Hikvision DS-PK1-E-WB Handleiding

Hikvision Alarmsysteem DS-PK1-E-WB

Lees hieronder de 📖 handleiding in het Nederlandse voor Hikvision DS-PK1-E-WB (4 pagina's) in de categorie Alarmsysteem. Deze handleiding was nuttig voor 74 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
DS-PK1-E-WE
Wireless LED Keypad
Diagram References
E N G L I S H
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change,
without notice, due to rmware updates or other reasons. Please nd the latest version of this Manual at the Hikvision website (https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
1Introduction
2
Appearance
3Indication
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Directive 2014/30/EU, the RE
Directive 2014/53/EU, the RoHS Directive 2011/65/EU.
replacement of a battery with an i ncorrect type that can defeat a safeguard (for example, in the case of some lithium
battery types);
disposal of a battery into re or a hot oven, or mechanically crushing or cutting of a battery, that can result in an
explosion;
– leaving a battery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of ammable liquid or gas; and
– a battery subjected to extremely low air pressure that may result in an explosion or the leakage of ammable liquid
or gas
Fault
Fire Alarm
Relay Control
Disarm
Away Arm
Stay Arm
Panic Alarm
Medical Alarm
Armed/Disarmed
Enrollment/Signal Strength
Enrollment
With Fault
LED Indication Description
Buzzer Description
Armed
Disarmed
Arming Failed
Disarming Failed
Operation completed: Beep twice
Operation failed: Beep three times
Solid orange for 3 s and then o
Solid blue for 5 s
Green ashes 2 times
Blue turns O
Green turns O
Tampering Alarm
No Alarm
Event Alarm
Note: Event Alarm Priority > Tampering Alarm Priority
Solid red
O
Flashing red
ONo Fault
Signal Strength
Find Me
Power On
Back Light
-If the keypad is not enrolled to the control panel, the back light is o.
-It turns o when there is no key operation for more than 10 s.
Alarm
Tamper Switch
Power Switch
Serial Port
Solid green for 3 s: Strong
Solid orange for 3 s: Medium
Solid red for 3 s: Weak
Flashing red for 3 s: Disconnected
Flashing red and green: Enrolling
Green ashes 7 times: Enrolled
Solid green for 1 s: Powered on
Flashing green for 20 s: Operating
-The back light is on by default, you can set the On/O schedule on
the
web client of the control panel. Refer to the user manual of control
2012/19/EU (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see:
www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentation for specic battery information. The battery is marked
with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recy-
clethis.info
1
CAUTION
RISK OF EXPLOSION IF BATTERY
IS REPLACED BY AN INCORRECT
TYPE.
REPLACEMENT OF A BATTERY
WITH AN INCORRECT TYPE THAT
CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER
DO NOT SWALLOW THE
BATTERY
KEEP NEW AND USED
BATTERIES AWAY FROM THE
CHILDREN.
IF YOU THINK BATTERIES MIGHT
HAVE BEEN SWALLOWED OR
PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE
MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUC-
TIONS AND LOCAL REGULATION.
EN 50131-1:2006+A2:2017
EN 50131-3:2009
EN 50131-5-3:2017
Security Grade(SG) 2
Environmental Class(EC) II
4Enrollment
5Installation
2. Attach the front panel onto the rear panel.
Note: The additional force shall be equal to three times the weight of the equipment but not less than 50N. The equipment
and its associated mounting means shall remain secure during the installation. After the installation, the equipment, including
any associated mounting plate, shall not be damaged.
1. Secure the rear panel on the wall with
four supplied screws.
3. Tighten the screw on the
bottom to complete the
Enroll the Peripheral Locally
Enroll the Peripheral with QR Code or Serial No.
1. In the APP, tap the "Enrollment Mode" button on the control panel page to make the control panel enter the enroll-
ment status.
2. Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.
1. In the APP, tap the icon "+"and scan the QR code or enter the serial No. on the peripheral.
2. Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.
1. Remove the screw on the bottom of the keypad.
2. Disassemble the keypad and remove the rear panel.
3. Power on the security control panel.
4. Log in the Hik-Connect APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the
control panel.
5. Enroll the peripheral locally, with OR code, or with serial No..
Note: for re-enrollment, you need to hold the tamper button while powering the peripheral on simultaneously.
Remove the screw on the bottom of the keypad.
Disassemble the keypad and remove the rear panel. Scan the QR code on the rear panel of the keypad. Push the power switch to ON.
Check signal strength and select installation place
Enter the signal checking mode by operating on the control panel.
Signal LED turns green for 3 s: Strong.
Signal LED turns orange for 3 s: Medium.
Signal LED turns red for 3 s: Weak.
Signal LED ashes red for 3 s: Disconnected.
2
CAUTION
IF THE BATTERY COMPARTMENT
DOES NOT CLOSE SECURETLY,
STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.
7Specication
Command
6
The keypad command is shown as follows.
The keypad technical specication is shown as follows.
Events Codes Notes
Away arming for all areas:
User password + Away
Away arming for specied area:
User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012....)
+ away
-The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter " 0XX"for the No."0"indicates
tens digits, and "XX"indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0 will
ashes three times.
Stay arming for all areas:
User password + Stay
Stay arming for specied area:
User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012....)
+ Stay
-The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter " 0XX"for the No.."0"indicates
tens digits, and "XX"indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0 will
ashes three times.
Disarming for all areas:
User password + Disarm
Disarming for specied area:
User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012....)
+ Disarm
-The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter " 0XX"for the No.."0"indicates
tens digits, and "XX"indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will
ashes three times.
Clear alarm User Password+Hold Disarm
Fire Hold "1/Fire Alarm" for 3 s The Buzzer will beep three times for failure operation.
PA Hold "2/Panic Alarm" for 3 s The Buzzer will beep three times for failure operation.
Medical Hold "3/Medical" for 3 s The Buzzer will beep three times for failure operation.
Duress (Duress Code)+disarm You can set the duress code on the web client of the control panel. Refer to
the user manual of control panel for details.
Output
User Password+Output+relay
No.(1,2.3.4.5.6.7.8.9.010.011.012....)+
-If the relay No. is greater than 9, enter " 0XX" for the No.."0"indicates tens
digits, and "XX"indicates the actual relay No.
- A successful command execution implement an operation "O" or "On".
Away arm
Stay arm
Disarm
3
Speed 42Kbps
Frequency 868.0MHz
Method 2GFSK
Distance 1200m (open area)
Transmition power 13 dbm
Tamper switch 1, front and rear panel tamper-proof
Wireless module For wireless communication
Power switch Power on/o
Buzzer 1
Indicator 4: fault (orange), enrollment/signal (red/green),
arming(red/green/blue), and alarm (red)
Backlight white
Number key 10: 0 to 9
Function key 5: *, #, stay arming, away arming, disarming, and
Humidity 10 to 90% %
Temperature 10 to +55﹣ ℃
Color White/Black
Dimension(W x H x D) 140 x 86 x 22 mm,
Installation Installation Screw mounting
Power Supply Power Supply
1.5 VDC, four AA baterries, standby time more
than two years
Weight Weight without
batteries 151 g, and 23 g each battery
Operation
Environment
Appearance
Wireless Keypad
RF
Interface
Display
Key


Product specificaties

Merk: Hikvision
Categorie: Alarmsysteem
Model: DS-PK1-E-WB

Heb je hulp nodig?

Als je hulp nodig hebt met Hikvision DS-PK1-E-WB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Alarmsysteem Hikvision

Handleiding Alarmsysteem

Nieuwste handleidingen voor Alarmsysteem