Master MAC-30P Handleiding

Master Ventilator MAC-30P

Lees hieronder de 📖 handleiding in het Nederlandse voor Master MAC-30P (15 pagina's) in de categorie Ventilator. Deze handleiding was nuttig voor 9 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/15
IMPORTANT: Read and understand all of the instructions in this manual before assembling,
starting, or servicing the fan. Improper use of this fan can cause serious injury. Keep this
manual for future reference.
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors. Never use the fan in spaces which
contain products such as gasoline, solvents, paint thinners, dust particles,
volatile or airborne combustibles, or any unknown chemicals.
Model Numbers:
MAC-24P, MAC-24POSC, MAC-30P, MAC-30POSC
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
CAUTION
THIS IS A FAN - NOT A TOY! TO REDUCE THE RISK OF PERSONAL
INJURY AND ELECTRIC SHOCK, FANS SHOULD NOT BE PLAYED
WITH OR PLACED WHERE SMALL CHILDREN CAN REACH IT.
To guard against electric shock while operating, do not allow fan to come in
contact with other grounded objects such as pipes, radiators, etc.
Risk of fire, electric shock, or personal injury when performing
service or maintenance. Unplug or disconnect the fan from the
power supply before servicing.
CAUTION: Automatically operated device - to reduce the risk of
injury disconnect from power source before servicing.
To reduce the risk of fire or electric shock, do not use this fan with
any solid- state speed control device.
Safety Information
WARNING
WARNING
WARNING
WARNING
WARNING
To Reduce The Risk Of Electric Shock And Injury To Persons, Do
Not Use In a Window.
Do not operate any fan with a damaged cord or plug. Discard fan or
return to an authorized service facility for examination and/or repair.
Do not run cord under carpeting. Do not cover cord with throw rugs,
runner, or similar coverings. Do not route cord under furniture or appliances. Arrange cord
away from traffic areas and where it will not be tripped over.
WARNING
WARNING
'
(
7
6
,
/
&0
86&
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
© 2019 Pinnacle Climate Technologies, Inc. MAVD-418
User’s Manual &
Operating Instructions
HIGH VELOCITY
FAN
WARNING: This product can expose you to chemicals including lead,
which is known to the State of California to cause cancer and birth
defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov.
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
OR WHILE CONNECTED TO A POWER SOURCE
© 2019, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
2
- Before operating always check fan for loose
or damaged parts. Inspect power cord for any
damage. Never use fan if any parts are
damaged or missing. Never use fan without
safety guards attached.
- Operate only on 120 volt 60 Hz (cycle) current
with a minimum of a 15 amp circuit.
- When used with an extension cord, use only
cord of proper size (Amp rating), UL listed, and
with receptacle to accept three prong grounded
plug furnished on the fan’s power cord. Always
keep power cord and extension cords away
from heat, oil, and sharp edges. Inspect cords
periodically and replace if damaged.
Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and regulations.
When servicing or replacing a component requires the removal or
disconnection of a safety device, the safety device is to be reinstalled or
remounted as previously installed before operating this fan.
Use this fan only in the manner intended by the manufacturer. If you have
any questions, contact Customer Service at 800-641-6996.
WARNING
WARNING
WARNING
'
(
7
6
,
/
&0
86&
30P
24"/30" Pedestal Fan
30POSC
24POSC
24P
To Reduce The Risk Of Electric Shock, Do Not Expose To Water Or
Rain. This unit is designed for indoor use only.
WARNING
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING
OR WHILE CONNECTED TO A POWER SOURCE
© 2019, Pinnacle Climate Technologies, Inc. High Velocity Fan User’s Manual
3
24" & 30" PEDESTAL FANS: 24P / 24POSC / 30P / 30POSC
Installation and Assembly
Tools Needed:
Pliers
Phillips head screwdriver
Flat head screwdriver
Adjustable wrench
Parts Included In Box:
(1) Base
(1) Front Guard
(1) Rear Guard
(1) Motor Assembly
(1) Fan Blade Assembly
(1) Locking Collar
(1) Upper Support Pole
(1) Lower Support Pole
(1) Support Pole Spring
Bag of hardware
1. Remove the base from rear guard. Keep the (2)
screws holding the base to the rear guard. These
screws will be used to connect the base and lower
support pole
.
2. Place the fan base on level ground.
3. Loosen the locking collar on the support pole using
the provided Allen wrench (hex wrench). Extract the
upper support pole slowly to adjust the height of the
fan. The support pole must be fully extended before
the spring is placed inside. Place the spring into the
bottom of the upper support pole.
4. Place the support pole plug into the bottom of the
upper support pole to secure spring in the upper
support pole.
5. Mount entire support pole to the base. Align holes
and use (3) screws from the hardware bag and the
(2) screws from Step 1 to secure the entire support
pole to the base.
6. Push down the base cover over the base support
bolts.
7. Mount the motor assembly to the connector on the
upper support pole (see Figure 1). Make sure the
holes align.
8. Secure motor assembly with Pivot Bolt and Nut.
Tighten the nut and bolt firmly using the wrench.
9. Slide the rear guard onto the motor assembly and
secure it with (4) flange screws (screws from the
motor). See Figure 2. Tighten the screws firmly
using the wrench.
10. Loosen the screw on the back of the fan blade
assembly using the Allen wrench (Hex Wrench).
Slide the fan blade assembly onto the motor shaft.
11. Tighten the screw on the back of the fan blade
assembly using the Allen wrench onto the flat part of
the fan shaft.
12. Attach the front guard to the rear guard and secure
with the fasteners on the front guard.
Figure 2: Attaching Rear Guard to Motor
Rear Guard
Motor
Motor Assembly
Pivot Bolt
Nut
Upper Support Pole
Figure 1: Attaching Motor to Motor Support Assembly
Do NOT slide fan
blade screw beyond
the groove on
the shaft! This will cause the fan blade to spin
improperly, damaging the fan! Be sure that fan
shaft is flush with front of fan blade assembly.
CAUTION
NOTE: This model CAN NOT be wall mounted


Product specificaties

Merk: Master
Categorie: Ventilator
Model: MAC-30P

Heb je hulp nodig?

Als je hulp nodig hebt met Master MAC-30P stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Master

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator

Ufesa

Ufesa Montreal Handleiding

11 September 2024
DeWalt

DeWalt DXF1645 Handleiding

11 September 2024
Ufesa

Ufesa Helsinki Handleiding

11 September 2024
Ufesa

Ufesa Riga Handleiding

11 September 2024
Ufesa

Ufesa Oslo WiFi Handleiding

11 September 2024
Ufesa

Ufesa Göteborg Handleiding

11 September 2024
Ufesa

Ufesa Dakota Handleiding

11 September 2024