La Crosse Technology 513-85647 Handleiding
La Crosse Technology
Klok
513-85647
Lees hieronder de 📖 handleiding in het Nederlandse voor La Crosse Technology 513-85647 (2 pagina's) in de categorie Klok. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
EXECUTIVE
ATOM I C CLOCK 3.0
MODEL: 51321867 5131429BL
POWER UP
WWVB ATOMIC TIME SIGNAL
1. Install 2 “AA” batteries into your Outdoor Sensor.
2. Insert the 5V power cord into an outlet, then into
your Atomic Clock. Optional: Insert 6 AA batteries
for backup. Power cord is required for Note:
constant backlight.
3. Once the sensor is reading to your clock, place
it outside in a shaded location to protect it from
the sun’s heat. See our mounting information:
bit.ly/temp_mounting
• The station will automatically search for the Atomic
Time Signal at power up and again at UTC 7:00,
8:00, 9:00, 10:00, and 11:00.
• Press and release the button to manually search
for the WWVB Atomic Time Signal.
• The Tower Icon will flash while searching, and be
solid on screen when the signal is received.
• For information about WWVB Atomic Time visit:
bit.ly/AtomicTime
TX141TH-Bv3
Outdoor Sensor
513-21867
(513-1429BL)
Atomic Clock
SETTINGS
TIME ZONES
ATLANTIC
EASTERN
CENTRAL
MOUNTAIN
PACIFIC
ALASKA
HAWAII
1. Hold the button to enter the Settings Menu.
2. Use the + or - button to adjust values.
3. Press the button to confirm and move to next
item.
4. Press the button at any time to exit.
Settings order:
• Language (English, Spanish, French, German)
• Beep ON/OFF
• Atomic ON/OFF
• DST AUTOMATIC/ DST ALWAYS OFF / DST ALWAYS ON
(Change Spring/Fall) (No change in Spring) (No change in Fall)
• Time Zone
• 12/24 Time Format
• Hour
• Minutes
• Year
• Month
• Date
• Month/Date or Date/Month
• Fahrenheit/Celsius
Language: The language selected in this menu will adjust
the Weekday readout and menu items.
Atomic OFF: If Atomic OFF is selected, menu will skip DST
and Time Zone settings and move straight to the 12/24
Hour Format setting.
Weekday: The Weekday sets automatically when Year,
Month and Date are set.
AD JUSTABLE BACKLI GHT
When using the power cord, press the button to
adjust your backlight brightness. There are 4 levels
plus an o option.
BUTTON FUNCTIONS
Press to search for Atomic Time Signal.
Hold to enter Settings Menu.
+ (PLUS) Settings: Press to adjust settings. Hold to adjust quickly.
Hold to search for Add-on Sensor.
- (MINUS) Settings: Press to adjust settings. Hold to adjust quickly.
Press to switch between Desired Time or Local Time.
Hold to adjust your Desired Time hour.
Press to adjust the information displayed: Time, Desired Hour,
Temperature... etc. The Auto-Scroll Icon will show when active.
Press to select Calendar Display.
Press to Adjust Backlight.
Settings: Press to exit Settings Menu.
DESIRED H O U R ( TIME AD JUST)
Have your clock match other times around the
world by setting a Desired Hour, kept accurate by
the Atomic time signal. only the hour can be Note:
changed.
Set Desired Hour:
1. Hold the button until the Hour flashes, “
Desired
Hour
” will show.
2. Press the + (PLUS) button to adjust the hour. Press
the - (MINUS) button to reset hour to “Local Time”.
3. Press the button to confirm and exit.
Switch between Desired Time and Local time:
• Press the button to switch between Desired
Time and Local Time.
• Desired Time is indicated with the icon.
Note: In the event of battery change or reset, these
settings will need to be readjusted.
VIEW LOCAL TIMESET DESIRED HOUR VIEW DESIRED HOUR
CALENDAR D I SPLAY OPTIONS
Press the button to change how the Calendar is
displayed. Full Weekday, Month/Date/Year, Weekday/
Month/Date.
CUS TO M TIME / T EMP E RAT U RE D ISP LAY
Press the button to adjust the data displayed on
screen. When the Auto-scroll Icon is showing, the
clock will switch between these options every 5
seconds.
TIME TEMPERATUREDESIRED HOUR
SEARCH FOR OUTDOOR SENSOR
If you are seeing NO or dashes for your outdoor readings,
please try the following steps:
1. Hold the Plus (+) button to search for your outdoor sensor.
The Reception Indicator will begin to animate.
2. If after 3 minutes the sensor still isn’t connected, bring
the sensor inside and remove power cord and batteries
from both the sensor and clock.
3. Press any button on the clock 20 times and leave the
parts sit for a few moments with the power o.
4. Install a new set of alkaline batteries into the sensor, then
insert the power cord and battries into your clock.
For additional help visit: bit.ly/basic_restart
5. If your outdoor data is still not appearing after these
steps, please contact our support sta via the links on the
next page.
CUSTOM DISP LAY O P TIONS
SPECIFICATIONS
Atomic Clock 513-21867 (513-1429BL):
Temperature Range: 32°F to 122°F (0°C to 50°C)
Humidity Range: 10% RH to 99% RH
Power Requirements: 6 “AA” (LR6, IEC) batteries (not included)
Battery Life: Over 24 months with reputable batteries.
Dimensions: 17.44” L x 11.73” H 1.22” W x
(44.3cm L x 29.8cm H x 3.1cm W)
Outdoor Sensor (TX141TH-Bv3)
Temperature Range: -40°F to 140°F (-40°C to 60°C)
Transmission Range: Over 330 ft. open air (100 meters) RF 433MHz
Update Interval: About every 51 seconds
Power: 2-AA, IEC, LR6 batteries (not included)
Battery Life: Over 12 months
Dimensions: 1.57” L x 0.79” W x 5.12” H (4.0 L x 2.0 W x 13.0 H cm)
WARR ANT Y IN FO
La Crosse Technology, Ltd. provides a 1-year limited time warranty
(from date of purchase) on this product relating to manufacturing
defects in materials & workmanship.
La Crosse Technology, Ltd, 2830 S. 26th St., La Crosse, WI 54601
For Full Warranty Details, Visit:
www.lacrossetechnology.com/pages/warranty
FCC S TAT EME NT
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
CAUTION!
Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
All rights reserved. This manual may not be reproduced in any
form, even in part, or duplicated or processed using electronic,
mechanical or chemical process without the written permission of
the publisher.
This booklet may contain errors or misprints. The information
it contains is regularly checked and corrections are included
in subsequent editions. We disclaim any responsibility for any
technical error or printing error, or their consequences.
All trademarks and patents are recognized.
If you require additional support, get in touch with our
friendly customer support team based out of
La Crosse, WI.
Phone: 1-608-782-1610
Online: bit.ly/contact_techsupport
Our knowledgeable customer support team is
available Monday-Friday, 8am-6pm CST.
WE’RE HERE TO HELP!
CA WARNING:
This product can expose you to chemicals including
acrylonitrile, butadiene, and styrene, which are known to
the State of California to cause cancer and birth defects or
other reproductive harm.
For more information, go to: www.P65Warnings.ca.gov
Ask questions, watch setup videos, and provide
feedback on our social media outlets: Facebook,
Instagram, You Tube and Twitter.
JOIN THE CONVERSATION
CAR E + MAINTENANCE
Battery replacement instruction:
When batteries of dierent brand or type are used together, or
new and old batteries are used together, some batteries may be
over-discharged due to a dierence of voltage or capacity. This
can result in venting, leakage, and rupture and may cause personal
injury.
• Always purchase the correct size and grade of battery suitable
for the intended use.
• Always replace the whole set of batteries at one time, taking
care not to mix old and new ones, or batteries of dierent types.
• Clean the battery contacts and those of the device prior to
battery installation.
• Ensure the batteries are installed correctly with regard to polarity
(+ and -).
• Remove batteries from product during periods of non-use.
Battery leakage can cause corrosion and damage to this
product.
• Remove used batteries promptly.
• For recycling and disposal of batteries, and to protect the
environment please check the internet or your local phone
directory for local recycling centers and / or follow local
government regulations.
Product specificaties
Merk: | La Crosse Technology |
Categorie: | Klok |
Model: | 513-85647 |
Heb je hulp nodig?
Als je hulp nodig hebt met La Crosse Technology 513-85647 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Klok La Crosse Technology
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
19 November 2024
19 November 2024
19 November 2024
15 November 2024
Handleiding Klok
- Klok Braun
- Klok IKEA
- Klok Casio
- Klok Fysic
- Klok Xiron
- Klok Accusplit
- Klok Ade
- Klok Alecto
- Klok Amplicom
- Klok Ascot
- Klok Audiovox
- Klok Auriol
- Klok Balance
- Klok Balance Time
- Klok BBrain
- Klok Dexford
- Klok Digi-tech
- Klok Ecom
- Klok Elro
- Klok Eurochron
- Klok Fisher Price
- Klok Geemarc
- Klok Gingko
- Klok Gira
- Klok Global Tronics
- Klok GlobalTronics
- Klok Glunz
- Klok Hager
- Klok Hama
- Klok Hermle
- Klok IHome
- Klok Irox
- Klok Karlsson
- Klok Kogan
- Klok Konig
- Klok Krontaler
- Klok La Crosse
- Klok Lenovo
- Klok Lexon
- Klok Livoo
- Klok Lorus
- Klok Lydion
- Klok Marquant
- Klok Mebus
- Klok Mondaine
- Klok Muse
- Klok Nedis
- Klok Perel
- Klok Profile
- Klok Ranex
- Klok RCA
- Klok Salter
- Klok Sempre
- Klok Taylor
- Klok Techno Line
- Klok Technoline
- Klok TFA
- Klok Tronic
- Klok United Office
- Klok Velleman
- Klok Ventus
- Klok Vitek
- Klok Weinberger
- Klok Jacob Jensen
- Klok Jung
- Klok Oregon Scientific
- Klok McIntosh
- Klok Camry
- Klok ECG
- Klok EMOS
- Klok Cresta
- Klok Citizen
- Klok Trevi
- Klok Zuiver
- Klok Chacon
- Klok Valcom
- Klok Dormakaba
- Klok AcuRite
- Klok ART
- Klok AV:link
- Klok Elation
- Klok ASA
- Klok TFA Dostmann
- Klok Antelope Audio
- Klok Equity
- Klok DB Technologies
- Klok Focus Electrics
- Klok Pyramid
- Klok CyberData Systems
- Klok Electronics International
- Klok Antelope
- Klok Bearware
Nieuwste handleidingen voor Klok
14 December 2024
14 December 2024
14 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024