Heatit Z-RELAY Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Heatit Z-RELAY (10 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
Ver 2018-C
2 yr
Heatit Controls AB, SE-Läkarvägen 4
454 31 BRASTAD, SWEDEN, Phone: +47 61 18 77 77
post@heatit.com www.heatit.com
HEATIT
Z-RELAY Manual
01.01.2018
Multipurpose Relay Firmware version: 0.12
1. PRODUCT DESCRIPTION
2. INSTALLATION GUIDELINES
2.1 Inputs
2.1.1 Temperature inputs
2.1.2 Flood sensor input
2.2 Relay output
3. BEHAVIOR WITHIN THE Z-WAVE NETWORK
4. FACTORY RESET
5. ASSOCIATION GROUPS
6. SECURITY (S2)
7. CONFIGURATION PARAMETERS
8. COMMAND CLASSES
9. TECHNICAL SPECIFICATION
3
3
4
4
4
5
5
6-8
9
10
CONTENTS
3
1. PRODUCT DESCRIPTION
The Heatit Z-Relay is a Z-Wave module in a water-resistant housing equipped with 10 x membrane cable entries.
The Heatit Z-Relay is equipped with 1 relay output and 3 multi-purpose inputs, and a Z-Wave radio for interfacing to the
wireless Z-Wave network. The module must be power supplied from a 230V AC mains connection.
The Heatit Z-Realy high-duty relay output are able to be freely controlled from the Z-Wave network, and can be used for
several purposes, e.g. control of valve actuators, stoves etc.
Two of the Heatit Z-Relay inputs can be configured to function as either digital inputs or as analogue inputs for interfacing
simple NTC temperature sensors. When the inputs are used as digital inputs, they can be connected to potential free
contacts, open-collector outputs, and will be able to control other Z-Wave devices when the status of the inputs sent
to other Z-Wave devices on the Z-Wave network. The last input can be used as either digital input or be used to be
connected to a flood detector.
It is possible to configure the level- and the indication of the status indicator LED on the modules circuit board.
2. INSTALLATION GUIDELINES
ATTENTION: Only authorized technicians under consideration of the country-specific installation guidelines/norms may
do works with 230 Volt mains power. Prior to the assembly of the product, the voltage network has to be switched off and
ensured against re-switching.
NTC 1 NTC 2
Water Leak Sensor
L
N
AC
LOAD
Inclusion button


Product specificaties

Merk: Heatit
Categorie: Niet gecategoriseerd
Model: Z-RELAY
Kleur van het product: Wit
Stroom: 25 A
Afmetingen (B x D x H): 104 x 46 x 104 mm
Maximum indoorbereik: 40 m
AC-ingangsspanning: 230 V
AC-ingangsfrequentie: 50 - 60 Hz
Bedrijfstemperatuur (T-T): 5 - 40 °C

Heb je hulp nodig?

Als je hulp nodig hebt met Heatit Z-RELAY stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Heatit

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Electrolux

Electrolux STA9 Handleiding

23 November 2024
Electrolux

Electrolux UMP3 Handleiding

23 November 2024
Bosch

Bosch HEZ8TK36UC Handleiding

23 November 2024
Bosch

Bosch HEZ8ZZ36UC Handleiding

23 November 2024
Bosch

Bosch HDZIT301 Handleiding

23 November 2024
Bosch

Bosch HEZBS301 Handleiding

23 November 2024
LG

LG LX-330 Handleiding

23 November 2024
Bosch

Bosch KSZ2AVU00 Handleiding

22 November 2024