Pagina 1/84
ge.com
Reverse Osmosis
101259 215C1174P004 49-50200 01-06 JR
Filtration System
PNRQ20FBL
PNRQ20FWW
PNRQ20FBB
PNRQ20FCC
Owner’s Manual
and Installation
Safety Instructions
Safety Instructions . . . . . . . . . . . . . .2
Specification Guidelines . . . . . . . . .3
Operating Instructions
About the RO System . . . . . . . . .4, 5
Installation Instructions
Tools and Materials Required . . . . .6
Before Beginning Installation . . .6, 7
Mounting System Installation . . . . .8
Feed Water Supply . . . . . . . . . . .9–12
Faucet Assembly . . . . . . . . . . . .13, 14
Battery Installation . . . . . . . . . . . .14
Filtration Drain Connection . .15, 16
Storage Tank and Startup . . . . . . .17
Care and Cleaning
Prefilter, Postfilter and
RO Cartridge Replacement . . . . . .18
Sanitization . . . . . . . . . . . . . . . . . .19
Water Test Kit . . . . . . . . . . . . . . . .20
Troubleshooting Tips . . . . . . .21–23
Consumer Support
Consumer Support . . . . .Back Cover
Parts List/Catalog . . . . . . . . . .24, 25
Warranty . . . . . . . . . . . . . . . . . . . .26
Manuel d’utilisation
et d’installation
Manual del propietario
y instalación
La section française commence à la page 27
Osmose Inversée
Système de Filtration
La sección en español empieza en la página 55
Ósmosis Inversa
Sistema de Filtración
Tested and Certified by NSF International to
NSF/ANSI Standard 58. For the reduction of the
claims specified, see the Performance Data Sheet.
Essayé et certifié par NSF International
conformément aux normes 58 NSF/ANSI. Pour
la réduction des caractéristiques indiquées,
consultez la feuille de données de rendement.
Probado y certificado por NSF International por
cumplir con el estándar 58. Para la reducción de
reclamos especificados, ver la hoja de datos de
desempeño.
Write the model and serial
numbers here:
Model # __________________
Serial # __________________
You can find them on the bracket.
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
■Check with your state and local public works
department for plumbing and sanitation codes.
You must follow these guidelines as you install the
Reverse Osmosis system. Using a qualified installer
is recommended.
■If house water pressure is over the maximum
(120 pounds per square inch), install a pressure
reducing valve in the water supply line to the
Reverse Osmosis system.
■
Be sure the water supply conforms with the
Specification Guidelines. If the water supply conditions
are unknown, contact your municipal water company
or your local health department for a list of
contaminants in your area and a list of laboratories
certified by your state to analyze drinking water.
WARNING: Before using the Reverse Osmosis
system for the first time, the system must be
purged. The Reverse Osmosis cartridge contains
a food grade preservative that must be purged
from the system. The preservative will give product
water an unpleasant taste and odor.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown quality
without adequate disinfection before or after the
system. Systems certified for cyst reduction may
be used on disinfected water that may contain
filterable cysts.
This system has been tested for the treatment of
water containing pentavalent arsenic (also known
as As(V), As(+5) or arsenate) at concentrations
of 0.050 mg/L or less. This system reduces
pentavalent arsenic, but may not remove other
forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine
residual or on water supplies that have been
demonstrated to contain only pentavalent arsenic.
Treatment with chloramine (combined chlorine)
is not sufficient to ensure complete conversion of
trivalent arsenic to pentavalent arsenic. Please see
the Arsenic Facts section of the Performance Data
Sheet for further information.
This reverse osmosis system contains a replaceable
component critical to efficiency of the system.
Replacement of the reverse osmosis component
should be with one of identical specifications, as
defined by the manufacturer, to assure the same
efficiency and contaminant reduction performance.
SAVE THESE INSTRUCTIONS
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
■Install or store where it will not be exposed to
temperatures below freezing or exposed to any type
of weather. Water freezing in the system will
damage it. Do not attempt to treat water over 100°F.
■Do not install on HOT WATER. The temperature
of the water supply to the Reverse Osmosis system
must be between the minimum of 40°F and the
maximum of 100°F. See the Specification Guidelines.
■Extended non-use of the Reverse Osmosis system.
If the system has not been used for one week or
more, open the RO water faucet and allow the
system to drain. Close the RO water faucet and
allow the system to regenerate the water supply.
■Recommended installation is under the sink.
However, the unit can be installed in a remote
location, up to 20 feet away from the sink.
• However, additional materials will be required,
including additional tubing and extension
phone cable. This extension phone cable
must be 6 conductor wire and connectors;
typical 4 conductor wire will not work. See parts
list to obtain additional materials from GE.
• Locating the tank on a basement floor, with the
faucet at a first floor sink may result in some loss
of flow rate and capacity (approximately 20%).
Installing a second tank will improve this
performance. An RVKIT can be used.
■If Reverse Osmosis system is connected to a
refrigerator icemaker, a special icemaker
connection kit is required (RVKIT). Do not use
copper tubing for the connection between the
Reverse Osmosis system and the refrigerator.
WARNING: Discard all unused parts and packaging
material after installation. Small parts remaining after
the installation could be a choke hazard.
■
Sanitize upon installation of the Reverse Osmosis
system and after servicing inner parts, including
replacement of prefilter, postfilter and Reverse
Osmosis cartridge. It is important to have clean
hands while handling inner parts of the system.
