Henry Engineering SUPERELAY II Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Henry Engineering SUPERELAY II (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
SUPERELAY II
UTILITY CONTROL INTERFACE
DESCRIPTION
SUPERELAY II is a utility control interface that provides switching and control functions in a broadcast studio, control
room, A/V system, or any installation requiring multiple circuit control. Superelay II provides three types of outputs:
isolated relay contacts, switched AC, and switched DC. Six SPDT relay contacts can be used for audio, low voltage, or
"dry circuit" switching. The switched AC output can control up to 200 watts of AC load. The switched DC output can
supply 12 vdc at up to 300 ma; it can also “sink” up to 1 amp if used with an external power source. Both switched AC and
DC outputs can be set to “flash” when ON for use with ON THE AIR warning lights. All control, relay output, and DC
output connections are via plug-in euroblock connectors. The AC output is via a standard three-prong grounded outlet.
WARNING! For 230V operation, change mains voltage jumpers before connecting to AC power!
Remove jumpers between E6 & E7, and between E5 & E8. Install a jumper between E5 & E6 for 230V; replace fuse F1
with .125a fuse. See schematic on reverse side. Jumpers should be changed by a qualified technician only.
INSTALLATION
Connection to Control inputs and low voltage relays is via plug-in connectors. Remove about 1/8” of the insulation, insert
wires into the connector, and tighten the screws. Be sure that no bare wires are exposed.
CONTROL INPUTS: Superelay can be switched ON and OFF by either a momentary or maintained ground closure, or by
application of an external DC voltage.
For control with a ground closure: A momentary closure between the ON and G terminals will turn the unit ON.
A momentary closure between OFF and G will reset it OFF.
For control with a maintained closure install a jumper between the OFF and G terminals.
A maintained closure between ON and G will turn the unit ON; removing the closure will reset it OFF.
The ground closure can be a relay or switch contact, open collector, CMOS or TTL gate, opto-isolator, or any other circuit
that switches to ground. The red TALLY-ON LED will light to indicate the ON state.
For control with a DC voltage: Superelay can be controlled by applying an external DC voltage to the IN+ and G
terminals. Any DC voltage between 5 and 24 volts will switch the unit ON. This input is opto-isolated. Observe polarity.
RELAY OUTPUTS: Superelay provides six SPDT relay contacts for utility use. All six relays operate simultaneously. The
C and NO terminals are active when then unit is ON; the C and NC terminals are active when the unit is OFF. These
relays can switch up to 1 amp at 24 volts DC. (Do NOT use these relay outputs to switch AC line voltage!)
AC TALLY LIGHT OUTPUT: Superelay also provides a TALLY output that supplies AC line voltage for incandescent
warning lights when the unit is ON. (Do not use florescent lights.) The TALLY output will flash if the front panel FLASH
switch is set to ON. The Tally output load should not exceed 200 watts. The TALLLY LIGHTS FUSE, accessible from the
rear panel, will blow if this limit is exceeded. (Replace with a 2A AGC fuse.) Note: The low voltage relays will continue to
operate even if the Tally Lights fuse blows.
NOTE: It is normal for there to be a slight amount of leakage current through the AC output if no output load is plugged into the AC socket.
If the AC output is measured with an AC voltmeter, it will show line voltage present even if the unit is OFF. This is normal; plugging a light bulb or other
load into the AC socket will eliminate this false reading.
LED TALLY LIGHT OUTPUT: Superelay can control low-voltage LED Tally lights. The unit can directly power LED Tally
lights that require 12 vdc, 300 ma or less. Connect the Superelay 12V terminal to the + wire of the light; connect the
– wire of the light to the LED terminal on the Superelay.
For LED Tally lights that require more than 12 vdc or 300 ma, use an external power source connected as follows:
Connect the + voltage source directly to the + wire of the light. Connect the ground of the power source to the G terminal
of the Superelay, and connect the – wire of the light to the LED terminal on the Superelay.
The 12V terminal provides 12 volts DC for utility use, 300 ma maximum.
Rev. D: 9/2015
HENRY ENGINEERING
PO Box 3796
Seal Beach, CA 90740
Tel: 562.493.3589
www.henryeng.com
D
65 4 3 2
C
B
A
SECPRI
BLK
115V
230V
AC
AC WHT
GRN
C
1
2
NO
NO
C
NC
C
NC
3
4
NO
NO
C
NC
RELAY OUTPUT RELAY OUTPUT
CONTROL
NC
ON
OFF
GND
DC
+12V
LED
F2-TIP F2-SIDE
1
2
3
4
5
6
J2
+C1
2000uF 25V
C3
.1uF 50V
E7
E1
R10
1 MEG
R5
47K
F2
2 AMP
1
TP2
E8
E2
R4
47K
LED1
1
2
3
4
5
6
J1
1
2
3
4
5
6
J3
1
TP1
R3
10K
R2 100
R9 1.5K
R1 100
D2 1N4004
E5
F1
115V: 250 ma; 230V: 125ma
4
6
8
13
11
9
1
16
K1
DPDT 12VDC
1
3
4
2
5
6
8
7
T1
SPW-153
C4
.1uF 50V
R12
1.5K
1 6
2
5
4
U3
4N25
D1 1N4004
E6
4
6
8
13
11
9
1
16
K2
DPDT 12VDC
D4
1N4004
+
C7
2000uF 25V
1
2
3
U1-A
CD4011
5
6
4
U1-B
CD4011
8
9U1
CD40
12
13
11
U1-D
CD4011
3IN
2
GND
1
OUT
Q3 LM78L05ACZ
E9 E10
D5 1N4004
D6 1N4004
+12V
+12V
VCC
VCC
VCC
VCC
+12V +12V
A


Product specificaties

Merk: Henry Engineering
Categorie: Niet gecategoriseerd
Model: SUPERELAY II

Heb je hulp nodig?

Als je hulp nodig hebt met Henry Engineering SUPERELAY II stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Henry Engineering

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd