Pagina 1/4
REQUIRED TOOLS FOR INSTALLATION
β 2 wrenches: 1 1β and8β³
11
β
4
β³
β Pipe cutter or hack saw
β File
CONTENTS INCLUDED WITH PRODUCT
β Filter housing and head
β Sediment filter
β
(2)
3β4β³
brass compression fittings with nut
and ferrule
β
Teflon tape
β Product literature
β
Sump wrench
β
Grounding clamps and wire
1
GE SmartWater β’
INSTALLATION INSTRUCTIONS
Household Water Filtration System β GNWH08C
251B6021P004 49-500638-00 JR
www.geappliances.com
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
SAFETY PRECAUTIONS
β
Check with your state and local public works
department for plumbing and sanitation codes.
You must follow these guidelines as you install
the Household Water Filtration System. Using
a qualified installer is recommended.
β
Be sure the water supply conforms with the
Specifications
guidelines
. If the water supply conditions are unknown,
contact your municipal water company
.
WARNING:
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system.
β
I
t is highly recommended that a water shut off valve
be placed directly upstream of your household filter.
PROPER INSTALLATION
β
Check with your local public works department for plumbing
codes. You must follow their guides as you install the
Household Filtration System.
β
Use the Household Filtration System on a potable, safe-to-
drink, home COLD water supply only. The filter cartridge will
not purify water or make unsafe water safe to drink. DO NOT
use on HOT water (100ΛF. max).
β
Protect the Household Filtration System and piping from
freezing. Water freezing in the system will damage it.
β
Your Household Filtration System will withstand up to 125 psi
water pressure. If your house water supply pressure is
higher than 100 psi during the day (it may reach higher levels
at night), install a pressure reducing valve before the system
is installed.
β
Do not install on
HOT WATER
. The temperature of the
water supply to the Household Filtration System must
be between the minimum of 40
Β°F. and the maximum
of
1
00Β°F
. See the
Specification guidelines
.
β
Do not
install the Household Filtration System using
copper solder fittings. The heat from the soldering
process will damage the unit.
WARNING:
Discard all unused parts and packaging
material after installation. Small parts remaining after
installation could be a choke hazard.
β
Do not
install filter in an outside location or anywhere
it will be exposed to sunlight.
This Household Filtration System must be properly installed and located in accordance with the Installation Instructions before it is used.
System is
Tested and Certified by NSF
International against ANSI/NSF
Standard 42
for Particulate Reduction Class . III
GNWH08C
2
ABOUT THE FILTER CARTRIDGE
Filter Cartridge Replacement
You should change your filter when the water flow is noticeably reduced or at least every three months.
Filter Cartridge Life
Several variables determine how long the
cartridge will last in your Household
Water Filtration System. These include:
β
levels of sediment or other undesirable
substances in your water.
β
the amount of water you use.
β
the filter location (filtering all or part of
household water).
GE MODEL FUNCTION LIFE CONSTRUCTION
FXUSC* Sediment 3 month/16,000 gallons Polyspun
5 Micron
FXWPC Sediment 3 month/16,000 gallons Pleated
30 Micron
FXWSC Sediment 3 month/16,000 gallons String Wound
10 Micron
FXWTC* Sediment 3 month/15,000 gallons Carbon Paper
10 Micron
Chlorine
*NSF Certification for particulate reduction applies only to the FXUSC and FXWTC when
used in GNWH08C.
Turn off water to filter by rotating the by-pass
valve to the by-pass position.
Press the red pressure release button to release
pressure.
Unscrew the filter canister and discard used
filter. Wash the filter canister with mild soap
and water.
Do not
use harsh cleaners or hot
water.
Inspect the filter canister O-ring. Make sure it
is lightly lubricated and completely seated in
the groove. It is recommended that you
replace the O-ring if it is damaged.
Place a new filter cartridge into the canister
making sure it is centered and completely
seated on the bottom seal.
Reinstall the filter canister to the unit. Hand
tightening is all that is required to seal the unit.
Slowly turn on water to the filter by using the
by-pass valve.
Press the red pressure release button to
remove trapped air.
