JANDY CV460 Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor JANDY CV460 (32 pagina's) in de categorie Waterfilter. Deze handleiding was nuttig voor 3 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
Cartridge Pool Filters
Models: CL
CV VersaPlumb
Essential installation and startup instructions are included in this manual.
Additional operation and troubleshooting information is available online by
scanning the QR code with your phone or visiting jandy.com
WARNING
FOR YOUR SAFETY ā€“ This product must be installed and serviced by a contractor who is licensed and qualiļ¬ ed in pool
equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The
maintainer must be a professional with sufļ¬ cient experience in pool equipment installation and maintenance so that all of
the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and
instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage,
personal injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which may cause serious injury, property
damage, or death.
ATTENTION INSTALLER ā€“ This manual contains important information about the in stal la tion, operation and
safe use of this product. Thisī˜žinformation should be given to the owner/operator of this equipment.
Installation and Operation Manual
Manuel dā€™installation et dā€™utilisation
Manual de instalaciĆ³n y operaciĆ³n
Page 2
ENGLISH Jandy
Ā®
Cartridge Pool Filters | Installation & Operation Manual
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAR FILTER)
PUMP MODEL HORSEPOWER
FILTER MODEL SERIAL NUMBER
NOTES:
Table of Contents
Section 1. Important Safety Instructions 3 ....
1.1 Important Safety Warning 3 .........................
1.2 General Safety Instructions 3 ......................
Section 2. General Information 4 ....................
2.1 Introduction............................................... 4
2.2 Description ................................................ 4
2.3 General Requirements 4 ..............................
2.4 Speciļ¬cations and Dimensions 4 ................
Section 3. Installation Instructions 5 ..............
3.1 Filter Location 5 ...........................................
3.2 Anchor Bracket Installation 5 .......................
3.3 Filter Preparation 5 ......................................
3.4 Filter Plumbing 6 ..........................................
3.5 Clamp Installation 9 .....................................
Section 4. Start-Up and Operation 9 ..............
Section 5. Filter Disassembly
and Assembly 10 ............................
Section 6. Maintenance 11 ..............................
6.1 General Maintenance 11 ..............................
6.2 Pressure Gauge 11 ......................................
6.3 Cleaning the Filter Cartridge 11 ...................
Section 7. Winterizing 11 .................................
Section 8. Troubleshooting 12 ........................
Section 9. Parts List and Exploded View 13 ..
9.1 Jandy Pro CL and CV Cartridge
Filter Parts List 13 .......................................
9.2 Jandy Pro CL and CV Filters
Exploded View 14 .......................................
Section 10. Head Loss Curves 15 ...................
10.1 Jandy Pro CL and CV Cartridge
Filter Design Head Loss Curves 15 .............
Jandy
Ā®
Cartridge Pool Filters | Installation & Operation Manual ENGLISH
Page 3
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Important Safety Warning
WARNING
ā€¢ Do not connect system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
ā€¢ Pressurized air in system can cause product failure or also cause the ļ¬lter lid to be blown off which
can result in death, serious personal injury, or property damage. Be sure all air is out of system before
operating or testing the equipment.
MAXIMUM OPERATING PRESSURE OF THE FILTER IS 50 PSI. NEVER SUBJECT THE FILTER TO ANY
OPERATING PRESSURE EXCEEDING 50 PSI.
This ļ¬lter operates under high pressure. When any part of the circulating system, i.e., ļ¬lter, pump, valve(s), clamp,
etc. is serviced, air can enter the system and become pressurized when the system is restarted. Pressurized air
can cause product failure or also cause the ļ¬lter lid to be blown off which can result in death, serious personal
injury or property damage. To avoid this potential hazard, follow all of the instructions in this manual.
To minimize risk of severe injury or death the ļ¬lter and/or pump should not be subjected to the piping system
pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements are
generally not intended to apply to the pool equipment such as ļ¬lters or pumps.
Jandy Pro Series pool equipment is pressure tested at the factory.
If however this WARNING cannot be followed and pressure testing of the piping system must include the ļ¬lter
and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
ā€¢ Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and
secured before testing.
ā€¢ in the system before testing.RELEASE ALL AIR
ā€¢ Water pressure for test must NOT EXCEED 35 PSI.
ā€¢ Water temperature for test must NOT EXCEED 100Ā°F (38Ā°C).
ā€¢ Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy Pro Series equipment only. For non-Jandy equipment, consult equipment manufacturer.
1.2 General Safety Instructions
ATTENTION INSTALLER
This manual contains important information about the installation, operation and safe use of this product.
This information should be given to the owner/operator of this equipment.
1. Use equipment only in a pool or spa installation.
2. Before repositioning valve(s) and before beginning
the assembly, disassembly, or adjustment of the
clamp, or any other service of the circulating system;
(A) and shut off any automatic turn the pump off
controls to ensure the system is not inadvertently
started during servicing; (B) open the air release
valve; (C) wait until all pressure is relieved (air will
have stopped ļ¬‚owing from the air release valve).
3. Whenever installing the ļ¬lter clamp follow Section
3.5 ā€œClamp Installationā€ of this manual, .
4. Once service on the circulation system is complete,
follow Section 4 ā€œStart-up and of this manual,
Operationā€.
5. Maintain circulation system properly. Replace worn
or damaged parts immediately.
6. Be sure that the ļ¬lter is properly mounted
and positioned according to these installation
instructions.
7. Do not pressure test above 35 PSI. Pressure testing
must be done by a trained pool professional.
SAVE THESE INSTRUCTIONS


Product specificaties

Merk: JANDY
Categorie: Waterfilter
Model: CV460

Heb je hulp nodig?

Als je hulp nodig hebt met JANDY CV460 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Waterfilter JANDY

JANDY

JANDY CV460 Handleiding

29 Maart 2025
JANDY

JANDY CS250 Handleiding

18 December 2024
JANDY

JANDY CS150 Handleiding

18 December 2024
JANDY

JANDY CS100 Handleiding

18 December 2024

Handleiding Waterfilter

Nieuwste handleidingen voor Waterfilter