Manson NTP-5521 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Manson NTP-5521 (5 pagina's) in de categorie Batterij-oplader. Deze handleiding was nuttig voor 16 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
NTP- / /5561 SWITCHING MODE POWER SUPPLY 5521 5531
USER MANUAL
Keep this manual in a safe place for quick reference at all times.
This manual contains important safety and operation instructions for correct use of the power
supply. Read through the manual and pay special attention to the markings and labels of this
unit and equipment to be connected.
Pay special attention to these two types of notices used in this manual
WARNING:
Failure to observe this warning may cause injury to persons and damage to power
supply or connected equipment.
CAUTION:
Failure to observe this warning may result in damage to equipment
and Improper functioning of the power supply.
WARNING:
1. Do not use this power supply near water.
2. Do not operate or touch this power supply with wet hands.
3. Do not open the casing of the power supply when it is connected to ac mains.
4. Refer all servicing to qualied service personnel only.
5. Before replacing the AC fuse at AC socket, nd out and clear up the cause rst.
6. Replace the AC fuse with the same type and rating as the original fuse.
7. The max. output voltage of Model NTP- is 60VDC, avoid touch the metal contact part of the 5561
output terminals.
CAUTION:
1. Use a grounded 3 pin AC source.
2. This unit is for indoor use only.
3. Do not operate or place this unit in a humid, dusty, in direct sunlight location or near any heat source.
4. Before plugging into local AC mains, check with the rating label at the back of the unit.
5. Do not block any ventilation openings of the unit.
6. This unit must be used within the specied rating, regular excessive continuous loading may cause
damage to the power supply.
7. The gauge size of input power cable must be at least 0.75mm
2 and the total length of power cable
must not exceed 3m.
OPERATION ENVIRONMENTAL CONDITION
-80% R.H. 10
Maximum relative humidity 80% for temperature up to 31°C decreasing linearly to 50% relative humidity at
40°C.
Altitude up to 2000m
Installation category: CAT 2
Pollution degree: 2
Mains supply voltage fluctuation up to ±10% of the normal voltage
INTRODUCTION
This series of 100W Switching Mode Power Supplies with Current Limiting Control is designed with the objectives
of high accuracy, compactness and easy portability. Rotary encoder tuning with MCU are used for voltage and
current control. 4 digit display LCD of voltage and current for high precision.
This power supply is ideal for trouble shooting circuit boards or devices which require two or three dierent input
voltages such as 3V or 5V, 12V and 1-36V. This power supply can provide 3 outputs at the same time.
All three outputs are fully isolated so dierent cross connections of 2 or 3 outputs can provide various fixed or
variable output voltages. Any output can be connected for positive or negative polarity. (See connection diagrams)
CONTROLS AND INDICATORS
1. Power Switch:
- Turns the power supply on o, when it is on the front display lights up.
2. AC Input Socket with Fuse
3. Concealed Fuse box (ply open the cover to get to the fuse)
4. 3.3V/5VDC selection switch (for Aux output 1)
5. Output Voltage Tuning knob. (Quick push the knob to toggle the coarse and ne tuning)
6. Output Current Tuning knob. (Quick push the knob to toggle the coarse and ne tuning)
7. Output On/O push button
- For Main output: Quick push this button to turn the Main output ON/OFF
- For Main output & Aux outputs: Push and hold this button for 3 seconds to turn the Main and Aux outputs
OFF, quick push this button again to turn them ON
8. Main Output Terminal Positive (+) Red color.
9. Main Output Terminal Negative (-) Black color
10. Aux Output 1 Terminal Positive (+ Red color (3.3VDC or 5VDC selectable) )
11. Aux Output 1 Terminal Negative (-) Black color (3.3VDC or 5VDC selectable)
12. Aux Output 2 Terminal Positive (+ Red color (Fixed 12VDC) )
13. Aux Output 2 Terminal negative (- Black color (Fixed 12VDC) )
14. LCD Display panel showing:
- 4 digit voltmeter meter, (CV) constant voltage mode, (CC) constant current mode, , Am
- Output Terminal on/o state
- 2 digit Aux outputs Ammeter
15. Aux 1 output voltage indicator
16. Reserved (factory internal use only)
17. Ground Terminal
OPERATIONS
Basic Mode of Operation
This power supply is designed to operate as a constant voltage source or as a constant current source. Automatic
crossover to either mode of operation occurs when the load condition changes as following:
Constant Voltage (CV), Automatic crossover & Constant Current (CC)
The power supply functions as a constant voltage source (CV) as long as the load current is less than the preset
current limiting value. When the load current is equal to or greater than the preset current limiting value, the power
supply will automatically cross over to the constant current mode, voltage will drop, (CC) will show on the LCD
display panel and it will operate as a constant current source.
When the load current drops below the preset current limiting value, the supply returns to constant voltage (CV)
mode.
Set the Output Voltage and Presetting Current Limiting Value (CC)
Turning the voltage or current knob to set your desired values.
Quick pushes on the knobs will move the decimal place for fast tuning.
Turn the knob when the desired number column isashing otherwise you need to repeat quick pushes again.
One quick push on the current knob to see the preset current limiting value.
Aux. voltage selection output 1
Move the switch (4) at the back of power supply for selection of 3.3 or 5 VDC.
At 3.3VDC setting, indicator (15) is O
and at 5VDC setting indicator (15) is On.
Connection and Operation Procedure
1. and Check the rating label plug in to AC mains.
2. Switch on the power supply and the LCD display should be on at the same time.
3. The (CV) icon should be shown on the display.
4. Turn to current volume knob (6) to maximum clockwise if you do not require lower Current limiting value,
otherwise do the preset the (CC) limiting procedure.
5. Set your desired output voltage and then turn o the output terminal by push button (7).
6. Connect to your load positive to positive and negative to negative.
7. Turn on the output terminal again and check if display shows (CV).
8. If display shows (CC), either your preset current limiting value is too low or your load requires more voltage and
current. You need to re-access the voltage and current requirement of your load and increase the voltage or
current accordingly until (CV) appears.
Connecting the 3 outputs (using NTP -5531, 1-36V, 0.25-3A as an example)
All the three outputs are fully isolated from ground and with each other so that it is possible to make cross
connections to power a circuit board or device that requires for example: +3 or +5V, +12 V or -12V and 1-36V as
shown in Fig. 1.
The variable main output is set for 12V and it is assigned as the +12V source (available maximum current 3A)
Note the variable main output can be set for other voltage (1-36V) such as 16V.
The xed 12V is made as the - 12V source (available maximum current 0.5A)
The xed 5V is made as the +5V source. (available maximum current 0.5A)


Product specificaties

Merk: Manson
Categorie: Batterij-oplader
Model: NTP-5521

Heb je hulp nodig?

Als je hulp nodig hebt met Manson NTP-5521 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Batterij-oplader Manson

Manson

Manson HCS-3202 Handleiding

16 Augustus 2023
Manson

Manson NTP-5561 Handleiding

16 Augustus 2023
Manson

Manson NEP-8323 Handleiding

16 Augustus 2023
Manson

Manson SDP-3660 Handleiding

16 Augustus 2023
Manson

Manson NTP-5631 Handleiding

16 Augustus 2023
Manson

Manson HCS-3102 Handleiding

16 Augustus 2023
Manson

Manson SDP-3636 Handleiding

16 Augustus 2023
Manson

Manson NTP-5521 Handleiding

16 Augustus 2023

Handleiding Batterij-oplader

Nieuwste handleidingen voor Batterij-oplader