GC-61 GSM communicator 1 / 1 MHZ51105
The GC-61 GSM communicator
Installation manual
The GC-61 communicator is designed for communication with an
alarm receiving centre via a GSM network. The communicator receives
data from a control panel via a simulated telephone line. Report codes
are transmitted from a control panel to the GC-61 in Contact ID format.
A SIM card determines the GSM network used. This manual is valid for
version HZ61008.
The GSM module, when installed in the alarm control panel, enables:
• Data transfer to one or two Alarm Receiving Centres (ARC)
• Remote control and programming of the communicator via SMS
instruction messages from a mobile phone or from Jablotron’s SMS
website
• Programming of the communicator via Jablotron’s website
www.GSMlink.cz
• Phone calls using a telephone set attached to the communicator
(via the GSM network)
• An SMS terminal can be used for the easy and convenient
receiving and sending of SMS messages
1. Installation
The communicator can be installed into an alarm control panel or into
a metallic box with a TAMPER switch.
a) Disconnect the control panel’s power supply (both AC and
backup battery). If the control panel has been previously used
before this installation, enter programming mode before
disconnecting the power supply.
b) We recommend you to disable the SIM card PIN code protection
before you insert it into the dialler. Use a mobile phone to perform
this task (if you have a NOKIA phone, select: Menu, Settings,
Security settings, PIN code request, Off). If you insist on using a
PIN, enter PIN 1234.
c) Open the SIM card holder (by sliding it in the direction shown in
the figure 1 below and insert the SIM card into the holder and
close it by sliding it back.
d) Attach the communicator into the control panel case or metallic box
e) Connect the GSM antenna (never switch the power supply on
without a proper antenna)
f) Connect a telephone set to the PHONE connector (or to the
PHONE terminals) together with the SMS terminal if desired. Only
one telephone set can be attached to the dialler. The PHONE
output of the dialler should never be connected to any other
telephone network.
GC-61
connector
K1
GSM network
failure monitoring
telephone dialer
+12V
GND
INP
GSM ANTENNA
Figure. 1
g) The AUX output is switched on if the GSM network is not available
for 15 minutes. AUX can be used as an alarm terminal. (normally
open dry contact, max. 100mA / 60V) – see the figure 1
h) It is possible to connect an external device (tamper, alarm output
etc.) to the INP input. When activated (by disconnection from
GND), then an activation event will be sent to the ARC (in CID
protocol “1”) and a deactivation event will be sent after
reconnecting INP to the GND.
i) Connect the control panel’s power supply. The LED will start
flashing once every 2 seconds when it has successfully registered
to the GSM network (within 1 minute).
If the LED starts flashing quickly, the module was not able to connect
to the GSM network. In this case, switch off the control panel power.
Remove the SIM card and insert it into a mobile phone to confirm
whether it is possible to connect to the network at this location. You
can also select a desired network manually if this option is available.
Ensure that the SIM card does not request a PIN code (or the PIN
code is set to 1234) Once the SIM card works in the mobile phone,
insert it back into the GSM dialler and repeat step i). If the GSM signal
is weak in this area, change the location of the GSM antenna before
you try to re-establish the connection. The level of GSM signal can be
checked by the SMS command “DINFO”.
j) After connection to the GSM network you can call directly from the
attached telephone.
k) Set all the parameters for Alarm Receiving Centre communication.
l) Programming of the GSM dialler is possible by entering
programming sequences via a mobile phone or an attached SMS
terminal. The most convenient programming method however is via
the www.GSMlink.cz website.
2. Alarm Receiving Centre communication
setting:
The dialler can report events to two different Alarm Receiving
Centres (ARCs). Each ARC has its own setting sequences that differ in
parameter p (p=1 for ARC1 and p=2 for ARC2). Primary and backup
telephone or IP numbers can be set for each ARC. The dialler uses
Ademco Contact ID format and it is also equipped for the future use of
GPRS data transfers. The product is ready to report events to an ARC
based on either landline or GSM data transfer.
The GC-61 re-sends original report codes – the content is not modified
except the Account ID. The communicator forwards original CID
protocol report codes with separator constants 18 and 98 to the ARC
(the constants are converted to 18 during forwarding). Otherwise, their
contents are not altered except for the installation number, which is set
according to communicator settings. The time of a sent event is
generated by the GC-61. The system time is set when the first SMS is
received by GC-61.
Every SMS command must begin with a service access code.
