HQ EL-PIR70 Handleiding


Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor HQ EL-PIR70 (66 pagina's) in de categorie Bewegingsdetector. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/66
EL-PIR70
Radar motion sensor
This sensor is an active motion detector. The integrated HF sensor emits high-
frequency electro-magnetic wave (5.8GHz) and receives their echo. The sensor
detects the change in echo from even the slightest movement in the lightโ€™s detection
zone. A microprocessor then triggers the โ€œswitch light ONโ€ command. Detection is
possible through doors, panes of glass or thin walls.
Detection zones for ceiling mounting
1) Minimum reach 1m dia.
2) Maximum reach 8m dia.
Detection zones for wall mounting
3) Minimum reach 1m dia.
4) Maximum reach 8m dia.
Important: persons or objects moving towards
the light are detected best!
Installation procedures
1. Take down the top cover by turning it anti-clockwise (see ๎„‹g.1), and then tighten off
the two screws ๎„‹xing middle cover (see ๎„‹g. 2);
2. Hold base against the wall and mark drill holes, paying attention to any existing
wiring in the wall;
3. Drill the holes, insert wall plugs (6mm dia);
4. Put the power wire and load wire through the base holes;
5. Screw the base into place (see ๎„‹g. 3);
6. Connect the mains power supply and the load wire to the connection terminal
according to connection-wire mark.
7. Close the middle cover (see ๎„‹g. 3) and adjust knob to setting;
8. Fit glass shade and turn it clockwise (see ๎„‹g. 3).
๎„‹g 1 ๎„‹g 2 ๎„‹g 3
1
Technical speci๎„‹cations
power supply: 220-240VAC
power frequency: 50/60Hz
Installation sit: indoors, wall/ceiling mounting
HF system: 5.8GHz CW radar, ISM band
transmission power: <10mW
rated load:1200W: 220-240VAC
detection angle: 360ยฐ, 160ยฐ
reach:1-8m (dia.), adjustable
time setting: 5sec to 15min
light control: 2~2000LUX
Connection illumination
connect N,L with power; connect N, Lโ€™ with load
Reach setting (sensitivity)
Reach is the term used to describe the diameter of
the more or less circular detection zone produced
on the ground after mounting the sensor at a height
of 2.5m, turn the reach control fully anticlockwise
to select minimum reach (approx.1 m dia), and fully
clockwise to select maximum reach (approx. 8m dia).
Time setting
The light can be set to stay ON for any period of time between approx. 5sec
(turn fully anticlockwise) and a maximum of 15min (turn fully clockwise).
Any movement detected before this time elapse will re-start the timer. It is
recommended to select the shortest time for adjusting the detection zone
and for performing the walk test.
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start
detecting movement again. The light will only switch on in response to movement
once this period has elapsed.
Light-control setting
The chosen light response threshold can be in๎„‹nitely from approx. 2-
2000lux. Turn it fully anti-clockwise to select dusk- to-dawn operation at
about 2 lux. Turn it fully clockwise to select daylight operation at about
2000lux. The knob must be turned fully clockwise when adjusting the
detection zone and performing the walk test in daylight.
2
1-8 dia
5sec~15min
2~2000LUX


Product specificaties

Merk: HQ
Categorie: Bewegingsdetector
Model: EL-PIR70
Kleur van het product: Wit
Gewicht verpakking: 188 g
Montagewijze: Plafond
Afmetingen verpakking (BxDxH): 105 x 105 x 55 mm
Type beeldsensor: Passieve infraroodsensor (PIR)
Ingangsspanning: 220 - 240 V
Maximumbereik: 8 m
Afmetingen (B x D x H): 100 x 100 x 45 mm
Bedrijfstemperatuur (T-T): 0 - 40 ยฐC

Heb je hulp nodig?

Als je hulp nodig hebt met HQ EL-PIR70 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Bewegingsdetector HQ

Handleiding Bewegingsdetector

Nieuwste handleidingen voor Bewegingsdetector

Lucide

Lucide Eclips Handleiding

20 November 2024
Megatron

Megatron MT68030 Handleiding

19 November 2024
Megatron

Megatron MT68032 Handleiding

19 November 2024
D-Link

D-Link DCH-S150 Handleiding

16 November 2024
Hager

Hager TXD503 Handleiding

16 November 2024
Maxsa

Maxsa 40234 Handleiding

11 September 2024
Maxsa

Maxsa 43218 Handleiding

11 September 2024
ORNO

ORNO OR-CR-233 Handleiding

9 September 2024