METRA CLIP 87
 CLAMP MULTIMETER
User’s manual
ENGL I S H
Clamp Multimeter METRACLIP 87 English
CONTENTS
1 PRESENTATION............................................................................................................ 8
1.1
THE
SWITCH ........................................................................................................................................ 9
1.2
THE
KEYS
OF
THE
KEYPAD .......................................................................................................... 10
1.3
THE
DISPLAY
UNIT.......................................................................................................................... 11
1.3.1 The symbols of the display unit ....................................................................... 11
1.3.2 Measurement capacity exceeded (O.L) .......................................................... 13
1.4
THE
TERMINALS .............................................................................................................................. 13
2 THE KEYS ..................................................................................................................... 14
2.1
KEY ....................................................................................................................................................... 14
2.2
KEY
(
SECOND FUNCTION
) ..................................................................................................................... 15
2.3
KEY ....................................................................................................................................................... 15
2.4
KEY ....................................................................................................................................................... 16
2.5
KEY ....................................................................................................................................................... 17
2.5.1 In the normal mode ......................................................................................... 17
2.5.2 Access to the True set to - INRUSH mode ( ) .................................... 18
2.5.3 The MAX/MIN/PEAK mode + activation of the HOLD mode....................... 18
2.6
KEY ....................................................................................................................................................... 19
2.6.1 The Hz function in the normal mode .............................................................. 19
2.6.2 In the display of orders of harmonics mode or + ................. 20
2.6.3 In Hz mode + activation of the HOLD mode ................................................. 20
3 USE.................................................................................................................................. 21
3.1
COMMISSIONING ............................................................................................................................. 21
3.2
STARTING
UP
THE
CLAMP
MULTIMETER .............................................................................. 21
3.3
SWITCHING
THE
CLAMP
MULTIMETER .................................................................................. 22
3.4
CONFIGURATION ............................................................................................................................ 22
3.4.1 De-activation of automatic switching off (Auto Power OFF) ....................... 22
3.4.2 Programming of the current threshold for the True INRUSH measurement 22
3.4.3 Programming the rate of recording in memory ............................................. 23
3.4.4 Erasure of the records in memory .................................................................. 23
3.4.5 Default configuration ...................................................................................... 23
3.5
VOLTAGE
MEASUREMENT
(V) ................................................................................................... 24
3.6
CONTINUITY
TEST
................................................................................................................... 25
3.7
RESISTANCE
MEASUREMENT
Ω
................................................................................................ 26
3.8
CURRENT
MEASUREMENT
(A) ................................................................................................... 26
3.8.1 AC measurement ............................................................................................. 26
3.8.2 DC or AC+DC measurement.......................................................................... 27
3.9
STARTING
CURRENT
OR
OVERCURRENT
(TRUE
INRUSH)
MEASUREMENT ............. 29
3.10
POWER
MEASUREMENTS
W,
VA,
VAR
,
PF
AND
DPF.............................................................. 30
2
English Clamp Multimeter METRACLIP 87
3.10.1 Measurement of single phase power- .............................................................. 31
3.10.2 Balanced three-phase power measurement.................................................... 32
3.10.3 Four quadrant diagram .................................................................................. 33
3.11
ENERGY
METERING
MEASUREMENT...................................................................................... 33
3.12
FREQUENCY
MEASUREMENT
(H
Z
) ............................................................................................37
3.12.1 Frequency measurement in voltage ................................................................ 37
3.12.2 Frequency measurement in current ................................................................ 38
3.13
MEASUREMENT
OF
THE
TOTAL
HARMONIC
DISTORTION
(THD)
AND
DISPLAY
OF
THE
ORDERS
OF
HARMONICS .................................................................................................................... 38
3.13.1 Measurement of the THD in voltage .............................................................. 38
3.13.2 Measurement of the THD in current .............................................................. 39
3.13.3 Display of the 25 orders of harmonics and of the frequency of the
fundamental ..................................................................................................................... 40