See the Sanitizing the Reverse Osmosis System section.
■
This Reverse Osmosis system contains a replaceable
treatment component critical for effective
reduction of total dissolved solids. This product
water shall be tested periodically to verify that the
system is performing satisfactorily. See the About
the Water Test Kit section.
BE SURE TO FOLLOW ALL APPLICABLE STATE
AND LOCAL CODES.
WARNING! For your safety, the information in this manual must be followed to minimize the risk of
property damage or personal injury.
SAFETY PRECAUTIONS
PROPER INSTALLATION AND MAINTENANCE
This Reverse Osmosis system must be properly installed and located in accordance with the
Installation
Instructions before it is used.
Consumer Support Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
2
Consumer SupportTroubleshooting TipsOperating Instructions
Safety Instructions
Installation Instructions
Specification guidelines.
ge.com
The system makes a good supply of drinking water each day.
How much it will make depends primarily on these things…
Product – height 11″width 10.5″depth 4″
Incoming Water pH
WATER SOFTENER RECOMMENDED
INCOMING WATER HARDNESS (GPG)
60
50
40
30
2010
8
6
7
7.5
6.5
Water Softener
not required
Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . . . .<0.1
Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0 ppm Maximum Allowable
b
Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10
Storage tank capacity—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
c
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes
Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROPF) Carbon Block
Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROMF) Thin Film Polyamide
Storage Tank Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height diameter 15” 11”
System Body Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height depth 11” 10.5”width 4”
Feed water pressure limits—pounds per square inch (psi) . . . . . . . . . . . . . . . . . . . . . .40–120
a
Feed water temperature limits—minimum/maximum degrees F . . . . . . . . . . . . . . . . .40–100
Maximum Total Dissolved Solids (TDS)—parts per million (ppm) . . . . . . . . . . . . . . . .2000
Maximum water hardness @ 6.9 pH recommended to optimize membrane
life—grains per gallon (gpg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
For water with hardness greater than 10 grains (at 6.9 pH), the use of a
softener is recommended. Failure to install a water softener will reduce
the life of the Reverse Osmosis membrane. See chart for additional
information on the possible need for a water softener.
a. If house water pressure is over 120 psi, install a pressure reducing valve in the water supply line. If house water pressure
is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing supply company).
b. Removed (maximum of 2.0 ppm) by the Reverse Osmosis prefilter. REGULAR MAINTENANCE IS REQUIRED. Chlorine will
destroy the Reverse Osmosis membrane.
c. Theoretical tank capacity. When tested according to NSF/ANSI Standard 58 at 50 psig inlet pressure, tank capacity is
2.3 gallons.
3
Product specificaties
Merk: | GE |
Categorie: | Waterfilter |
Model: | Profile PNRQ20FWW |
Heb je hulp nodig?
Als je hulp nodig hebt met GE Profile PNRQ20FWW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Waterfilter GE
16 April 2024
13 Juni 2023
23 April 2023
23 April 2023
21 April 2023
17 April 2023
12 April 2023
4 April 2023
23 Maart 2023
20 Maart 2023
Handleiding Waterfilter
- Waterfilter Electrolux
- Waterfilter Philips
- Waterfilter Panasonic
- Waterfilter LG
- Waterfilter JBL
- Waterfilter Tefal
- Waterfilter Zanussi
- Waterfilter Astralpool
- Waterfilter Avanti
- Waterfilter Bartscher
- Waterfilter Breville
- Waterfilter Brita
- Waterfilter BWT
- Waterfilter Eden
- Waterfilter Eheim
- Waterfilter Fisher And Paykel
- Waterfilter Franke
- Waterfilter Grohe
- Waterfilter Haier
- Waterfilter Kent
- Waterfilter Laica
- Waterfilter Midea
- Waterfilter Smeg
- Waterfilter Solac
- Waterfilter Sunbeam
- Waterfilter Terraillon
- Waterfilter Ufesa
- Waterfilter Verbatim
- Waterfilter Zodiac
- Waterfilter Jata
- Waterfilter Jura
- Waterfilter Juwel
- Waterfilter Oase
- Waterfilter Imetec
- Waterfilter Fluval
- Waterfilter Eldom
- Waterfilter Aarke
- Waterfilter Ecowater
- Waterfilter Flama
- Waterfilter FIAP
- Waterfilter Pureit
- Waterfilter Everpure
- Waterfilter Consul
- Waterfilter T.I.P.
- Waterfilter MSR
- Waterfilter JANDY
- Waterfilter Billi
- Waterfilter LifeStraw
- Waterfilter Baracuda
- Waterfilter Waterdrop
- Waterfilter Zip
- Waterfilter Waterco
- Waterfilter Aquasure
- Waterfilter ZeroWater
- Waterfilter Beemur
- Waterfilter Ionmax
- Waterfilter Puretec
- Waterfilter Tunze
- Waterfilter Aqua Medic
- Waterfilter PUR
- Waterfilter Sera
- Waterfilter Oliveri
- Waterfilter Hydor
- Waterfilter Heissner
- Waterfilter Aquael
- Waterfilter LARQ
- Waterfilter Platypus
Nieuwste handleidingen voor Waterfilter
18 December 2024
18 December 2024
18 December 2024
16 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024