Moxa NPort 5450AI-M12 Handleiding

Moxa Server NPort 5450AI-M12

Lees hieronder de 📖 handleiding in het Nederlandse voor Moxa NPort 5450AI-M12 (113 pagina's) in de categorie Server. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/113
NPort 5000AI-M12 Series User Manual
First Edition, June 2012
www.moxa.com/product
© 2012 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
NPort 5000AI- M12 Series User Manual
The software described in this manual is furnished under a license agreement and may be used only in accordance with
the terms of that agreement.
Copyright Notice
Copyright ©2012
Moxa Inc.
All rights reserved.
Reproduction without permission is prohibited.
Trademarks
The MOXA logo is a registered trademark of Moxa Inc.
All other trademarks or registered marks in this manual belong to their respective manufacturers.
Disclaimer
Information in this document is subject to change without notice and does not represent a commitment on the part of
Moxa.
Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited
to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the
products and/or the programs described in this manual, at any time.
Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for
its use, or for any infringements on the rights of third parties that may result from its use.
This product might include unintentional technical or typographical errors. Changes are periodically made to the
information herein to correct such errors, and these changes are incorporated into new editions of the publication.
Technical Support Contact Information
www.moxa.com/support
Moxa Americas
Toll
- 1- - - free: 888 669 2872
Tel:
- - -+1 714 528 6777
Fax:
- - -+1 714 528 6778
Moxa China (Shanghai office)
Toll
- - - free: 800 820 5036
Tel:
- - - +86 21 5258 9955
Fax:
- - -+86 10 6872 3958
Moxa Europe
Tel:
- - -0 +49 89 3 70 03 99
Fax:
- - -+49 89 3 70 03 99 99
Moxa Asia
-Pacific
Tel:
-2- - +886 8919 1230
Fax:
-2- -+886 8919 1231
Table of Contents
1. Introduction ...................................................................................................................................... 1-1
Overview ........................................................................................................................................... 1-2
Package Checklist ............................................................................................................................... 1-2
Product Features ................................................................................................................................ 1-2
Product Specifications ......................................................................................................................... 1-2
2. Getting Started.................................................................................................................................. 2-1
NPort 5150AI-M12 Series Appearance ................................................................................................... 2-2
NPort 5250AI-M12 Series Appearance ................................................................................................... 2-2
NPort 5450AI-M12 Series Appearance ................................................................................................... 2-3
Connecting the Hardware..................................................................................................................... 2-3
Wiring Requirements ................................................................................................................... 2-3
Hardware Installation Procedure ........................................................................................................... 2-4
Panel/Wall Mounting .................................................................................................................... 2-4
DIN- Rail Mounting (optional) ........................................................................................................ 2-4
Connecting the Power .................................................................................................................. 2-5
Connecting to the Network ........................................................................................................... 2-5
Connecting to a Serial Device ....................................................................................................... 2-6
LED Indicators ............................................................................................................................ 2-6
3. Initial IP Address Configuration ........................................................................................................ 3-1
Initializing the NPort’s IP Address ......................................................................................................... 3-2
Factory Default IP Address ................................................................................................................... 3-2
NPort Administration Suite ................................................................................................................... 3-2
ARP................................................................................................................................................... 3-2
Telnet Console ................................................................................................................................... 3-3
Serial Console (19200, n, 8, 1) ............................................................................................................. 3-6
4. Choosing the Proper Operation Mode ................................................................................................ 4-1
Overview ........................................................................................................................................... 4-2
Real COM Mode .................................................................................................................................. 4-2
RFC2217 Mode ................................................................................................................................... 4-3
TCP Server Mode ................................................................................................................................ 4-3
TCP Client Mode ................................................................................................................................. 4-3
UDP Mode .......................................................................................................................................... 4-4
Pair Connection Mode .......................................................................................................................... 4-4
Ethernet Modem Mode ......................................................................................................................... 4-4
Reverse Telnet Mode ........................................................................................................................... 4-5
Disabled Mode .................................................................................................................................... 4-5
5. Web Console Configuration ............................................................................................................... 5-1
Opening Your Browser ......................................................................................................................... 5-2
Quick Setup ....................................................................................................................................... 5-3
Export/Import .................................................................................................................................... 5-6
Basic Settings .................................................................................................................................... 5-6
Network Settings ................................................................................................................................ 5-7
LLDP Settings ................................................................................................................................... 5-10
Serial Settings .................................................................................................................................. 5-10
Operating Settings ............................................................................................................................ 5-12
Real COM Mode ......................................................................................................................... 5-13
RFC2217 Mode .......................................................................................................................... 5-16
TCP Server Mode ....................................................................................................................... 5-18
TCP Client Mode ........................................................................................................................ 5-21
UDP Mode 5-................................................................................................................................ 25
Pair Connection Mode ................................................................................................................ 5-27
Ethernet Modem Mode ............................................................................................................... 5-29
Reverse Telnet Mode ................................................................................................................. 5-31
Disabled Mode .......................................................................................................................... 5-32
Accessible IP Settings........................................................................................................................ 5-33
Auto Warning Settings ....................................................................................................................... 5-34
Auto warning: Email and SNMP trap ............................................................................................ 5-34
Event Type ............................................................................................................................... 5-35
Upgrade Firmware ............................................................................................................................ 5-37
Monitor............................................................................................................................................ 5-37
Monitor Line ............................................................................................................................. 5-37
Monitor Async ........................................................................................................................... 5-38
Monitor Async-Settings .............................................................................................................. 5-38
Change Password ............................................................................................................................. 5-39
Load Factory Default ......................................................................................................................... 5-39
Save/Restart .................................................................................................................................... 5-40
NPort 5000AI M12 Series- Introduction
1-2
Overview
NPort is5000AI-M12 device server designed to make serial - devices network ready in an instant and is
compliant with standards, allowing them to perform reliably in rolling stock and -4 EN 50155 and EN 50121
wayside -applications where high level vibration is present. Use the NPort 5000AI M12 device servers to give
your PC software direct access to serial devices from anywhere on the network.
Package Checklist
Before installing the NPort 5000AI-M12 series device servers, verify that the package contains the following
items:
Standard Accessories
1 NPort 5000AI M12- serial device server
Documentation and Software CD
Quick Installation Guide (printed)
Warranty Card
Optional Accessories
DR- -45 24 45W/2A DIN-Rail 24 VDC Power Supply with universal 85 to 264 VAC input
DR- -75 24 75W/3.2A DIN- Rail 24 VDC Power Supply with universal 85 to 264 VAC input
DR- -120 24 120W/5A DIN-Rail 24 VDC Power Supply with 88 to 132 VAC/176 to 264 VAC input
DK- -TN 5308 DIN- Rail kit
NOTE: Notify your sales representative if any of the above items is missing or damaged.
Product Features
The NPort 5000AI- M12 Series are the world’s first EN 50155 compliant and includes:device servers
Speedy 3-step web- based configuration
COM port grouping and UDP multicast applications
Real COM/TTY drivers for Windows and Linux
Standard TCP/IP interface and versatile TCP and UDP operation modes
Compliant with EN 50121- 4 and essential sections of EN 50155
M12 connector and IP40 metal housing
2 KV isolation for serial signals
Product Specifications
Ethernet Interface
Number of Ports: 1
Speed:
10/100 Mbps, auto MDI/MDIX
Connector:
M12
Serial Interface
Number of Ports:
1/2/4
Serial Standards:
-RS 232/422/485
Connector:
DB9 male
Serial Line Protection:
15 KV ESD protection for all signals
RS
-485 Data Direction Control: ADDC® (automatic data direction control)
Serial Communication Parameters
Data Bits:
5, 6, 7, 8
NPort 5000AI M12 Series- Initial IP Address Configuration
3-3
Take the following steps to use ARP to configure the IP address:
1. Obtain a valid IP address for your NPort - 5000AI M12 from your network administrator.
2. Obtain the NPor MAC address from the label on t 5000AI M12- ’s its bottom panel.
3. Execute the ‘arp -s’ command - from your computer’s MS DOS prompt by typing:
–s arp 192.168.200.100 00-90- - - - E8 xx xx xx
This is where 192.168. .100 is the 200 new IP address and 00-90- - - - E8 xx xx xx is the MAC address for your
NPort .)5000AI M12- . (Be sure to use the actual IP address and MAC address for your NPort 5000AI M12-
4. Next, execute a special Telnet command by typing:
telnet 192.168.200.100 6000
After issuing this command, a Connect failed message will appear, as shown here. After the NPort reboots,
its IP address should be updated to the new address, and you can reconnect using Telnet, Web either , or
Administrator to check that the update was successful.
Telnet Console
Depending on how your computer and network are configured, you may find it convenient to use network
access to set up your NPort 5000AI M12- ’s IP address. This can be done using Telnet.
ATTENTION
Figures in this chapter were generated using
the NPort 5000AI M12- I.
1. From the Windows desktop, click on Start and then select Run.
2. Type telnet 192.168.127.254 (use the correct IP address if different from the default) in the Open text
input box, and then click OK.
3. When the Telnet window opens, if you are prompted to input the Console password, input the password and
then press Enter.
Note that this page will only appear if the NPort is password protected.
NPort 5000AI M12 Series- Web Console Configuration
5-3
4. The NPort 5000AI- M12 homepage will open next. There are two buttons on this page: Quick setup and
Export/Import. You can click Overview at any time to go back to this page. The following sections
introduce these two convenien functions and all other specific settings in the t the Main Menu on the left.
