Hikvision DS-PDMCK-EG2-WB Handleiding

Hikvision Deur-/raamsensor DS-PDMCK-EG2-WB

Lees hieronder de 📖 handleiding in het Nederlandse voor Hikvision DS-PDMCK-EG2-WB (6 pagina's) in de categorie Deur-/raamsensor. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
DS-PDMCK-EG2-WB
Wireless Magnet Shock Detector
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instrucons for using and managing the Product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change,
without noce, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (hps://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporng the Product.
and other Hikvision's trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned are the properes of their respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
1
The sensor can detect the door or window opening. When the door or window is open, an alarm will be triggered and it will be sent to the alarm center or mobile client
via security control panel.
Door Magnec Sensor Alarm: When the distance between the sensor and the magnet is longer than 3 cm, an alarm will be triggered. The indicator will flash once.
Tamper Alarm: When removing the sensor, an alarm will be triggered.
Introducon
Appearance
2
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Direcve 2014/30/EU, RE
Direcve 2014/53/EU, the RoHS Direcve 2011/65/EU.
BATTERY CAUTION
-Risk of explosion if the baery is replaced by an incorrect type.
-Improper replacement of the baery with an incorrect type may defeat a safeguard (for example, in the case of some
lithium baery types).
-Do not dispose of the baery into fire or a hot oven, or mechanically crush or cut the baery, which may result in an
explosion.
-Do not leave the baery in an extremely high temperature surrounding environment, which may result in an
explosion or the leakage of flammable liquid or gas.
-Do not subject the baery to extremely low air pressure, which may result in an explosion or the leakage of
flammable liquid or gas.
-Dispose of used baeries according to the instrucons.
+idenfies the posive terminal(s) of equipment which is used with, or generates direct current. - idenfies the
negave terminal(s) of equipment which is used with, or generates direct current.
2012/19/EU (WEEE direcve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that
cannot be disposed of as unsorted municipal waste in the European
Union. See the product documentaon for specific baery
informaon. The baery is marked with this symbol, which may
include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).
For proper recycling, return the baery to your supplier or to a
designated collecon point. For more informaon see:www.recycle-
this.info
CAUTION
RISK OF EXPLOSION IF BATTERY
IS REPLACED BY AN INCORRECT
TYPE.
REPLACEMENT OF A BATTERY
WITH AN INCORRECT TYPE THAT
CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER
DO NOT SWALLOW THE
BATTERY
KEEP NEW AND USED
BATTERIES AWAY FROM THE
CHILDREN.
IF YOU THINK BATTERIES MIGHT
HAVE BEEN SWALLOWED OR
PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE
MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUC-
TIONS AND LOCAL REGULATION.
3
12
4
5
6
7
Indicator
Alarm Detecon: Red LED flashes.
Detector Formaed: Red LED flashes 3 mes.
3
4TAMPER Buon
Tampering Alarm: If the detector is disassembled, an alarm will be triggered.
Formang: Restore the device to default sengs.
Power Switch
External Input
Baery
Shock Sensor
2
5
6
7
Posioning Line
1Magnet
1
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
8
8
In the use of the product, you must be in strict compliance with the electrical safety regulaons of the naon and region.
INSTALLATION CAUTION
-Install the equipment according to the instrucons in this manual.
-To prevent injury, this equipment must be securely aached to the floor/wall in accordance with the installaon
instrucons.
-The addional force shall be equal to three mes the weight of the equipment but not less than 50N. The
equipment and its associated mounng means shall remain secure during the installaon. Aer the installaon, the
equipment, including any associated mounng plate, shall not be damaged.
-No naked flame sources, such as lighted candles, should be placed on the equipment.
FCC Informaon
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could void the users authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon
against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful
interference to radio communicaons. However, there is no guarantee that interference will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
FCC Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon
Dig the groove to disassemble the device. Remove the front and rear panel. Turn the power switch to ON to power on the device.
Note: Do not disassemble the device with sharps.
3Power On
4Enrollment
1Enroll the Peripheral Locally
2Enroll the Peripheral with QR and serial No.
1. Log in to the APP Store, download and install the App.
2. Power on the security control panel.
3. Log in the APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel.
1. In the APP, tap the "Enrollment Mode" buon on the control panel page to make the control panel enter the
enrollment status.
2. Power on the peripheral, and it will be automacally enrolled to the control panel.
1. In the APP, tap the icon "+"and scan the QR code or serial No. on the peripheral.
2. Power on the peripheral, and it will be automacally enrolled to the control panel.
CAUTION
IF THE BATTERY COMPARTMENT
DOES NOT CLOSE SECURELY,
STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.
xxxx
Device
5Test
The contact starts test automacally aer being enrolled to the AX PRO. The LED turn red.
Separate the contact, and make a gap between the sensor and magnet. while the LED turns green, the alarm is triggered by this gap. Adjust the installaon
posion of the contact to get a sasfied alarm gap.
The alarm will be triggered while the gap between the sensor and magnet is bigger than that shows in the table. The LED keeps blue for 2 s.
Magnet Detecon Performance Table
2
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
11 13
15 17
11 13
15 19
33 28
28 23
43 42
40 38
37 35
32 30
Without Nominal Distance With Nominal Distance 5mm
Distance in Air Distance in Air
Remove
Approach
Remove
Approach
Remove
Approach
Remove
Approach
Remove
Approach
Event
X+
X-
Y
Z+
Z-
Axes of
Operaon
Magnet Test
1
3 min
Z
X
Y
X
3
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Magnet Test
Start
Knock the door. Adjust the sensivity of the detector unl the blue LED keeps blue for 2 s.
Shock Test
2
Shock Test
Start
Sensivity Suggested scenarios
High Concrete
Normal Wood
Low Window
Tilt the detector more than the set angle, unl the LED keeps blue for 2 s.
You can set the lt angle (5° to 25°) in the mobile client soware.
Note: The lt detecon is only applicable to horizontal or vercal scenes. The lt angle is perpendicular to the
geocentric direcon as the reference standard.
Tilt Test
3
Tilt Test
Start


Product specificaties

Merk: Hikvision
Categorie: Deur-/raamsensor
Model: DS-PDMCK-EG2-WB
Kleur van het product: Wit
Gewicht: 60 g
Connectiviteitstechnologie: Draadloos
Accu/Batterij voltage: 3 V
Ondersteund aantal accu's/batterijen: 1
Geschikt voor: Deur/raam
Interface: RF Draadloos
Ondersteunde beveiligingsalgoritmen: 128-bit AES
Frequentie: 433 MHz
Transmissie-afstand: 1000 m
Bedrijfstemperatuur (T-T): -10 - 55 °C
Relatieve vochtigheid in bedrijf (V-V): 10 - 90 procent
Type batterij: CR123A
Detectie hoek: 25 °

Heb je hulp nodig?

Als je hulp nodig hebt met Hikvision DS-PDMCK-EG2-WB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Deur-/raamsensor Hikvision

Handleiding Deur-/raamsensor

Nieuwste handleidingen voor Deur-/raamsensor