La Crosse Technology 404-1220 Handleiding
La Crosse Technology
Klok
404-1220
Lees hieronder de 📖 handleiding in het Nederlandse voor La Crosse Technology 404-1220 (5 pagina's) in de categorie Klok. Deze handleiding was nuttig voor 16 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/5
La Crosse Technology, Ltd Page 1
404- 1220 FAQ S
The links below will work in most PDF viewers and link to the topic area by clicking the link.
We recommend Adobe Reader version 10 or greater available at:
http://get.adobe.com/reader
CONT ENTS
404-1220 FAQS ................................................................................................................... 1
Batteries ............................................................................................................................. 2
Atomic Clock Factory Restart ...................................................................................... 2
Supported Time Zones 2 ..................................................................................................
Time is Incorrect ............................................................................................................. 2
Clock is incorrect by Hours but minutes are correct .......................................... 3
Daylight Saving Time ..................................................................................................... 3
Manually Set Time ........................................................................................................... 3
Auto Correction ................................................................................................................ 3
How long will the battery last? .................................................................................. 3
Can I shut off the WWVB signal? .............................................................................. 3
Is there a booster antenna to receive the WWVB signal in a difficult
location? ............................................................................................................................. 3
Can I wire a control timing circuit to the La Crosse Technology® atomic
clock? ................................................................................................................................... 4
Why do the hands spin once or twice everyday? ................................................ 4
Hands spin non-stop ...................................................................................................... 4
Hands jumps or jerks around the dial ..................................................................... 4
Hands stuck at certain time ........................................................................................ 4
Hands are loose. .............................................................................................................. 4
Position the Clock ........................................................................................................... 4
La Crosse Technology, Ltd Page 2
Can this clock be used outdoors? .............................................................................. 4
The hands stop at 4:00, 8:00 or 12:00 and never move. .................................. 4
The battery was removed and installed again. the hands do not move. .... 5
BATTERIES
Explanation: Many problems are resolved with fresh batteries of the appropriate voltage.
Many items sent in under warranty work when tested with fresh batteries. Batteries
manufactured this year will have an expiration date 10 years (or more) in the future.
Battery technology has improved and batteries will maintain voltage longer in storage.
However, the environment the batteries reside in for the 10 years can deplete the power.
We suggest a name-brand Alkaline battery .
A minimum voltage of 1.48V is necessary for proper performance.
Use a battery dated at least six years in advance of the current year. Batteries dated
earlier than six years from now may still work, but may be unstable in performance.
Good name-brand batteries make less noise, which reduces the chance of RF (radio
frequency) interference from the battery compartment.
ATOMIC CLOCK FACTORY RESTART
Explanation: The factory restart returns the atomic clock - -the-to an “out of box” state and
often resolves an issue.
Factory Restart:
1. Remove the battery from the clock for 15 minutes.
2. Press the Q-Set button at least 20 times to clear all memory.
3. After 15 minutes, insert fresh Alkaline battery into the clock.
4. The hands will spin to 12:00, 4:00 or 8:00 and wait for the WWVB time signal.
SUPPORTED TIME ZONES
This atomic clock offers four time zones: Pacific, Mountain, Central and Eastern.
La Crosse Technology® does not make an analog clock with more than four time zones.
The atomic clock works North America. in
Outside of North America, the atomic clock will not receive a WWVB signal, but will keep
time like a quartz clock if manually set.
TIME IS INCORRECT
Indicative of non-receipt of WWVB signal
Electrical storms between you and Colorado can interfere with the WWVB signal
Replace battery and perform restart procedure. Allow up to 5 days to receive a signal.
Reposition the atomic clock with the front or back facing Colorado.
Try a different location, ideally near a window. The clock should be at least six feet from
computers, TVs, air conditioners, other atomic clocks and other electrical appliances that
cause interference.
Large buildings, metal roofed buildings and buildings or rooms full of electrical and/or
radio equipment make it difficult to receive the WWVB time signal.
Locate the bronze colored pins in the upper left region of the movement on the back of
the clock. Short across the pins briefly with a screwdriver or similar metal object and
allow the hands to spin. The hands will stop all pointing at 12 when properly aligned.
La Crosse Technology, Ltd Page 3
Allow the clock to receive a signal and set itself. Then select the correct Time Zone for
your area.
CLOCK IS I NCOR RE CT B HOURS BUT MI NUTES AR E CO RR ECT Y
This is a Time Zone issue. Hold your Time Zone button for 5 seconds. The clock should
correct itself.
Check that DST is on. Press and release the small, unmarked gray button between the
ET and CT button one time.
DAYLI GHT SAVI NG TIME
Dependent on your location, position of the clock in your home, and atmospheric
interference, it may take up to 5 nights for the change from Daylight Savings Time to
Standard Time and vice-versa to occur.
Press the DST indicator once. If the indicator is OFF the clock will not change. (Default is
ON).
Check for fresh . Without proper batteries, the antenna will have a harder batteries
time picking up the signal.
Position the atomic clock in a window (with the front or back) facing Ft. Collins, Colorado
and leave for up to five nights. If you do not have a window facing this direction,
position the clock near an outside wall and point the unit in this general direction.
MANU ALLY S E T TI ME
1. Press and hold the Q-Set button on the backside of the movement until the second hand
starts running.
2. Release the button quickly (less than 3 seconds) and press it again to set actual time.
3. Three seconds after releasing the Q-Set Button your clock will start working as a Quartz
Clock.
4. In Quartz Mode, your clock will try to receive each even hour. If a signal is received, it
will override the manual set time.
AUTO CORRE CTIO N
Between 3:00 and 4:05pm daily, the clock automatically checks its hands
position. If hands position is not equal to internal time, the hands are driven
(quick run) to the correct time again.
You will see the hands spin completely around during this correction.
This is normal behavior.
HOW LONG W ILL THE BAT TERY LAST?
A good AA Alkaline battery will last over 12 months.
CAN I SHUT OFF THE W WVB S IG NAL ?
No. If you manually set the time, when the clock receives a WWVB signal, that signal
will override the manual set.
IS THE RE A BOO STER ANT ENN A TO RE CEIV E TH E W WVB SIGN AL IN A
DIFF ICULT LOCAT ION?
No, the clock cannot work with a booster antenna.
Opening the clock or movement voids the warranty.
Product specificaties
Merk: | La Crosse Technology |
Categorie: | Klok |
Model: | 404-1220 |
Kleur van het product: | Black, White |
Soort: | Atoomwandklok |
Vormfactor: | Cirkel |
Diameter: | 508 mm |
Accu/Batterij voltage: | 1.5 V |
Ondersteund aantal accu's/batterijen: | 1 |
Wekker: | Nee |
Thermometer: | Nee |
Hygrometer: | Nee |
Batterijen inbegrepen: | Nee |
Type batterij: | C |
Heb je hulp nodig?
Als je hulp nodig hebt met La Crosse Technology 404-1220 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Klok La Crosse Technology
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
5 December 2024
19 November 2024
19 November 2024
19 November 2024
15 November 2024
Handleiding Klok
- Klok Braun
- Klok IKEA
- Klok Casio
- Klok Fysic
- Klok Xiron
- Klok Accusplit
- Klok Ade
- Klok Alecto
- Klok Amplicom
- Klok Ascot
- Klok Audiovox
- Klok Auriol
- Klok Balance
- Klok Balance Time
- Klok BBrain
- Klok Dexford
- Klok Digi-tech
- Klok Ecom
- Klok Elro
- Klok Eurochron
- Klok Fisher Price
- Klok Geemarc
- Klok Gingko
- Klok Gira
- Klok Global Tronics
- Klok GlobalTronics
- Klok Glunz
- Klok Hager
- Klok Hama
- Klok Hermle
- Klok IHome
- Klok Irox
- Klok Karlsson
- Klok Kogan
- Klok Konig
- Klok Krontaler
- Klok La Crosse
- Klok Lenovo
- Klok Lexon
- Klok Livoo
- Klok Lorus
- Klok Lydion
- Klok Marquant
- Klok Mebus
- Klok Mondaine
- Klok Muse
- Klok Nedis
- Klok Perel
- Klok Profile
- Klok Ranex
- Klok RCA
- Klok Salter
- Klok Sempre
- Klok Taylor
- Klok Techno Line
- Klok Technoline
- Klok TFA
- Klok Tronic
- Klok United Office
- Klok Velleman
- Klok Ventus
- Klok Vitek
- Klok Weinberger
- Klok Jacob Jensen
- Klok Jung
- Klok Oregon Scientific
- Klok McIntosh
- Klok Camry
- Klok ECG
- Klok EMOS
- Klok Cresta
- Klok Citizen
- Klok Trevi
- Klok Zuiver
- Klok Chacon
- Klok Valcom
- Klok Dormakaba
- Klok AcuRite
- Klok ART
- Klok AV:link
- Klok Elation
- Klok ASA
- Klok TFA Dostmann
- Klok Antelope Audio
- Klok Equity
- Klok DB Technologies
- Klok Focus Electrics
- Klok Pyramid
- Klok CyberData Systems
- Klok Electronics International
- Klok Antelope
- Klok Bearware
Nieuwste handleidingen voor Klok
14 December 2024
14 December 2024
14 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024
7 December 2024