ATTENTION
If you can’t remember the password,
the ONLY way to configure the NPort 5000AI M12- is to load factory
defaults
- . by using the Reset to default button located at the top side of NPort 5000AI M12
Remember to
export the configuration file when you have finished the configuration. After using the
Reset to
default
button to load factory defaults, your configuration can be easily reloaded into the NPort 5000AI-
M12
with the
Import function.
ATTENTION
If your NPort
5000AI M12- application requires using password protection, you must enable the cookie
function in your browser. If the cookie function is disabled, you will not be allowed to enter the Web Console
Screen.
Quick Setup
Quick Setup streamlines configuration of your NPort into three basic and quick steps that covers the most
commonly-used settings. At any time while in Quick Setup you may click the button to return to the Back
previous step, or the button to reverse all settings. For more detailed settings, please refer to the Cancel
“Basic Settings,” “Network Settings,Serial Settings,” and “Operating Settings,” sections later in this chapter.
NPort 5000AI M12 Series- Web Console Configuration
5-5
In the Step 3/3, you can modify the serial settings.
Review your settings at the Finish Settings page to confirm that they are correct, and then click the
Save/Restart button to restart the device with the new settings.
Note that if you changed the IP address, you will not be able to return to the Home Page with the Home button.
NPort 5000AI M12 Series- Web Console Configuration
5-6
Export/Import
Export/Import allows you to back up and recover your settings.
Click Export to store all configuration data into a default file, <Servername>.txt. Click the Import button to
upload a configuration file to the NPort 5000AI M12- .
Basic Settings
Server name
Setting Factory Default Necessity
1 to 39 characters NP[model name]_[Serial No.] Optional
This option is useful for specifying the location or application of different NPort 5000AI- M12s.
Web/Telnet Console
The “Disable” option for “Web Console” and “Telnet Console” is included for security reasons. In some cases,
you may want to d cisable one or both of these onsole utilities as an extra precaution to prevent unauthorized
users from accessing your NPort 5000AI- c cM12. The factory default for both Web onsole and Telnet onsole is
Enable.
Web console
Setting Factory Default Necessity
Enable or Disable Enable Required
NPort 5000AI M12 Series- Web Console Configuration
5-18
TCP Server Mode
TCP alive check time
Setting Factory Default Necessity
0 to 99 min 7 min Optional
0 min: The TCP connection will not be closed due to an idle TCP connection.
1 to 99 min: The NPort 5000AI M12- automatically closes the TCP connection if there is no TCP activity for the
given time. closed, the NPort for another host After the connection is 5000AI- M12 start listenings ’s TCP
connection.
Inactivity time
Setting Factory Default Necessity
0 to 65535 ms 0 ms Optional
0 ms: TCP connection will not be closed due to an idle serial line.
1- - 65535 ms: The NPort 5000AI M12 automatically closes the TCP connection if there is no serial data activity
for the given time. After the connection is closed, the NPort 5000AI M12- start listenings for another host’s TCP
connection.
This parameter defines the maintenance status as Closed or Listen for the TCP connection. The connection is
closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time.
If the Inactivity time is set to 0, the current TCP connection is kept active until a connection close request is
received. Although Inactivity time is disabled, the NPort 5000AI- M12 will check the connection status between
the NPort 5000AI M12- and remote host by sending “keep alive” packets periodically. If the remote host does
not respond to the packet, assumes that the connection was closed down the NPort 5000AI M12-
unintentionally. The NPort will then force the existing TCP connection to clos5000AI- M12 e.


Product specificaties

Merk: Moxa
Categorie: Server
Model: NPort 5450AI-M12
Gewicht: 686 g
Soort serieële aansluiting: RS-232/422/485
Aantal Ethernet LAN (RJ-45)-poorten: 1
Certificering: CE, FCC, EN 55022 Class A, FCC Part 15 Subpart B Class A, EN 55024, EN 50155, EN 50121-4, IEC 60068-2-6
Ingangsspanning: 12 - 48 V
Ethernet LAN, data-overdrachtsnelheden: 10, 100 Mbit/s
Compatibele besturingssystemen: Windows 98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8 x86/x64, 2012 x64\r\nSCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac 10.3\r\nLinux kernel 2.4.x, 2.6.x, 3.x
Ondersteunde netwerkprotocollen: ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, IGMP V1/2, LLDP
Veiligheid: UL 60950-1, EN 60950-1
Datastroombeheer: Ja
Afmetingen (B x D x H): 80 x 216.6 x 52.9 mm
Seriële poort(en): 4
Bedrijfstemperatuur (T-T): -25 - 55 °C
RS-422 signalen: GND, RxD+, RxD-, TxD+, TxD-
RS-485 signalen: Data+, Data-, GND, RxD+, RxD-, TxD+, TxD-
RS-232 signalen: CTS, DCD, DSR, DTR, GND, RTS, Rx, Tx