Gossen Metrawatt Metrahit H&E Car Handleiding

Gossen Metrawatt Multimeter Metrahit H&E Car

Lees hieronder de 📖 handleiding in het Nederlandse voor Gossen Metrawatt Metrahit H&E Car (28 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 55 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
Operating Instructions
METRA METRAHIT27 and HITH+E CAR
METRA HIT 27M: Digital Multimeter and Milliohmmeter
METRA HIT 27I: Digital Multimeter, Milliohmmeter and Megohmmeter
METRA HIT H+E CAR: Mega Tester for Hybrid E-cars 3-349-207-02
15/2.19
2 GMC-I Messtechnik GmbH
1 Display (LCD)
2 ON|OFF key
Operating mode menu: open submenus / acknowledge entries
METRA HIT 27I: background illumination ON / OFF
3 DATA| CLEAR key for following functions: save measured value,
delete and MIN/MAX
Operating mode menu: Selection of individual menu items
against direction of flow / increase values
4 MAN|AUTO key for manual measuring range selection
Operating mode menu: Selection of individual menu items
in direction of flow, decrease values
5FUNC key for selecting functions, start key INS measurement
Operating mode menu: Exit menu level and return to a higher level/
exit parameters configuration without saving data
6 Rotary selector switch for measuring function
7 Connector jacks *
8 Connector jacks for mains power battery charger NA HIT 27
( )only with storage batteries inserted
*
Earthing input
S- Sense –, for 4-wire connection only with
Ω
/m
Ω
/m
Ω
@
1A
S+ Sense +, for 4-wire connection only with
Ω/
m
Ω
/m
Ω
@1A
V;
Ω
;
°
C, M
Ω
measurement input
Symbols used in the Digital Display
1 Main display with decimal point and polarity display
2 Auxiliary display with decimal point and polarity display
3 : Multimeter in continuous operation,
ON blinks at transmission frequency in transmission mode
4 REM: Memory mode operation, disappears after communication
via the interface is ended by means of key or switch operation
5 ZERO: Zero balancing
6 MAN: Manual measuring range selection
7 Unit of measure (if blinking, refer to chapter 11.2 on page 16 and
chapter 15 on page 26)
8 MIN/MAX: Display of smallest/largest recorded values
with time specification
9:Acoustic signal enabled,
beeper is activated for corresponding function
10 :
Low recharcheable battery voltage (< 3.3 V), recharge batteries
Standard Equipment
1
2
3
4
5
6
8
7
7
max. 600 V !
Type 27M 27I 27AS
27I Set
H+E
CAR
H+E
CAR
Set
Article Number M227A M227B M227C M227S M227T M227U
Instrument METRA HIT 27M 27I 27I 27I
H+E
CAR
H+E
CAR
3 size AA NiMH storage batteries
••••••
Measurement cable set
KS17-S KS17-S KS17-S KS17-2
— —
operating instructions ••••••
abbreviated operating instructions
••••••
GH18 protective rubber
cover with carrying strap green green green green orange orange
DAkkS calibration certificate
••••••
Charging unit NA HIT 27 •••••
Kelvin clips KC4 (1 set = 2 each)
•••— —
Kelvin prob. KC27 (1 set=2 each)
—— ———
Hard case HC30 — —
Hybrid Diagnostic-Kit
1
10
9
64 53
7
8
2
GMC-I Messtechnik GmbH 3
Table of Contents
Page Page
1 Safety Features and Precautions ...............................4
2 Initial Start-Up ............................................................5
3 Selecting Measuring Functions and Measuring
Ranges .......................................................................6
3.1 Automatic Measuring Range Selection .....................................6
3.2 Manual Measuring Range Selection ......................................... 6
3.3 Quick Measurements .............................................................. 7
4 Triple Digital Display ..................................................7
5 Measured Value Storage ............................................8
5.1 Measured Value Storage – Key Function “DATA”
(Hold/Compare) ......................................................................8
6 Saving Minimum and Maximum Values
“MIN/MAX” with Time Stamp .....................................9
7 Voltage and Frequency Measurement ......................10
7.1 Voltage Measurement [V] ...................................................... 10
7.1.1 Zero Balancing in the 3 V DC Measuring Range ...................... 10
7.2 Frequency Measurement [Hz] ................................................ 10
8 Resistance and Diode Measurements ......................11
8.1 Resistance Measurement (2-wire connection) [Ω] .................. 11
8.1.1 Zero Balancing in the 300 Ω and 3 kΩ Measuring Ranges ..... 11
8.2 Continuity Test during Resistance Measurement .................... 12
8.3 Diode Measurements ........................................................... 12
9 Milliohm Measurement (4-Pole-Measurement) .......13
9.1 Compensation of Cable Resistance ........................................ 13
9.1.1 Measurement with Kelvin Probe KC27 ................................... 13
9.2 Thermovoltage Compensation ................................................ 13
9.3 Milliohm Measurement with 200 mA or 20 mA DC [mΩ] ........ 14
9.4 Milliohm Measurement with 1 A Pulsating Measuring
Current [mΩ@1 A]
(automatic thermovoltage correction in 3
300
m
Ω
range) ...........14
10 Temperature Measurement [°C] ..............................14
11 Insulation Resistance Measurement [MΩ@...V]
(METRA HIT 27I and METRA HIT H+E CAR only) ........15
11.1 Preparing for Measurement ................................................... 15
11.2 Insulation Resistance Measurement ....................................... 16
11.3 Ending the Measurement and Discharging .............................. 16
12 Using the Menus – from the Initial InFO Menu to
Operating and Measuring Parameters .....................17
12.1 Sampling rAtE ........................................................... 17
12.2 Saving Measured Values ....................................................... 17
12.2.1Memory Mode – DATA Key Function (see also chapter 5.1) ..... 17
12.2.2Memory Mode Operation – STORE Menu Function .................. 18
12.3 Querying Memory Occupancy – INFO MEMO/OCCUP ......... 18
12.4 Clearing the Memory – MEMO CLEAr ................................ 18
12.5 Activating the Default Values ................................................. 18
12.6 Transmission Mode Operation with RS 232 Interface .............. 19
13 Characteristic Values .....................................22
14 Maintenance ............................................................25
14.1 Storage Batteries and Batteries ............................................. 25
14.2 Fuses ................................................................................... 26
14.3 Housing ............................................................................... 26
14.4 Device Return and Environmentally Compatible Disposal ......... 26
15 Multimeter Messages .............................................. 26
16 Accessories .............................................................27
17 Repair and Replacement Parts Service,
Calibration Center* and Rental Instrument Service . 27
18 Guarantee ................................................................28
19 Product Support .......................................................28
20 Recalibration ............................................................28


Product specificaties

Merk: Gossen Metrawatt
Categorie: Multimeter
Model: Metrahit H&E Car

Heb je hulp nodig?

Als je hulp nodig hebt met Gossen Metrawatt Metrahit H&E Car stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Gossen Metrawatt

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter