1. Overview
The NPort 5200 Series of compact palm-sized device servers are
used to control RS-232 (NPort 5210/5230/5210-T/5230-T) or
RS-422/485 (NPort 5230/5232/5232I/5230-T/5232 T/5232I- -T)
serial devices over a TCP/IP- based Ethernet.
Note:
“-T” indicates an extended temperature model.
2. Package Checklist
Before installing NPort 5200, verify that the package contains the
following items:
• 1 NPort 5200 2- port Serial Device Server
• Documentation & Software CD
• NPort 5200 Series Quick Installation Guide
Optional Accessories
• DK- 35A
DIN- Rail Mounting Kit (35 mm)
• CBL- - RJ45M9 150
RJ45 (8-pin) to DB9 (M) cable, 150 cm
• CBL- - RJ45F9 150
RJ45 (8- pin) to DB9 (F) cable, 150 cm
• CBL- - RJ45M25 150
RJ45 (8-pin) to DB25 (M) cable, 150 cm
• CBL- - RJ45F25 150
RJ45 (8-pin) to DB25 (F) cable, 150 cm
• DIN-Rail Power Supply and Adapter
Notify your sales representative if any of the above items is
missing or damaged.
3. Hardware Introduction
The NPort 5200 series of device servers are used to control
RS-232/422/485 devices. NPort 5210/5210- -T has two 8 pin RJ45
ports, both for the RS-232 interface. NPort 5230/5230-T has one
10-pin terminal block, with 5 pins used for one RS-232 port, and 5
pins used for one RS-422/485 port. NPort
5232/5232I/5232 T/5232I- - -T have one 10 pin terminal block, with
5 pins used for one RS-422/485 port, and 5 pins used for another
RS-422/485 port.
Reset Button—Press the Reset button continuously for 5 sec to
load factory defaults: Use a pointed object, such as a straightened
paper clip or toothpick, to press the reset button. This will cause
the Ready LED to blink on and off. The factory defaults will be
loaded once the Ready LED stops blinking (after about 5 seconds).
At this point, you should release the reset button.
NPort 5200 LED Indicators (top panel)
LED
Name
LED
Color
LED Function
Ready
red
Steady on:
Power is on and NPort 5200 is
booting up.
Blinking:
Indicates an IP conflict, or DHCP
or BOOTP server did n
ot respond
properly.
green
Steady on:
Power is on and NPort 5200 is
functioning normally.
Blinking:
The device server has been
located by Administrator’s
Location function
off
Power is off, or power error condition exists.
Ethernet
orange
10 Mbps Ethernet connection.
green
100 Mbps Ethernet connection.
off
Ethernet cable is disconnected, or has a
short.
P1, P2
orange
Serial port is receiving data.
green
Serial port is transmitting data.
off No data is being transmitted or received
through the seri al port.
4. Hardware Installation Procedure
STEP 1: After removing NPort 5200 from the box, the first thing
you should do is connect the power adaptor. Connect the 12-30
VDC power line with NPort 5200’s terminal block, or connect the
DIN- Rail power supply with NPort 5200’s terminal block.
STEP 2: Connect NPort 5200 to a network. Use a standard
straight-through Ethernet cable to connect to a Hub or Switch.
When setting up or testing NPort 5200, you might find it
convenient to connect directly to your computer’s Ethernet port. In
this case, use a cross-over Ethernet cable.
STEP 3: Connect NPort 5200’s serial port to a serial device.
STEP 4: Placement Options
In addition to placing
NPort 5200 on a desktop
or other horizontal
surface, you may also
make use of the DIN
-
Rail
or Wall Mount options, as
illustrated here.
Wall Mount
DIN- Rail
– – – – – – 4 5 6
www.moxa.com/support
The Americas:
- - - - - - - +1 714 528 6777 (toll free: 1 888 669 2872)
Europe:
- - -0 +49 89 3 70 03 99
Asia-Pacific:
-2- - +886 8919 1230
China:
- - - - - - +86 21 5258 9955 (toll free: 800 820 5036)
2 . A r r . 201 Moxa Inc ll ights eserved
5. Software Installation Information
To install NPort Administration Suite, insert the NPort
Document & Software CD into your computer’s CD-ROM drive.
Once the NPort Installation CD window opens, click on the
Installation button, and then follow the instructions on the screen.
To view detailed information about NPort 5200 Administration
Suite, click on the Documents button, and then select “NPort
5200 Series User’s Guide” to open the pdf version of this user’s
guide. The PComm Lite program is also included in the
Documentation & Software CD free of charge. Install PComm
Lite to use the Serial Console for configuring the IP address for
the first time.
6. Pin Assignments and Cable Wiring—
NPort 5230/5230-T
Terminal Block Wiring
Note:
NPort 5232/5232I/5232-T/5232I-T have 2 RS-422/485 ports. The
pin assignments are the same as NPort -5230/5230 T’s port 2.
Refer to the “NPort 5200 Series User’s Manual” for more details.
7. Pin Assignments and Cable Wiring—
NPort 5210/5210-T
RJ45 (8-pin) Connector Pinouts
8- Pin
Signal
1
DSR
2
RTS
3
GND
4
TxD
5
RxD
6
DCD
7
CTS
8
DTR
Cable Wiring (RS-232)
Four cables are available as optional accessories that can be used
to connect NPort 5210/5210- -T to RS 232 serial devices. For your
convenience, we show precise cable wiring diagrams for each of
the four cables.