Several setting sequences can be sent within a single SMS.
Sequences must be separated by a comma or space.
2.1. Digital dialler setting
The digital dialler must be set to:
format : Contact ID
ARC telephone number (DTMF): 002
2.2. GPRS setting
GPRS data communication can be used for transmitting events to an
ARC or for connection to the web page www.gsmlink.cz (see section
3). GPRS must be activated on the SIM card. It is also necessary to
set the name and APN in the communicator (for detailed information
ask your GSM provider).
GPRS xxx,yyy,zzz,
where: xxx is the APN
yyy is a the user name (when not used, insert a space)
zzz is a password (when not used, insert a space)
Example: If the name and password are not required and the APN is
“internet”, then the sequence is: 0000 GPRS internet, , ,
2.3. Setting the service remote access code
PG0 xxxxxxxx
Where: xxxxxxxx is a numerical code of 1 to 8 figures
Default setting: 0000 (4 zeros)
2.4. Entering ARC phone numbers (IP addresses)
Primary and back up telephone numbers can be entered for each
ARC:
Primary number: PG1p xx....x
Back up number: PG2p xx....x
where:
GC-61 GSM communicator 2 / 2 MHZ51105
p 1 = ARC1, 2 = ARC2
xxx...x is a telephone number (max. 20 digits) or an IP
address plus port beginning with a #. The IP plus port
must be specified by exactly 4x3 + 5 = 17 digits using
zeros for left-hand bit stuffing, if necessary.
Examples:
(a) 123456789 can be entered as the ARC2 primary number by
entering: 0000 PG12 123456789.
(b) IP address 192.168.1.123 together with port 8080 are set as the
ARC1 primary number by entering PG11#192 168 001 123 08080.
Default setting: No phone number or IP address is set.
2.5. Account ID setting
An ARC uses this ID number for alarm system identification:
PG3p zzzz
where: p 1=ARC1, 2=ARC2
zzzz is the account ID number (z = numbers from 0 to 9 or
A=F1, B=F2, C=F3, D=F4, E=F5 a F=F6,
hexadecimal)
Default setting: ID is 0000 for both ARCs
Note: When an Account ID for ARC1 and ARC2 are not set, it will be
set according to the first received event from a control panel.
2.6. Selecting the ID number
It is possible to select the ID number of the GC-61 or the ID number of
the attached landline communicator for transmission to an ARC.
PG94 x
where:
x=0 The ID number of the GC-61 is used for alarm system
identification.
x=1 The ID number of the attached landline communicator
is used for alarm system identification.
Default setting: x=0
Notes:
The setting can only be done by SMS.
The events from the GC-61 (e.g. triggering its own input), are
transferred with an ID number according to the PG3p zzzz settings.
2.7. Format setting
This sequence is used to select the communication format:
PG4p x
where: p 1=ARC1, 2=ARC2
x is the protocol type – see table
Default setting: Contact ID for both ARC’s
Protocol Type x
Contact ID DTMF 0
Jablotron SMS SMS type 1
Jablotron GPRS GPRS type 2
2.8. Disabling ARC communication
If you need to temporarily disable all ARC reporting, you can do this,
while retaining your settings:
PG5p 1 all reports to ARC p enabled
PG5p 0 all reports to ARC p disabled
where: p 1=ARC1, 2=ARC2
Default setting: all ARC reports disabled.
2.9. ARC 2 as a back-up for ARC1
ARC 2 can serve as an optional back-up for ARC data transfer if
ARC1data transfer fails. When the first event is transferred to the back-
up monitoring station (ARC2) a “tel. line #1 communication fault“ event
will be reported.
PG62 0 ARC1 and ARC2 are two independent stations
PG62 1 ARC 2 works as a transfer back-up
When 081 is selected, the ARC 2 settings are used only if ARC 1
transfer fails .
Default setting: two independent ARC’s.
