5.34 General Catalogue • Modular Devices • Technical
Electrical Characteristics
Family SF
Modular size 1 module 2 module 4 module
Reference SFH125 SFM125 SFT125 SFH225 SFT225 SFT240 SF263
Thermal current Ith (40°C) 25A 25A 25A 25A 25A 40A 63A
Operational frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Rated operation voltage in AC 230V
Rated insulation voltage (Ui) 440V 440V 440V 440V 440V 440V 500V
Rated impulse withstand voltage
Uimp 4 KV 4 KV 3 KV 6 KV 6 KV 6 KV 4 KV
Protection degree 2223222
Working temperature -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C -20 to 50°C
Storage temperature -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C -40 to 80°C
Operational Currents I
e
Rated voltage Load duty
category
400V AC AC 22A 25A 25A 25A 25A 25A 40A 63A
400V AC AC 22B 25A 25A 25A 25A 25A 40A 63A
Short circuit characteristic
Rated short time withstand cur-
rent 1s Icw (rms) IEC 60947-3 375A / 1sec 600A /
1sec
4.5kA
cond.
Prospective short circuit current
(rms) EN 60669 3kA 3kA 3kA 6kA 6kA n/a n/a
Mechanical characteristic
Rigid cable section 35 mm 35 mm 35mm 25 mm 25 mm 25 mm 25 mm2 2 2 2 2 2 2
flexible cable section 10 mm 10 mm 10 mm 16 mm 16 mm 16 mm 16 mm2222222
Tightening torque 1.8 Nm 1.8 Nm 1.8 Nm 1.8 Nm 1.8 Nm 1.8 Nm 1.8 Nm
IP protection degree 20 20 20 20 20 20 20
Mechanical endurance (number
of cycle) 200,000 200,000 200,000 200,000 200,000 200,000 100,000
Electrical endurance @ AC22
(number of cyles) 25,000 25,000 25,000 5,000 5,000 2,500 5,000
Overall dimension
Width (mm)17.5 17.5 17.5 35 35 35 71.5
Height (mm) 83 83 83 83 83 83 90
Depth (mm) 68 68 68 68 68 70 68
Modular Changeover Switches


Product specificaties

Merk: Hager
Categorie: Schakelaar
Model: SFH125
Internationale veiligheidscode (IP): IP20
Temperatuur bij opslag: -40 - 80 °C
Frequentie: 50/60 Hz
Bedrijfstemperatuur (T-T): -20 - 50 °C
Spanningclassificatie: 230 V
Aantal polen: 1

Heb je hulp nodig?

Als je hulp nodig hebt met Hager SFH125 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Schakelaar Hager

Handleiding Schakelaar

Nieuwste handleidingen voor Schakelaar