3.14
RECORDING
OF
MEASUREMENT
DATA/CAMPAIGNS ....................................................... 41
3.15
PROCESSING
OF
THE
DATA
ON
A
PC
WITH
THE
PAT
SOFTWARE .................................. 41
4 CHARACTERISTICS .......................FEHLER! TEXTMARKE NICHT DEFINIERT.
4.1
REFERENCE
CONDITIONS ............................................................................................................ 55
4.2
CHARACTERISTICS
UNDER
THE
REFERENCE
CONDITIONS ........................................... 55
4.2.1 DC voltage measurement ................................................................................ 56
4.2.2 AC voltage measurement ................................................................................ 56
4.2.3 AC+DC voltage measurement ........................................................................ 57
4.2.4 DC current measurement ................................................................................ 57
4.2.5 AC current measurement ................................................................................ 58
4.2.6 AC+DC intensity measurement ...................................................................... 58
4.2.7 True-Inrush measurement ............................................................................... 59
4.2.8 Calculation of the crest factor (CF) ............................................................... 59
4.2.9 Calculation of the RIPPLE in DC .................................................................. 60
4.2.10 Continuity measurement ................................................................................. 60
4.2.11 Resistance measurement ................................................................................. 60
4.2.12 Active DC power measurements ................................ ..................................... 61
4.2.13 Active AC power measurements ..................................................................... 61
4.2.14 Active AC+DC power measurements ............................................................. 62
4.2.15 Measurement of apparent AC power .............................................................. 63
4.2.16 Measurement of apparent AC+DC power ..................................................... 63
4.2.17 Measurement of reactive AC power ............................................................... 64
4.2.18 Measurement of reactive AC+DC power ....................................................... 65
4.2.19 Calculation of the power factor (PF) ............................................................. 65
4.2.20 Calculation of the displacement power factor (DPF).................................... 66
4.2.21 Frequency measurements................................................................................ 66
4.2.22 Characteristics in THDr ................................................................................. 67
4.2.23 Characteristics in THDf .................................................................................. 67
4.2.24 Harmonic measurement characteristics ......................................................... 67
4.3
ENVIRONMENTAL
CONDITIONS ............................................................................................... 68
4.4
CHARACTERISTICS
OF
CONSTRUCTION ................................................................................ 68
4.5
POWER
SUPPLY ................................................................................................................................ 69
3
Product specificaties
Merk: | Gossen Metrawatt |
Categorie: | Multimeter |
Model: | METRACLIP 87 |
Heb je hulp nodig?
Als je hulp nodig hebt met Gossen Metrawatt METRACLIP 87 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter Gossen Metrawatt
19 Maart 2024
27 Februari 2024
27 Februari 2024
27 Februari 2024
27 Februari 2024
27 Februari 2024
27 Februari 2024
27 Februari 2024
9 Juli 2023
8 Juli 2023
Handleiding Multimeter
- Multimeter Abus
- Multimeter Aldi
- Multimeter Alecto
- Multimeter Altai
- Multimeter Amiko
- Multimeter Amprobe
- Multimeter Appa
- Multimeter Basetech
- Multimeter Beha-Amprobe
- Multimeter Benning
- Multimeter Brandson
- Multimeter Brennenstuhl
- Multimeter Bruder Mannesmann
- Multimeter Digitus
- Multimeter Elma
- Multimeter Elro
- Multimeter Extech
- Multimeter Ferm
- Multimeter Flir
- Multimeter Fluke
- Multimeter Gembird
- Multimeter Greenlee
- Multimeter Hager
- Multimeter Hubinont
- Multimeter Ideal
- Multimeter Keithley
- Multimeter Kingcraft
- Multimeter Laserliner
- Multimeter Mastech
- Multimeter Maxwell
- Multimeter Megger
- Multimeter Metrel
- Multimeter Metrix
- Multimeter Micronta
- Multimeter Milwaukee
- Multimeter Monacor
- Multimeter Parkside
- Multimeter PCE Instruments
- Multimeter Perel
- Multimeter Plieger
- Multimeter Powerfix
- Multimeter Profile
- Multimeter Sanwa
- Multimeter Schneider
- Multimeter Silverline
- Multimeter Skandia
- Multimeter Stanley
- Multimeter TFA
- Multimeter Topcraft
- Multimeter Uni-T
- Multimeter Velleman
- Multimeter Voltcraft
- Multimeter Wiha
- Multimeter Workzone
- Multimeter Joy-it
- Multimeter Jung
- Multimeter Clas Ohlson
- Multimeter Steren
- Multimeter Klein Tools
- Multimeter EMOS
- Multimeter Tacklife
- Multimeter Biltema
- Multimeter REV
- Multimeter Etekcity
- Multimeter Testo
- Multimeter Somogyi
- Multimeter Testboy
- Multimeter Yato
- Multimeter Wago
- Multimeter GW Instek
- Multimeter Kyoritsu
- Multimeter Owon
- Multimeter Projecta
- Multimeter Cablexpert
- Multimeter Högert
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Kewtech
- Multimeter Sonel
- Multimeter Testec
- Multimeter Vimar
- Multimeter Strex
- Multimeter PeakTech
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Rigol
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter IWH
- Multimeter Weltron
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nieuwste handleidingen voor Multimeter
21 December 2024
16 December 2024
7 December 2024
7 December 2024
5 December 2024
5 December 2024
3 December 2024
2 December 2024
1 December 2024
1 December 2024