HCS-3100/3102/3104
Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control
User Manual
1. INTRODUCTION
This family of efficient , upgraded SMPS with small form factor, auto cross over CV CC, 3 VI presets, remote control
offers unique solution for various loading conditions and applications.
The dual action (coarse/fine tune) rotary encoder tuning with MCU makes setting the voltage and current levels ever so
smooth, precise and fast. Setting, changing, and checking the current limit level can be done easily without sparking the
output poles.
The remote control functionality allows the output power on/off, voltage &current be adjusted without touching the front
panel of the power supply.
The USB port is added for access to computer to run cyclical operation with max. 20 programmable sets of preset of
voltage and current with different time duration and up to 999 cycles.
It is suitable for a wide range of applications such as laboratory, telecommunication, production testing, field test of
voltage critical distant load, powering of dc network and etc...
The 3 user defined presets facilitate quick access to frequently used VI settings.
2. WARNING
• Do not use this power supply near water.
• Do not operate or touch this power supply with wet hands.
• Do not open the casing of the power supply when it is connected to ac mains.
• Refer all servicing to qualified service personnel only.
• Before replacing the AC fuse at AC socket , find out and clear up the cause first.
• Replace the AC fuse with the same type and rating as the original fuse.
• The max. output voltage of Model HCS-3104 is over 60VDC, avoid touch the metal contact part of the output
terminals.
3. CAUTION
• Use a grounded 3 pin AC source.
• This unit is for indoor use only.
• Do not operate or place this unit in a humid, dusty, in direct sunlight location or near any heat source.
• Before plugging into local AC mains, check with the rating label at the back of the unit.
• Do not block any ventilation openings of the unit.
• This unit must be used within the specified rating, regular excessive continuous loading may cause damage to the
power supply.
• The gauge size of input power cable must be at least 0.75mm
2 and the total length of power cable must not exceed
3m.
4. O PERATION ENVIRONMENTAL CONDITION
• 10-80% R.H.
• Altitude up to 2000m
• Installation category: CAT 2
• Pollution degree: 2
• Mains supply voltage fluctuation up to ±10% of the normal voltage
5 . CONTROLS AND INDICATORS
(1) LED panel meter display with CC/CV Indictor
(2) Rear Control Indicator (lights up when using Preset/ Remote Control/ Set mode)
(3) Output Voltage Control Knob (control both the main and auxiliary output voltage)
(4) Output Current Control Knob (control both the main and auxiliary output current limit)
(5) Power ON/OFF Switch
(6) Aux. output terminal (max 5A)
Note: HCS-3100: The total rated current (Aux.+Main) is 10A
HCS-3102: The total rated current (Aux.+Main) is 5A
HCS-3104: The total rated current (Aux.+Main) is 2.5A
(7) Output Terminal (Rated 10A for HCS-3100/ Rated 5A for HCS-3102/ Rated 2.5A for HCS-3104)
(8) Mode Selection Switch (Normal, Preset, Remote Control, Set Modes)
(9) Recall Selection Switch
(10) Remote Control Terminal
(11) Cooling Fan Air Intake Grille
(12) AC Input Plug
(13) USB port
(for access to computer to run cyclical operation with programmable voltage, current, period time and cycle)
Front
Rear
6. CONTROL MODE SELECTION
There are 4 modes, Normal, Preset, Set and Remote Control mode for the power supply.
Slide the Mode Selection Switch (8) to your desired Mode.
The power supply is factory preset to Normal Mode with maximum current level CC.
6.1 Normal Mode
This is the factory preset mode and the power supply output V, I are controlled by the dual action volume knobs.
Push the knobs to toggle the coarse and fine tuning, notice the subtle changes in brightness of related LED. .
Adjust the knobs to your desired values by trying coarse and fine tuning .
To check the preset current level , just turn the Current Knob lightly in any direction .
The display will resume its normal brightness after few seconds to double confirm your adjustment.
6.2 Preset Mode
a. In this mode , the Rear Control Light is on to indicate panel V & I controls are de-activated.
b. There are 3 preset output P1/ P2/ P3 at the Recall Selection Switch (9)
c. The preset values are factory set as following table.
d. End user can set his own output rating, please refer to paragraph 6.3
Recall No. Output Voltage Output Current
P1 5V Maximum
P2 13.8V Maximum
P3 HCS-3100: 15V
HCS-3102: 25V
HCS-3104: 55V
Maximum
6.3 Set Mode – First enter into the Set Mode by pushing Switch (8) to Set Mode slot.
The power supply is then ready to be preset.
6.3.1 To define the preset output P1/ P2/ P3.
a. Select the Recall Switch (9) to the position P1, P2 or P3 which you want to set
b. Adjust the front panel voltage control knob to set your desired voltage value
c. Adjust the front panel current control knob to set your desired current limit value
d. Repeat the procedure for remaining recalls P1, P2, P3 if desired.
e. Move Mode Switch (8) from Set to Preset position to confirm your settings.
Remarks:
All the set values in the presets will be kept even after the power supply has been tuned off.
Always check output voltage of Presets before connect to Load
To check the preset values, move Mode Switch (8) to Preset position
Move the Recall Switch (9) to P1, P2 or P3.
The V and I settings of corresponding RECALL P1 ,P2 ,P3 will be show on the panel meters .
6.3.2 To reset the unit back to factory setting
a. Turn OFF the power supply
b. Push and hold both front panel voltage and current control knobs at the same time
c. Turn ON the power supply again
d. Release front panel voltage and current control knobs
6.4 Remote Control Mode
To control the output voltage and current by remote control connector (10)
Please refer to paragraph 8


Product specificaties

Merk: Manson
Categorie: Batterij-oplader
Model: HCS-3102

Heb je hulp nodig?

Als je hulp nodig hebt met Manson HCS-3102 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Batterij-oplader Manson

Manson

Manson HCS-3202 Handleiding

16 Augustus 2023
Manson

Manson NTP-5561 Handleiding

16 Augustus 2023
Manson

Manson NEP-8323 Handleiding

16 Augustus 2023
Manson

Manson SDP-3660 Handleiding

16 Augustus 2023
Manson

Manson NTP-5631 Handleiding

16 Augustus 2023
Manson

Manson HCS-3102 Handleiding

16 Augustus 2023
Manson

Manson SDP-3636 Handleiding

16 Augustus 2023
Manson

Manson NTP-5521 Handleiding

16 Augustus 2023

Handleiding Batterij-oplader

Nieuwste handleidingen voor Batterij-oplader