Gossen Metrawatt MetraClip 85 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Gossen Metrawatt MetraClip 85 (42 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 14 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/42
METRA CLIP 85
 CLAMP MULTIMETER
User’s manual
ENGL I S H
Clamp Multimeter METRACLIP 85 English
CONTENTS
1 PRESENTATION............................................................................................................ 7
1.1 THE SWITCH ....................................................................................................................... 8
1.2 THE KEYS OF THE KEYPAD .......................................................................................... 9
1.3 THE DISPLAY UNIT ........................................................................................................ 10
1.3.1 The symbols of the display unit ....................................................................... 11
1.3.2 Measurement capacity exceeded (O.L) .......................................................... 12
1.4 THE TERMINALS ............................................................................................................. 12
2 THE KEYS ..................................................................................................................... 12
2.1 KEY ............................................................................................................................ 13
2.2 KEY ( ) SECOND FUNCTION .......................................................................................... 13
2.3 ............................................................................................................................ KEY 14
2.4 KEY ......................................................................................................................... 14
2.4.1 In the normal mode ......................................................................................... 14
2.4.2 The MAX/MIN mode + activation of the HOLD mode .................................. 15
2.4.3 Access to the True-INRUSH mode ( set to ) ............................... 15
2.5 KEY ............................................................................................................................ 16
2.5.1 The Hz function in the normal model ............................................................. 16
2.5.2 The Hz function + activation of the HOLD mode .......................................... 17
2.6 KEY ......................................................................................................................... 17
3 USE .................................................................................................................................. 18
3.1 COMMISSIONING ........................................................................................................... 18
3.2 STARTING UP THE MULTIMETER CLAMP ............................................................. 18
3.3 SWITCHING THE CLAMP MULTIMETER ................................................................ 18
3.4 CONFIGURATION ........................................................................................................... 19
3.4.1 Programming of the maximum resistance allowed for a continuity.............. 19
3.4.2 De-activation of automatic switching off (Auto Power OFF) ....................... 19
3.4.3 Programming of the current threshold for the True INRUSH measurement 19
3.4.4 Change of temperature measurement unit ..................................................... 20
3.4.5 Programming of the Adapter function scale factor ....................................... 21
3.4.6 Default configuration ...................................................................................... 21
3.5 .................................................................................. VOLTAGE MEASUREMENT (V) 21
3.6 CONTINUITY TEST ................................................................................................... 22
3.6.1 Automatic compensation of the resistance of the leads ................................. 23
3.7 RESISTANCE MEASUREMENT Ω .............................................................................. 23
3.8 DIODE TEST ............................................................................................................... 24
2
English Clamp Multimeter METRACLIP 85
3.9 CURRENT MEASUREMENT (A) .................................................................................. 24
3.9.1 AC measurement ............................................................................................. 24
3.9.2 DC measurement ............................................................................................. 25
3.10 STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT
26
3.11 FREQUENCY ZMEASUREMENT (H ) .......................................................................... 26
3.11.1 Frequency measurement in voltage ................................................................ 27
3.11.2 Frequency measurement in current ................................................................ 27
3.12 TEMPERATURE MEASUREMENT ............................................................................. 28
3.12.1 Measurement without external sensor ............................................................ 28
3.12.2 Measurement with external sensor ................................................................. 28
3.13 ADAPTER FUNCTION MEASUREMENT .................................................................. 29
4 CHARACTERISTICS .................................................................................................. 30
4.1 REFERENCE CONDITIONS ........................................................................................... 30
4.2 CHARACTERISTICS UNDER THE REFERENCE CONDITIONS ......................... 31
4.2.1 DC voltage measurement ................................................................................ 31
4.2.2 AC voltage measurement ................................................................................ 31
4.2.3 DC current measurement ................................................................................ 32
4.2.4 AC current measurement ................................................................................ 32
4.2.5 True-Inrush measurement ............................................................................... 33
4.2.6 Continuity measurement ................................................................................. 33
4.2.7 Resistance measurement ................................................................................. 33
4.2.8 Diode test ......................................................................................................... 34
4.2.9 Frequency measurements................................................................................ 34
4.2.10 Temperature measurement ............................................................................. 35
4.2.11 Adapter function measurement ....................................................................... 35
4.3 ENVIRONMENTAL CONDITIONS .............................................................................. 36
4.4 CHARACTERISTICS OF CONSTRUCTION ............................................................... 37
4.5 ............................................................................................................... POWER SUPPLY 37
4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS........................................ 38
4.7 VARIATIONS THE IN DOMAIN OF USE .................................................................... 38
5 MAINTENANCE .......................................................................................................... 39
5.1 ......................................................................................................................... CLEANING 39
5.2 REPLACEMENT THE BATTERY OF ........................................................................... 39
5.3 METROLOGICAL CHECK ............................................................................................. 40
5.4 REPAIR ............................................................................................................................... 40
6 WARRANTY ................................................................................................................. 40
7 DELIVERY CONDITION ........................................................................................... 41