Hayward Super II Eco VS Handleiding

Hayward Pomp Super II Eco VS

Lees hieronder de 📖 handleiding in het Nederlandse voor Hayward Super II Eco VS (16 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
Hayward Pool Products (Australia) Pty Ltd.
Melbourne-Sydney-Brisbane-Perth
Email: sales@hayward-pool.com.au | Website: www.hayward-pool.com.au
PO Box 4384 | Dandenong South VIC 3164
ABN 66 083 413 414
Sales Contact Ph: 1300POOLS1 Fax: 1300POOLS2
SAVE THIS INSTRUCTION MANUAL
30-LITINSB0020
Owner’s Manual
To prevent potential injury and to avoid unnecessary service calls
read this manual carefully and completely.
Variable Speed Pump
Super II Economy VS™
SP3011DIVS REV1 30-LITINSB0020.indd 1
SP3011DIVS REV1 30-LITINSB0020.indd 1
SP3011DIVS REV1 30-LITINSB0020.indd 1
SP3011DIVS REV1 30-LITINSB0020.indd 1SP3011DIVS REV1 30-LITINSB0020.indd 1 21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM21/11/2019 3:23:10 PM
2
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF
WARNING
Read and follow all instructions in this owner’s manual and on
the equipment. Failure to follow instructions can cause severe
injury and/or death
WARNING – This manual contains important information about the installation, operation, and safe use of this pump
that must be be transferred through to the end user of this product.
WARNING – This product should be installed and serviced only by a qualified professional.
WARNING – All electrical wiring MUST be performed by a qualified electrical contractor, and must conform to local
electrical regulations and the Latest Edition AS/NZS 3000 Wiring Rules.
WARNING – This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilites, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
DO NOT PLAY WITH THE APPLIANCE.
CAUTION – This pump is intended for use on permanently installed swimming pools and may also be used with hot
tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in or on the ground
or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of
being readily disassembled for storage and reassembled to its original integrity. Though this product is designed for outdoor
use, it is strongly advised to protect the electrical components from the weather. Select a well-drained area, one that will
not flood when it rains. It requires free circulation of air for cooling. Do not install in a damp or non-ventilated location. If
installed within an outer enclosure or beneath the skirt of a hot tub or spa, adequate ventilation and free circulation of air
must be provided to prevent overheating of the motor.
WARNING – Pool and spa components have a finite life. All components should be inspected frequently and
replaced at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached.
WARNING – Risk of Electric Shock. All electrical wiring must be performed by a qualified
electrical contractor, and must conform to Local/State/Federal electrical regulations and the Latest
Edition AS/NZ 3000 Wiring Rules. All electrical circuits must be supplied through a Residual Current
Device - RCD (Safety Switch), with a residual operating current of 30 mA. Hazardous voltage can
shock, burn and cause death or serious property damage. To reduce the risk of electric shock, do NOT
use an extension cord to connect unit to the electricity supply.
WARNING – To reduce the risk of electric shock replace damaged wiring immediately. Locate the power cord so that
it cannot be damaged by lawn mowers, hedge trimmers and other equipment.
WARNING – Never operate the circulation system at more than (50 PSI) 344 kPa maximum.
WARNING – Automatic Restart. The pump motor is automatically protected from overload and overheating. If such
an error occurs the controller will automatically try to restart the pump. If a power failure occurs while the pump is running,
it will automatically restart once the power has been restored.
SP3011DIVS REV1 30-LITINSB0020.indd 2
SP3011DIVS REV1 30-LITINSB0020.indd 2
SP3011DIVS REV1 30-LITINSB0020.indd 2
SP3011DIVS REV1 30-LITINSB0020.indd 2SP3011DIVS REV1 30-LITINSB0020.indd 2 21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM21/11/2019 3:23:10 PM
3
USE ONLY HAYWARD ® GENUINE REPLACEMENT PARTS
IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF
WARNING – Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during
start-up, normal operation, and after pump shut-off. Stand clear of circulation system equipment during
pump start-up. Failure to follow safety and operation instructions could result in violent separation
of the pump housing and cover due to pressure in the system. This separation could cause property
damage, severe personal injury, or death. Before servicing the pool and spa water circulation system, all
system and pump controls must be in the off position and the Filter Manual Air Relief Valve must be in
the open position. Before starting the system pump, all valves must be set in a position to allow system
water to return back to the pool. Do not change the Filter Control Valve position while the system pump
is running. Before starting the system pump, fully open the Filter Manual Air Relief Valve. Do not close
the Filter Manual Air Relief valve until all the air is expelled and a steady stream of water is discharged
from the valve. All suction and discharge valves when starting the circulation system. MUST BE OPEN
Failure to do so could result in severe personal injury and/or property damage.
WARNING – Separation Hazard. Failure to follow safety and operation instructions could result in violent separation
of pump components. Strainer cover must be properly secured to pump housing with the strainer cover
lock ring. Before servicing pool and spa circulation system, all system and pump controls must be in
off position and the Filter Manual Air Relief Valve must be in open position. Do not operate pool and
spa circulation system if system components are not assembled properly, damaged, or missing. Do
not operate pool and spa circulation system unless the Filter Air Relief Valve body is in locked position
within the filter upper body. All suction and discharge valves MUST BE OPEN when starting the
circulation system. Failure to do so could result in severe personal injury and/or property damage.
WARNING – Suction Entrapment Hazard. The force from suction in suction outlets and/or suction outlet covers which
are damaged, broken, cracked, missing, or unsecured, can cause severe injury and/or death due to the
following entrapment hazards:
Hair Entrapment - Hair can become entangled in suction outlet cover.
Limb Entrapment - A limb inserted into an opening of a suction outlet sump or suction outlet cover
that is damaged, broken, cracked, missing, or not securely attached, can result in a mechanical bind or
swelling of the limb.
Body Suction Entrapment - A differential pressure applied to a large portion of the body or limbs can
result in an entrapment.
Evisceration/Disembowelment - A negative pressure applied directly to the intestines through an
unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or
unsecured, can result in evisceration/disembowelment.
Mechanical Entrapment - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or
knuckles, to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.
WARNING – To Reduce the risk of Entrapment Hazards:
»When outlets are small enough to be blocked by a person, a minimum of two functioning
suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or
wall), must be installed a minimum of 0.91 metres or three feet (3’) apart, as measured from
near point to near point to avoid dual blockage by a user.
»Dual suction fittings shall not be located on seating areas or on the backrest for such
seating areas.
»Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing,
or not securely attached.
»Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.
»In addition to installing two or more suction outlets per pump, follow all National, State and Local regulations and
AS 1926.3 Latest Edition.
»Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
SP3011DIVS REV1 30-LITINSB0020.indd 3
SP3011DIVS REV1 30-LITINSB0020.indd 3
SP3011DIVS REV1 30-LITINSB0020.indd 3
SP3011DIVS REV1 30-LITINSB0020.indd 3SP3011DIVS REV1 30-LITINSB0020.indd 3 21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM
21/11/2019 3:23:10 PM21/11/2019 3:23:10 PM


Product specificaties

Merk: Hayward
Categorie: Pomp
Model: Super II Eco VS

Heb je hulp nodig?

Als je hulp nodig hebt met Hayward Super II Eco VS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Hayward

Handleiding Pomp

Nieuwste handleidingen voor Pomp