RJ45 (8-pin) to DB25 Female (Cable Name: CBL- - RJ45F25 150)
RJ45 (8-pin) to DB25 Male (Cable Name: CBL- - RJ45M25 150)
RJ45 (8-pin) to DB9 Female (Cable Name: CBL- - RJ45F9 150)
RJ45 (8-pin) to DB9 Male (Cable Name: CBL- -RJ45M9 150)
8. Specifications
Power requirements
NPort 5210/5210- T:
12 to 48 VDC, 305 mA at 12V (max.)
NPort 5230/5230- T:
12 to 48 VDC, 305 mA at 12V (max.)
NPort 5232/5232- T:
12 to 48 VDC, 359.6 mA at 12V (max.)
NPort 5232I/5232I- T:
12 to 48 VDC, 509.4 mA at 12 V (max.)
Operating temp.
F
or standard models
F - or T models
0
to 55◦C (32 to 131◦F)
- (- 40 to 75◦C 40 to 167◦F)
Operating humidity
5 to 95% RH
Dimensions (W×D×H)
NPort 5210/5230/5232/
5210
- -T/5230 T/5232-T
(including ears)
90 × 100.4 × 22 mm
(
3.54 × 3.95 × 0.87 in)
NPort 5210/5230/5232/
5210
- -T/5230 T/5232-T
(without ears)
67 × 100.4 × 22 mm
(
2.64 × 3.95 × 0.87 in)
NPort 5232I/5232I
-T
(including ears)
90 × 100.4 ×
35 mm
(3.54 × 3.95 ×1.37 ) in
NPort 5232I/5232I
-T
(without ears)
67 × 100.4 ×
35 mm
(2.64 × 3.95 × 1.37 ) in
Surge protection
15 KV ESD for serial port
Magnetic isolation
1.5 KV for Ethernet
Power line protection
4 KV Burst (
EFT) -4-4 , EN61000
2 KV Surge, EN61000-4-5
Regulatory approvals
FCC Class A Class A, CE , UL, CUL, TÜV
Product specificaties
Merk: | Moxa |
Categorie: | Server |
Model: | NPort 5210 |
Gewicht: | 320 g |
Stroomvoorziening: | 12/48 VDC, 305 mA |
LED-indicatoren: | Ja |
Connectiviteitstechnologie: | Bedraad |
Certificering: | EN 60601-1-2 B, EN55011 |
Interface: | RS-232 |
Aansluitingen: | 2 x RS-232 |
Temperatuur bij opslag: | -20 - 85 °C |
Luchtvochtigheid bij opslag: | 5 - 95 procent |
Veiligheid: | UL: UL60950-1, TÜV: EN60950-1 |
Mean time between failures (MTBF): | 134850 uur |
Maximale overdrachtssnelheid van gegevens: | 0.2304 Mbit/s |
Afmetingen (B x D x H): | 67 x 100.4 x 22 mm |
Elektromagnetische emissie: | CE: EN55022/EN55024 A, FCC: FCC 15 BA |
Bedrijfstemperatuur (T-T): | 0 - 55 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 95 procent |
Datalink-protocollen: | Ethernet, Fast Ethernet |
Heb je hulp nodig?
Als je hulp nodig hebt met Moxa NPort 5210 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Server Moxa
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
2 Augustus 2023
Handleiding Server
- Server HP
- Server Sony
- Server Asus
- Server Medion
- Server Toshiba
- Server Abus
- Server Acer
- Server Acti
- Server Allnet
- Server Apc
- Server Axis
- Server Buffalo
- Server D-Link
- Server Dell
- Server Digi
- Server Digitus
- Server Dual Bay
- Server Eaton
- Server Elac
- Server EMC
- Server Fantec
- Server Flir
- Server Freecom
- Server Fujitsu
- Server GeoVision
- Server Gigabyte
- Server Hikvision
- Server Ibm
- Server In Win
- Server Iomega
- Server Kathrein
- Server LaCie
- Server Lenovo
- Server LevelOne
- Server Linksys
- Server Luxman
- Server Maxdata
- Server Megasat
- Server Monacor
- Server MSI
- Server Nec
- Server Netgear
- Server Provision ISR
- Server QNAP
- Server Quantum
- Server Revox
- Server Seagate
- Server Sitecom
- Server Sun
- Server Synology
- Server Technics
- Server Trendnet
- Server Veritas
- Server Western Digital
- Server ZyXEL
- Server Conceptronic
- Server Atlona
- Server SilverStone
- Server Intel
- Server SIIG
- Server Tripp Lite
- Server Valcom
- Server Cisco
- Server Matrox
- Server Asustor
- Server Gefen
- Server Planet
- Server Intellinet
- Server Silex
- Server Supermicro
- Server G-Technology
- Server Lindy
- Server AVerMedia
- Server Black Box
- Server Blackmagic Design
- Server ATen
- Server Extron
- Server Areca
- Server AMX
- Server SEH
- Server StarTech.com
- Server HGST
- Server Sonnet
- Server TAIDEN
- Server Advantech
- Server Smart-AVI
- Server Kramer
- Server KanexPro
- Server Avocent
- Server Vimar
- Server Hanwha
- Server Ernitec
- Server MvixUSA
- Server Promise Technology
- Server Raidsonic
- Server Rocstor
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Middle Atlantic
- Server Mr. Signal
- Server Atlantis Land
- Server C2G
- Server Lantronix
- Server IStarUSA
- Server NETSCOUT
- Server Mobotix
- Server Origin Storage
Nieuwste handleidingen voor Server
30 Januari 2025
30 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
8 Januari 2025
18 December 2024
18 December 2024
9 December 2024