La Crosse Technology 513-1211A Handleiding
La Crosse Technology
Klok
513-1211A
Lees hieronder de 📖 handleiding in het Nederlandse voor La Crosse Technology 513-1211A (4 pagina's) in de categorie Klok. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/4
Model: 513 1211/513 1211A- - www.lacrossetechnology.com/support Page | 1
Model: 1211.513 1211A513- -
Instruction Manual
DC: 081114
ATOMIC DIGITAL CLOCK
FRONT
VIEW
FOLDOUT
LEG
STAND
Battery
Compartment
3 “AA”
Time + Alarm
Calendar + Indoor Temperature
BACK
VIEW
TIME ZONE
SELECTOR
BUTTONS
Time Zone Indicator
Model: 513 1211/513 1211A- - www.lacrossetechnology.com/support Page | 2
TIME ZONES
PST Pacific
MST Mountain
CST Central
EST Eastern
GET STARTED
Step 1: Use the time zone selector (on back) to choose your time zone.
Step 2: Insert 3 AA batteries (not included) into the clock. Observe the new
correct polarity.
Restart: If there is no indoor temperature data after 60 seconds remove ,
batteries from the clock and press a button 20 times. After15 minutes, return to
Step 1 above.
SET TIME, DATE AND TEMPERATURE
1. Hold the button to enter time set mode. SET
2. Press the WAVE/+ DST/ or - buttons to adjust values.
3. Press the button to confirm and move to the next item.SET
TIME SET ORDER:
1. 12/24 hour time format
2. Hour
3. Minutes
4. Year
5. Month
6. Date
Press the button to exit, or SET wait 20 seconds without pressing buttons to
return to the normal time display.
DAYLIGHT SAVING TIME SETTING
Hold the button for 3 seconds to select DST on or o. DST
The DST icon appears in above the seconds when DST is on.DST
TIME ZONE SELECTION
Slide the time zone selector bar on the back of the clock to
choose the time zone for your area.
FAHRENHEIT/CELSIUS
Hold the button for 3 seconds to select Fahrenheit or Celsius °C/°F
temperature readings.
SET TIME ALARM
Press the button once to enter Alarm Mode. The letters will show in the SET AL
seconds display.
1. Hold the button for 3 seconds to enter alarm time set SET
mode.
2. Press the WAVE/+ DST/ or - buttons to adjust values.
3. Press the button to confirm and move to the next item.SET
Alarm Time setting order: 1. Hours, 2. Minutes
Model: 513 1211/513 1211A- - www.lacrossetechnology.com/support Page | 3
Alarm
Bell Icon
Snooze
Icon
ACTIVATE/DEACTIVATE TIME ALARM
Press the button once to view alarm time.SET
Press the WAVE/+ DST/ or - buttons to activate the alarm.
Once activated, the bell icon appears.
Press the WAVE/+ DST/ or - buttons to deactivate the alarm.
The bell icon will disappear.
SNOOZE (SILENCES ALARM TEMPORARILY)
When alarm sounds, press the button to silence the SNOOZE
alarm for 5 minutes. The alarm icon will flash.
In snooze mode, press any button to stop alarm for one day.
Note: The alarm will sound for 2 minutes and then shut off completely.
MANUAL WWVB RADIO CONTROLLED (ATOMIC) TIME SEARCH-
Press the WAVE/+ button to start or stop a manual signal search. WWVB
Icon will flash when searching.
For information about WWVB visit:
www.nist.gov/pml/div688/grp40/wwvb.cfm
ATOMIC SIGNAL SEARCH: The clock will search every 2 hours until the WWVB
time signal is received. After reception, this clock will only search for the atomic
signal after midnight.
ATOMIC CLOCK CARE AND MAINTENANCE
Do not mix old and new batteries
Do not mix Alkaline, Standard, Lithium or Rechargeable Batteries
Always purchase the correct size and grade of battery most suitable for intended use.
Replace all batteries of a set at the same time.
Clean the battery contacts and also those of the device prior to battery installation.
Ensure the batteries are installed with correct polarity (+and -).
Remove batteries from equipment which is not to be used for an extended period.
Remove expired batteries promptly.
Do not expose to extreme temperature, vibration or shock.
Clean with a soft damp cloth. Do not use solvents or scouring agents.
The clock is not a toy. Keep it out of reach of children.
The clock is not to be used for medical purpose or for public information. It is intended
for home use only.
The specs of this clock may change without prior notice.
Improper use or unauthorized opening of housing voids warranty.
If the clock is not working properly, change the batteries.
SPECIFICATIONS
Temperature Range: +14 to +122 °F (- 10 to +50 °C)
Power: 3 AA, IEC, LR6 batteries (not included)-
Dimensions: 10.75" x 1.38" x 16.75" (273.05 x 30.052 x 425.45 mm)
WWVB
Atomic Icon
Product specificaties
Merk: | La Crosse Technology |
Categorie: | Klok |
Model: | 513-1211A |
Heb je hulp nodig?
Als je hulp nodig hebt met La Crosse Technology 513-1211A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Klok La Crosse Technology
19 November 2024
19 November 2024
19 November 2024
15 November 2024
15 November 2024
15 November 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
Handleiding Klok
- Klok Braun
- Klok IKEA
- Klok Casio
- Klok Fysic
- Klok Xiron
- Klok Accusplit
- Klok Ade
- Klok Alecto
- Klok Amplicom
- Klok Ascot
- Klok Audiovox
- Klok Auriol
- Klok Balance
- Klok Balance Time
- Klok BBrain
- Klok Dexford
- Klok Digi-tech
- Klok Ecom
- Klok Elro
- Klok Eurochron
- Klok Fisher Price
- Klok Geemarc
- Klok Gingko
- Klok Gira
- Klok Global Tronics
- Klok GlobalTronics
- Klok Glunz
- Klok Hager
- Klok Hama
- Klok Hermle
- Klok IHome
- Klok Irox
- Klok Karlsson
- Klok Kogan
- Klok Konig
- Klok Krontaler
- Klok La Crosse
- Klok Lenovo
- Klok Lexon
- Klok Livoo
- Klok Lorus
- Klok Lydion
- Klok Marquant
- Klok Mebus
- Klok Mondaine
- Klok Muse
- Klok Nedis
- Klok Perel
- Klok Profile
- Klok Ranex
- Klok RCA
- Klok Salter
- Klok Sempre
- Klok Taylor
- Klok Techno Line
- Klok Technoline
- Klok TFA
- Klok Tronic
- Klok United Office
- Klok Velleman
- Klok Ventus
- Klok Vitek
- Klok Weinberger
- Klok Jacob Jensen
- Klok Jung
- Klok Oregon Scientific
- Klok McIntosh
- Klok Camry
- Klok ECG
- Klok Cresta
- Klok Citizen
- Klok Trevi
- Klok Zuiver
- Klok Chacon
- Klok Valcom
- Klok Dormakaba
- Klok AcuRite
- Klok ART
- Klok AV:link
- Klok Elation
- Klok ASA
- Klok TFA Dostmann
- Klok Antelope Audio
- Klok Equity
- Klok DB Technologies
- Klok Focus Electrics
- Klok Pyramid
- Klok CyberData Systems
- Klok Electronics International
- Klok Antelope
- Klok Bearware
Nieuwste handleidingen voor Klok
20 November 2024
19 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024