXBVK-4182

Heb je hulp nodig?

Als je hulp nodig hebt met Ozito PXBVK-4182 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Ozito

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd