Hikvision DS-PDSMK-S-WB Handleiding
Hikvision
Alarmsysteem
DS-PDSMK-S-WB
Lees hieronder de 📖 handleiding in het Nederlandse voor Hikvision DS-PDSMK-S-WB (9 pagina's) in de categorie Alarmsysteem. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/9
1Appearance
T
E
S
T
/
H
U
S
H
Test/Hush Buon
Indicator
Coding Buon
Power Switch
DS-PDSMK-S-WB
Wireless Photoelectric Smoke Detector
Diagram References
E N G L I S H
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instrucons for using and managing the Product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change,
without noce, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (hps://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporng the Product.
and other Hikvision's trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned are the properes of their respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Direcve 2014/30/EU, the RE
Direcve 2014/53/EU, the RoHS Direcve 2011/65/EU.
replacement of a baery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium
baery types);
– disposal of a baery into fire or a hot oven, or mechanically crushing or cung of a baery, that can result in an
explosion;
– leaving a baery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a baery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid
or gas
2012/19/EU (WEEE direcve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentaon for specific baery informaon. The baery is marked
with this symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the baery to your supplier or to a designated collecon point. For more informaon see:www.recy-
clethis.info
replacement of a baery with an incorrect type that can defeat a safeguard (for example, in the
case of some lithium baery types);
– disposal of a baery into fire or a hot oven, or mechanically crushing or cung of a baery,
that can result in an explosion;
– leaving a baery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a baery subjected to extremely low air pressure that may result in an explosion or the
leakage of flammable liquid or gas
The addional force shall be equal to three mes the weight of the
equipment but not less than 50N. The equipment and its
associated mounng means shall remain secure during the
installaon. Aer the installaon, the equipment, including any
associated mounng plate, shall not be damaged.
INSTALLATION CAUTION
BATTERY CAUTION
Chemical burning danger
Do not swallow the baery.
Keep new and used baeries away from the children.
If you think baeries might have been swallowed or placed inside any part of the
body, seek immediate medical aenon.
Risk of explosion if baery is replaced by an incorrect type.
Replacement of a baery with an incorrect type that can defeat a safeguard.
Dispose of used baeries according to the instrucons and local regulaon.
If the baery compartment does not close securely, stop using the product and keep it away from children.
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful
interference to radio or television recepon, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon.
2
Audible and Visual Alarm Indicators
When operang normally, a red LED adjacent to the Test buon will flash every 320 s. When smoke is detected, an internal sounder will acvate to alert occupants, and
the LED will flash rapidly. The sounder is a loud, pulsang alarm and produces a repeang Temporal 3 audible signal paern (0.5 s on, 0.5 s off for 3 cycles, followed by
1.5 s off, repeang).
Test/Hush BuonWhen there is no alarm present, hold the Test/Hush buon will acvate the smoke alarm to check its operaon. The alarm will sound and the LED will
flash rapidly. The unit will return to normal condion in about 10 s when the test is completed.
When the smoke alarm is in the Alarm condion, press the Test/Hush buon will hush the smoke alarm for approximately 11 min. The Hush feature should only be
used aer the cause of the alarm is known (such as normal cooking fumes). The Hush feature allows me for the smoke to clear. During the hush me, the LED will flash
twice every second. Aer the Hush me has expired, the smoke alarm will return to normal sensivity. If smoke is sll present in the unit, the alarm will re-acvate. The
Hush feature can be used repeatedly.
Smoke Chamber Fault
The detector monitors the condion of the smoke sensing chamber. If the smoke sensing chamber ceases to operate normally, the smoke alarm will emit a short
audible signal, then followed by a single Red LED indicator flash, repeang every 40 s. In this case, try vacuuming clean the detector to remove dust. If the condion
persists, replace the detector with a new unit.
Low Baery
When the baery is depleted, the detector will emit a short audible signal and the Red LED indicator flash, repeang every 40 s for at least 30 days. Interconnected
detector will also emit two short audible signals and the Red LED indicator will flash twice, repeang every 4 hours. When the Low Baery signal is given, replaced the
detector with a new unit.
Interconnecon
Wireless interconnecon allows up to 12 detectors to be connected together. Interconnected detector will acvate sounders on all units if any smoke alarm detector. In
this case, only the detector that detected smoke will flash the Red LED. This allows the home owner to quickly locate the cause of the alarm.
Local alarm memory
Aer alarm occurs, the green LED gives 3 flashes every 40 s up to 24 h, which stops flashing aer 24 hours. Any me before the next alarm, press the Test buon, the
detector shall emit 3 audible beeps every 1 s. Release of the Test buon shall reset the alarm.
Funcon
3Enrollment
1. Log in the Hik-ProConnect, and select a site.
2. Select the AX PRO in the site.
3. Enter“Sengs-System Sengs” , and tap the "Enrollment Mode" buon to make the AX PRO enter the enrollemnt status.
4. Turn the power switch of the peripheral on to enrolled it to the control panel.
Enroll the Detector Locally
Register the Detector via APP
1. Log in the Hik-ProConnect, and select a site.
2. Select the AX PRO in the site.
3. Tap the “+” icon on the boom of the page, and scan the QR code to add the peripheral.
4. Turn the power switch of the peripheral on, and it will be automacally enrolled to the control panel.
1
2
xxxx
Device
3
Locaon and number of smoke alarms may be specified in relevant regulaons. Where these do not exist, the requirements of DIN 14676 can be used.
Before commencing installaon, ensure all equipment and tools to mount and test the device are available, such as drills, mounng screws (supplied), cables
and ladders.
Smoke alarm are to be used as minimum requirement in all bedrooms, children's rooms and hallways which act as escape routes, and are to be installed
in each case in the middle of the room, on the ceiling only (do not install on wall).
Select the installaon locaon with a minimum distance of 50 cm to surrounding walls, furniture and lamps.
According to German applicaon standard DIN 14676
Locaon Selecon
Equipment
Installaon
2
1
Configuraon is opmal when devices are also located in all other rooms as well as staircases.
In kitchens and wet rooms, smoke alarms are only used when false alarm caused by the characteriscs of these space are excluded.
Please observe the graphics in this guide.
Install smoke alarms as close to the centre of the ceiling as possible, away from light fings and air-condioning ducts. If this is not praccal, put the alarm on the
ceiling, no closer than 50 cm from any wall or corner.
In rooms with ceiling slopes> 20 °, the smoke alarm shall be mounted at least 0.5 m and not more than 1 m away from the ceiling peak.
Ceilings with a slope angle ≤ 20 ° should be treated as horizontal ceiling.
Installaon Locaon
Rooms with sloped ceiling
4
BEDROOM
CHILDREN’S
BEDROOM
CHILDREN’S
BEDROOM
LIVING ROOM
BATH-
ROOM KITCHEN
CHILDREN’S
BEDROOM
KITCHEN
WORKSHO
P
BOILER ROOM
LIVING ROOM
BEDROOM
Figure 1 b) Example of the applicaon in a typical single-family house
Figure 1 a) Example of the applicaon in a flat
Hold the coding buon and power the detector on at the same me. The detector will be formaed aer 8 s.
Format
Product specificaties
Merk: | Hikvision |
Categorie: | Alarmsysteem |
Model: | DS-PDSMK-S-WB |
Heb je hulp nodig?
Als je hulp nodig hebt met Hikvision DS-PDSMK-S-WB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Alarmsysteem Hikvision
17 April 2024
17 April 2024
12 Maart 2024
4 Augustus 2023
4 Augustus 2023
4 Augustus 2023
4 Augustus 2023
4 Augustus 2023
4 Augustus 2023
4 Augustus 2023
Handleiding Alarmsysteem
- Alarmsysteem Bosch
- Alarmsysteem IKEA
- Alarmsysteem Gigaset
- Alarmsysteem Honeywell
- Alarmsysteem Abus
- Alarmsysteem Apc
- Alarmsysteem Basetech
- Alarmsysteem Blaupunkt
- Alarmsysteem Brennenstuhl
- Alarmsysteem Burg-Wachter
- Alarmsysteem DESQ
- Alarmsysteem Dometic
- Alarmsysteem Doro
- Alarmsysteem Elektrobock
- Alarmsysteem Elro
- Alarmsysteem Eminent
- Alarmsysteem Eufy
- Alarmsysteem Ezviz
- Alarmsysteem FireAngel
- Alarmsysteem Grothe
- Alarmsysteem Hager
- Alarmsysteem Hama
- Alarmsysteem KlikaanKlikuit
- Alarmsysteem Kodak
- Alarmsysteem Konig
- Alarmsysteem Monacor
- Alarmsysteem Nedis
- Alarmsysteem Protector
- Alarmsysteem Pyle
- Alarmsysteem RCF
- Alarmsysteem Redmond
- Alarmsysteem Renkforce
- Alarmsysteem Ring
- Alarmsysteem Schneider
- Alarmsysteem Smartwares
- Alarmsysteem Somfy
- Alarmsysteem Velleman
- Alarmsysteem Vivanco
- Alarmsysteem Woonveilig
- Alarmsysteem X4-Tech
- Alarmsysteem Xavax
- Alarmsysteem Yale
- Alarmsysteem Olympia
- Alarmsysteem Schwaiger
- Alarmsysteem Steren
- Alarmsysteem Imou
- Alarmsysteem Techly
- Alarmsysteem DSC
- Alarmsysteem M-e
- Alarmsysteem Chacon
- Alarmsysteem Swann
- Alarmsysteem EVOLVEO
- Alarmsysteem Electia
- Alarmsysteem Dahua Technology
- Alarmsysteem Gripo
- Alarmsysteem FBT
- Alarmsysteem Chuango
- Alarmsysteem ORNO
- Alarmsysteem ETiger
- Alarmsysteem Werma
- Alarmsysteem Greisinger
- Alarmsysteem Vimar
- Alarmsysteem Kemo
- Alarmsysteem Tzumi
- Alarmsysteem ConiuGo
- Alarmsysteem Olymp
- Alarmsysteem Pentatech
- Alarmsysteem Schabus
- Alarmsysteem Cordes
- Alarmsysteem Qolsys
- Alarmsysteem Bearware
Nieuwste handleidingen voor Alarmsysteem
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024
3 December 2024