2.10. ARC re-dialling interval setting
If the dialler is activated it attempts to make a connection (alternating
between the primary and the back-up telephone number). If it is not
possible to make a connection, a dialling pause is initiated. After this
interval the dialler will re-attempt to make a connection. The interval
can be set in the following way:
PG7p t
where: p 1 = ARC1, 2 = ARC2
t is the pause duration x 5 minutes (i.e.1 = 5 minutes,
2 = 10 min,..., 9 = 45 minutes etc)
Default setting: 5 minutes for both ARCs
2.11. Interval of periodic test
Periodic tests are sent by the GC-61. These events do not depend
on a connected control panel. The following sequence sets the time
interval between periodic test messages:
PG8p hh:mm
where: p 1 = ARC1, 2 = ARC2
hh is hours
mm is minutes
Default setting: the periodic test is not sent – 00:00 is set
2.12. INP input CID code setting
When the INP input is used for transmission to an ARC, it is
necessary to set CID code for the required event. Enter the following
sequence:
PG91 xxxyyzzz
where: xxx is the event (e.g. alarm – 130, tamper – 137,
arm/disarm – 401 etc.)
yy is the number of the subsystem
zzz is the number of event source
Example: if you enter PG91 13001123, then on activation of the INP
input, the report –“ alarm to subsystem 01, event source 123” will be
sent to the ARC.
Default setting: no report is transferred.
2.13. Phone number prefix setting.
In some countries it is necessary to use “00” instead of the “+”
character as a prefix at the beginning of a phone number to be able to
send SMS message. If required, enter this sequence:
PG92 xx
Where: xx is the prefix which will be used instead of “+”
Enter PG92 to reset to the default setting.
Default setting: “+”.
2.14. Reset to the default setting
When the SMS “reset” is sent to the GC-61, the factory default
setting will be restored. A hardware reset can also be performed as
follows:
Switch off the power supply, connect the two middle pins of the K1
connector and restore the power supply. The hardware reset is
indicated by fast LED flashing.
2.15. Reset – GSM module
When the command gsm is sent to the GSM module it will
disconnect from and then reconnect to the GSM network. This function
is useful when it is necessary to switch the mobile device off and on
(e.g. when the SIM card has been unblocked by the mobile operator).
2.16. Appliance remote control by SMS (AUXON,
AUXOFF)
These commands can be used to control the AUX output (e.g. switch
a telephone line to the control panel). The switching event is sent to an
ARC. The AUX is also switched on if a GSM network is not available
for 15 minutes.
To switch on the AUX output, send the SMS text: AUXON
To switch off the AUX output, send the SMS text: AUXOFF
GC-61 GSM communicator 3 / 3 MHZ51105
3. Web server remote access
3.1. Settings via the GSMLink web server
The GSMLink server allows a user to read and change the control
panel and dialler configurations. Data transfer is done by sending an
SMS or by GRPS.
The number of SMSes sent is optimised to minimize costs. GPRS
data transfer can also be used, but must be activated on the SIM card.
3.2. GSMLink Website Registration
The www.gsmlink.cz website: To register your system use the
registration code printed on the warranty certificate (the code has the
form xxxx-xxxxx-xxxx and it is unique to each system).
You can ask for the registration code by using the DINFO SMS
command. After sending the SMS from your mobile phone: (remote
access code) DINFO “0000 DINFO”, you will receive an SMS reply
with the registration code and the level of the GSM signal.
4. User features of the GSM communicator
The GC-61 can be also used as a GSM network gateway. It cannot
be used as an ARC communicator in this mode. The 10k resistor must
be removed from PHONE terminals.
4.1. Phone calls from the attached telephone set
After the GSM module is connected to the GSM network, an attached
phone can be used to make calls. If you pick up the phone, you will
hear a dial tone. Simply dial the number you want to call (as if you are
dialling from a normal fixed line phone). You can also dial the GSM
communicator’s phone number from another phone, and its attached
phone will ring as a normal land line phone would.
Note: some telephone sets are sensitive to the GSM radio signal. For
this reason you may hear a buzzing noise in the telephone receiver
when calling. If the noise is disturbing, change the location of the
phone set (try to keep it as far as possible from the GSM dialler
antenna). Usually it is possible to find a suitable location for the phone
with a minimum level of interference.
4.2. Function of the attached SMS terminal
The communicator has a telephone connector, which can be used for
connection to an MT-77 Piccolo terminal. A detailed description is in
the separate manual enclosed with the Piccolo terminal.
Setting:
• For sending SMSes to mobile phones it is necessary to set the
SMS centre 1 to “1111”.
• By sending SMSes to telephone number “001”, the control panel
can be controlled using SMS instructions
Notes:
When displaying the caller’s telephone number (CLIP), the telephone
number is shown in international format (e.g.00420212345678).
5. Additional information
5.1. Procedure for report data transfer:
If the communicator is activated to send reports it will:
• Send information to ARC1 (to the primary number, if it fails the
backup number will be used); this process is repeated twice.
