ShatterPro 3 Glassbreak Detector Installation Instructions
Introduction
This is the ShatterPro 3 Glassbreak Detector Installation
Instructions. The ShatterPro 3 is an acoustic glassbreak
detector designed to detect breaking glass from framed
windows in the perimeter of a building. The detector is
mounted in the building interior and uses a power supply from
a 12 VDC control panel. The detector is available in either a
low-profile round housing or a rectangular housing that
connects easily to a single-gang box (Figure 1 below).
Figure 1: ShatterPro 3 housings
The detector provides the following features:
Range up to 25 ft. (7.6 m)
Internal spring clip allows optimized room size coverage.
Alarm memory
After an alarm and until power is cycled, the alarm memory can
be checked with the hand-clap test.
LED indicator
Red LED provides detector test and status indication.
Tamper resistant
The detector has a screw that secures the cover to the base to
prevent tampering.
Hand-clap test
In addition to a test mode, you can test the detector by
clapping your hands.
Optional tamper switch
Sends a signal to the control panel when the cover is removed
from the base.
You will need the following tools and parts to install the
detector:
• ShatterPro 3 detector including cover screw
• Screws and wall anchors
• Flat-blade screwdriver
• Phillips screwdriver
• UTC Fire & Security 5709C hand-held tester
Mounting location
You can mount the detector on ceilings or on the walls
opposite or adjacent to the window to be protected (Figure 2
below).
Figure 2: Mounting locations
Ceiling
mount
Wall
mount
25' (7.6 m)
max.
25' (7.6 m)
max.
Use the following guidelines to determine the best mounting
location:
• Mount the detector at least 3 ft. (1 m) from the windows
being protected.
• Windows must be at least 12 x 24 in. (30.5 x 61 cm).
• Avoid locations where insulating, sound deadening, or
lined drapes or closed wooden shutters are used.
• Mount 12 in. (30.5 cm) away from wall corners.
• Locate in a suitable environment: temperature between 32
and 122°F (0 and 50°C); and humidity between 10 and
90% noncondensing.
P/N 1030856 • REV E • 21APR11 1
• Mount the detector on a stable surface up to 25 ft. (7.6 m)
from the farthest point on the glass surface.
• Avoid locations that expose the detector to possible false
alarm sources such as:
• Glass airlocks and vestibule areas
• Kitchens
• Residential car garages
• Small utility rooms
• Stairwells
• Bathrooms
• Small acoustically live rooms
• Air vents
Multiple window coverage
The detector has a 360 degree coverage pattern that can be
used to cover several windows in a single room. To use this
coverage pattern, do the following:
1. Draw an imaginary line from the center of each window to
be covered in toward the center of the room.
2. Mount the detector on the ceiling as close as possible to
where the lines intersect (Figure 3 below).
Figure 3: Multiple window coverage
Ceiling
mount
Detector
60 max.
60 max.
Do not mount the detector at more than a 60 degree angle
from the center of any window to be protected.
Installation
All wiring must conform to the National Electric Code (NEC)
and/or local codes having jurisdiction.
Caution: If you are unsure about location, connect a 9V
battery to the detector and test it before permanently mounting
the detector.
To install the detector, do the following:
1. Run the security system wiring to the detector location.
2. Remove the front cover of the detector as follows:
Round housing
Press the release tab on the lip of the base, twist the cover
counter clockwise, and lift the cover off (Figure 4 below).
Figure 4: Round housing parts
Microphone
LED
Release tab
Rectangle housing
Insert a flat-blade screwdriver into the slot on the bottom of the
cover and gently pry up to unlock the cover. Grasp the bottom
of the cover and lift up until the cover plate is in the open
position (Figure 5 below).
Figure 5: Detector knockout locations
J3 Spring clip
Knockouts
J3 Spring clip
Slot
Knockouts
3. Set the range with J3 spring clip on the circuit board. See
“Range settings” on page 3.
4. Remove the appropriate wiring and mounting knockout
holes from the base. See Figure 5 above for rectangle
housings and round housings.
5. Pull the wires through the knockout holes and use two
screws to attach the base to the surface. Use wall anchors
if necessary.
6. Strip 3/8 in. of insulation from each wire.
7. Connect the system wires to the appropriate screw
terminals on the base and tighten the screws (Figure 6 on
page 3).
2 ShatterPro 3 Glassbreak Detector Installation Instructions
Figure 6: Wiring diagram
GND +12V N.C. COM N.O. T AMP TAMP
GND +12V N.C. COM
J3 Spring clip
J3 Spring clip
Tamper Switch
Models:
5812NT
R5812NT
Models:
5815NT
R5815NT
8. Replace the cover as follows:
Rectangle housing
Press the cover back down over the detector until the
cover snaps firmly into place.
Round housing
Line up the tabs on the base with the corresponding tabs
on the cover, press together and turn clockwise until the
cover snaps firmly into place (Figure 7 below).
Figure 7: Attaching the round cover
9. Apply power. The red LED should flash once.
10. Test the detector. See “Testing” below.
Range settings
The detector has a spring clip (J3) to set the room size
( Figure 6 above). Use Table 1 below to determine what setting
to use for your application
Table 1: Setting the range
Setting Description
Open Default. Use for rooms 100 square ft. and larger, Range
5 to 25 ft (1.5 to 7.5 m).
Closed Use for rooms smaller than 100 square ft. Range 3 to 10
ft. (0.9 to 3 m).
Testing
To verify detector range and operation, you need the UTC Fire
& Security 5709C handheld tester.
To test the detector, do the following:
1. Set the tester to the appropriate glass-type setting. Use
the tempered setting if you are unsure about the glass
type.
2. To put the detector in test mode, hold the tester so that the
speaker is within 1 in. (25 mm) of the detector microphone
( Figure 8 below) and activate the tester. When the
detector is in test mode the LED on the detector lights
steady for 4 seconds and then flashes for 60 seconds. The
relay opens for 4 seconds, then returns to standby. Time
resets after each valid test.
Figure 8: Using the tester
• le Sing
• Co nt
in uo
usPla
te •
Te
m
p eer
d •
Lam in a dte •
Bat te ry LED
Ba
t t
ery is O iK f LED
st a ys on
du
r
in g
t e
st
5
709
C
Shatt e r
S ieer s T
es
t e r
U
se f or
t e stin g :
Shatt erPr
o
Sha rtt e
box
Sha
t
t e rbox II
Sha e rt t Swi t c
h
SEN
TRO
L
When the detector is in test mode,
the LED lights steady for 4 seconds,
then flashes for 60 seconds. Time
resets after each valid test.
1” (2.54 cm)
Hold the tester so that the speaker is
within 1” of the detector microphone.
3. Hold the tester near the surface of the glass to be
protected and aim the speaker at the detector. Be sure the
tester is at the point on the glass farthest from the
detector. If closed drapes or curtains are present, hold the
tester behind them (Figure 9 below).
Figure 9: Testing behind curtains
4. Press the test button on the tester. The LED on the
detector should stay on for 4 seconds to indicate the glass
ShatterPro 3 Glassbreak Detector Installation Instructions 3
Product specificaties
Merk: | Interlogix |
Categorie: | Deur-/raamsensor |
Model: | ShatterPro 3 |
Kleur van het product: | Wit |
Breedte: | 102 mm |
Diepte: | 102 mm |
Hoogte: | 21 mm |
Gebruikershandleiding: | Ja |
Voeding, voltage ingang: | 16 V |
Aantal producten inbegrepen: | 1 stuk(s) |
Heb je hulp nodig?
Als je hulp nodig hebt met Interlogix ShatterPro 3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Deur-/raamsensor Interlogix
19 Maart 2023
16 Januari 2023
Handleiding Deur-/raamsensor
- Deur-/raamsensor Bosch
- Deur-/raamsensor Abus
- Deur-/raamsensor Axis
- Deur-/raamsensor Ezviz
- Deur-/raamsensor Hama
- Deur-/raamsensor Hikvision
- Deur-/raamsensor KlikaanKlikuit
- Deur-/raamsensor Konig
- Deur-/raamsensor Marmitek
- Deur-/raamsensor Nedis
- Deur-/raamsensor Satel
- Deur-/raamsensor Smartwares
- Deur-/raamsensor Somfy
- Deur-/raamsensor Vivanco
- Deur-/raamsensor X4-Tech
- Deur-/raamsensor Xavax
- Deur-/raamsensor Olympia
- Deur-/raamsensor Optex
- Deur-/raamsensor Caliber
- Deur-/raamsensor Schwaiger
- Deur-/raamsensor Steren
- Deur-/raamsensor EMOS
- Deur-/raamsensor Avidsen
- Deur-/raamsensor Techly
- Deur-/raamsensor DSC
- Deur-/raamsensor Nexa
- Deur-/raamsensor Fibaro
- Deur-/raamsensor Kidde
- Deur-/raamsensor Chamberlain
- Deur-/raamsensor Energenie
- Deur-/raamsensor Speed-Link
- Deur-/raamsensor Homematic IP
- Deur-/raamsensor ORNO
- Deur-/raamsensor Kanlux
- Deur-/raamsensor Inovonics
- Deur-/raamsensor Tellur
- Deur-/raamsensor Sonoff
- Deur-/raamsensor Gewiss
- Deur-/raamsensor Setti+
Nieuwste handleidingen voor Deur-/raamsensor
6 Oktober 2024
13 September 2024
12 September 2024
22 Augustus 2024
22 Augustus 2024
15 Juli 2024
15 Juli 2024
15 Juli 2024
9 Juli 2024
9 Juli 2024