• Send information to ARC2
• If communication with the ARC is unsuccessful, the communicator
will try to send it again after a pause set by sequence PG7. The
GC-61 has a memory for 128 events.
5.2. LED indicator
• If the LED is flashing, the dialler is not registered to the GSM
network
• If the LED is flashing in short bursts:
Once in 2 seconds =normal status
Twice in 2 seconds = the balance resistor has not been detected
• If the LED is on – communication with a GSM network is occurring.
5.3. ARC communication
If the GC-61 is being used for the first time or any parameters have
been changed then the first successful communication with an ARC
will result in a short ring on the connected telephone set (if there is
one).
When the GC-61 receives 10 report codes from the control panel then
the GC-61 will suspend communication with the control panel and the
received report codes will be sent to an ARC. The command MO can be
used to read the current status of the GSM dialler. The dialler will reply
with an SMS showing the level of GSM signal, GPRS status, and
whether data transfer to ARCs is successful or not.
Example: After sending the MO instruction, the communicator will reply
with the SMS: Alarm system reports: Control panel status:
GSM:7,GPRS OK,MS1 NOT,MS2 OK
5.4. Setting SMS
When an SMS command has been processed correctly, the GC-61
sends back a confirmation SMS e.g.:
„ Settings stored: PG11 123456789“
Or in the case of error:
„ Wrong settings“
5.5. Telephone line supervision
When a 10 kî‚ź resistor is attached to the PHONE terminals, the
telephone line is balanced. When the balancing resistor is connected
to the control panel, the connection between the GC-61 and the control
panel is supervised. If the telephone line is disconnected for 30 s, the
GC-61 will send a report to an ARC.
6. Specification
Power supply 12V DC
Stand-by consumption 50 mA
Maximum consumption (during communication) 1 A
Operating bands E-GSM / GPRS 900/1800MHz
Output power 2 W for GSM900, 1 W for GSM1800
AUX terminals dry contact, max. 60 V / 100 mA
Environmental classification ( –10 to 40°C) II
EMC ETSI EN 301489-1, ETSI EN 301489-7
EN 55022, EN 5030-4
Emissions ETSI EN 301419-1 and EN 301511
Caller identification (CLIP) ETSI EN 300 089 V3.1.1(2000-12)
Jablotron Ltd. hereby declares that the GC-61 is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Dispose of batteries safely depending on battery type
and local regulations. Although this product does not contain
any harmful materials we suggest you return the product to
the dealer or directly to the manufacturer after use.
Product specificaties
Merk: | Jablotron |
Categorie: | Beveiliging |
Model: | GC-61 |
Heb je hulp nodig?
Als je hulp nodig hebt met Jablotron GC-61 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Beveiliging Jablotron
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
20 Maart 2023
Handleiding Beveiliging
- Beveiliging Bosch
- Beveiliging Panasonic
- Beveiliging Bticino
- Beveiliging Fysic
- Beveiliging Grundig
- Beveiliging Honeywell
- Beveiliging Medion
- Beveiliging Siemens
- Beveiliging Abus
- Beveiliging AceSee
- Beveiliging Airbolt
- Beveiliging Ajax
- Beveiliging Alecto
- Beveiliging Alhua - Dahua
- Beveiliging Alphatronics
- Beveiliging AngelEye
- Beveiliging Aritech
- Beveiliging Audiovox
- Beveiliging AVTech - Velleman
- Beveiliging Axa
- Beveiliging Axis
- Beveiliging Basetech
- Beveiliging Batavia
- Beveiliging Bavaria
- Beveiliging Bellman
- Beveiliging Bitron Video
- Beveiliging Blaupunkt
- Beveiliging BML
- Beveiliging Bolyguard
- Beveiliging Brennenstuhl
- Beveiliging BRK
- Beveiliging BRK DICON
- Beveiliging Dahua
- Beveiliging Dedicated Micros
- Beveiliging Dericam
- Beveiliging Devolo
- Beveiliging Directed Electronics
- Beveiliging Dnt
- Beveiliging Doro
- Beveiliging Dymond
- Beveiliging Easy Home
- Beveiliging Easymaxx
- Beveiliging Eden
- Beveiliging Edimax
- Beveiliging Ednet
- Beveiliging Electronics Line
- Beveiliging Elkron
- Beveiliging Elro
- Beveiliging Elro-Flamingo
- Beveiliging Eminent
- Beveiliging Entrya
- Beveiliging Epine
- Beveiliging Eufy
- Beveiliging Ezviz
- Beveiliging FBII
- Beveiliging Fenton
- Beveiliging First Alert
- Beveiliging Flamingo FA15RF
- Beveiliging FlinQ
- Beveiliging Foscam
- Beveiliging Fracarro
- Beveiliging Friedland
- Beveiliging Galaxy
- Beveiliging GE Security
- Beveiliging Geemarc
- Beveiliging Gira
- Beveiliging Goliath
- Beveiliging Golmar
- Beveiliging Goobay
- Beveiliging Grandstream
- Beveiliging Grothe
- Beveiliging Guardall
- Beveiliging Hagenuk
- Beveiliging Heidemann
- Beveiliging Hikvision
- Beveiliging Home Protector
- Beveiliging Home8
- Beveiliging HomeWizard
- Beveiliging HUMANTECHNIK
- Beveiliging I-onik
- Beveiliging I-Tel
- Beveiliging Iget
- Beveiliging Iiquu
- Beveiliging Indexa
- Beveiliging Inner Range
- Beveiliging Interlogix
- Beveiliging Kocom
- Beveiliging Kompernass
- Beveiliging Kopp
- Beveiliging Ksenia
- Beveiliging Lamax
- Beveiliging LevelOne
- Beveiliging Logicom
- Beveiliging Maginon
- Beveiliging Marmitek
- Beveiliging Marquant
- Beveiliging ME
- Beveiliging Microtech
- Beveiliging Mikros
- Beveiliging Monacor
- Beveiliging Mr Safe
- Beveiliging Muller
- Beveiliging Myfox
- Beveiliging Nedis
- Beveiliging Nemef
- Beveiliging Nest
- Beveiliging Netatmo
- Beveiliging NetBotz
- Beveiliging Netgear
- Beveiliging NetworX
- Beveiliging Niko
- Beveiliging Nor-tec
- Beveiliging Notifier
- Beveiliging Paradox
- Beveiliging Perel
- Beveiliging PIR Alarm
- Beveiliging Plustek
- Beveiliging Powerfix
- Beveiliging Powermax
- Beveiliging Prestigio
- Beveiliging Profile
- Beveiliging PROmax
- Beveiliging Protector
- Beveiliging Provision ISR
- Beveiliging QuattSecure
- Beveiliging Ranex
- Beveiliging RISCO Group
- Beveiliging Satel
- Beveiliging SecuFirst
- Beveiliging Secure Pro
- Beveiliging Securitas
- Beveiliging Selvag
- Beveiliging Skytronic
- Beveiliging Smanos
- Beveiliging Smartalarm
- Beveiliging SmartHome
- Beveiliging Smartwares
- Beveiliging Somfy
- Beveiliging Sonic Alert
- Beveiliging Steinel
- Beveiliging Stobo
- Beveiliging Storage Options
- Beveiliging Storex
- Beveiliging Switel
- Beveiliging Sygonix
- Beveiliging Technaxx
- Beveiliging Tegui
- Beveiliging Tevion
- Beveiliging Theben
- Beveiliging Topcraft
- Beveiliging Trebs
- Beveiliging Trendnet
- Beveiliging Trust
- Beveiliging Unitec
- Beveiliging Unitron
- Beveiliging Urmet
- Beveiliging V-Tac
- Beveiliging Velbus
- Beveiliging Velleman
- Beveiliging Visonic
- Beveiliging Voxx
- Beveiliging Waeco
- Beveiliging Wanscam
- Beveiliging Woonveilig
- Beveiliging Xavax
- Beveiliging Xena
- Beveiliging Y-cam
- Beveiliging Yale
- Beveiliging Zmodo
- Beveiliging Jacob Jensen
- Beveiliging Jung
- Beveiliging Jupiter Pro
- Beveiliging Juwel
- Beveiliging One2track
- Beveiliging Oplink
- Beveiliging Optex
- Beveiliging Orbis
- Beveiliging Overmax
- Beveiliging Fito
- Beveiliging One Concept
Nieuwste handleidingen voor Beveiliging
6 Maart 2024
4 Februari 2024
16 Oktober 2023
16 Oktober 2023
16 Oktober 2023
16 Oktober 2023
16 Oktober 2023
16 Oktober 2023
16 Oktober 2023
16 Oktober 2023