Open any downstream faucet and allow filter
system to flush for 5 minutes.
9
8
7
6
5
4
3
2
1
Installation Overview
NOTE: Be sure to allow a minimum space of 1
1
β
2
β³
under the filter for removing the sump, to change
the cartridge.
Turn sump wrench tool
clockwise to remove
Sump
By-pass valve
Filter
cartridge O-ring seal
Red pressure
release button
Head
Filter canister
Turn
clockwise
to remove
canister
Turn
counterclockwise
to tighten
GNWH08C
Recommended
shut-off valve
GNWH08C
Specification Guidelines
MinimumβMaximum Supply Water Pressure: 20β125 pounds per square inch (psi)
MinimumβMaximum Supply Water Temperature: 40Β°F / 100Β°F Rated Service Flow: 4 gpm
Recommended
shut-off valve
STEP-BY-STEP INSTALLATION INSTRUCTIONS
3
STEP-BY-STEP INSTALLATION INSTRUCTIONS (cont.)
Select Location
Select a location for the filter that is:
β
protected from freezing.
β
not exposed to direct sunlight.
It is recommended that a shut-off valve be placed on both sides
of the filter.
Install Fittings
The fittings supplied with the filter are for use with 3β copper4β³
tubing only. If the unit is to be installed on any other type of
tubing (plastic, PVC, galvanized), separate hardware must
be purchased.
Apply about 6 of Teflon tape, in a clockwise direction, β³
to the pipe threads (course) of each adapter.
DO NOT
use
joint compound on any parts.
Assemble a fitting to the inlet and outlet of the head. Start
each fitting by hand to make sure they donβt cross thread.
Use a 11β8β³wrench firmly.
DO NOT OVERTIGHTEN.
About one
to two thread(s) should remain visible.
Cut Water Line
Turn off water supply and open a nearby faucet to drain
water out of pipes.
Remove the nut and brass ferrule from both compression
fittings and set aside. Using a tape measure or ruler,
measure the distance βDβ as shown.
β
NOTE:
I
t is recommended that the shut-off valve be placed
before and after the filter as shown in the
Installation
Overview
illustration.
β Select the location for the filter. Mark the distance βDβ
on the pipe.
Using a pipe cutter or hacksaw, cut pipe. Sand (file) cut
ends of pipe to assure that they are square and smooth.
3
2
1
Attach Fittings to Water Line
Slip a compression nut onto each pipe.
Next, slip the brass ferrule onto each pipe.
2
1
nut
brass ferrule
nut
brass ferrule
Measure to shoulder
of fittings. Copper
pipe butts against
this shoulder.
D
GNWH08C
Installing the Unit
Align filter assembly with pipe ends making certain that
the
incoming
water supply is going into the filter opening
marked βINβ. It may be necessary to spread the pipe ends
apart to install filter assembly.
Using a
11β8β³
wrench to hold the adapter in place, use a 11β4
β³
wrench to tighten the nut. Repeat process for other fittings.
If necessary, support the water pipe on either side of the
filter unit.
Installing the Ground Wire
IMPORTANT:
The house cold water pipe is often used to ground
electrical outlets in the home.
Grounding protects you from
electrical shock.
The water filter housing may have broken this
ground. To restore copper, buy and install a #6 copper wire
across the filter, tightly clamped at both ends as shown here.
Install clamps to copper pipe on both sides of the unit
(as shown).
Securely attach each end of the grounding wire to the pipe
with the clamps.
2
1
3
2
1
clamp
Final Check
Slowly turn on water supply.
Check entire system for leaks.
If leaking, shut off water pressure and tighten or reseal
fittings.
Open any downstream faucet and allow filter system to
flush for 5 minutes.
4
3
2
1
D
ground wire
Teflon tape
Product specificaties
Merk: | GE |
Categorie: | Waterfilter |
Model: | GNWH08C |
Heb je hulp nodig?
Als je hulp nodig hebt met GE GNWH08C stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Waterfilter GE
16 April 2024
13 Juni 2023
23 April 2023
23 April 2023
21 April 2023
17 April 2023
12 April 2023
4 April 2023
23 Maart 2023
20 Maart 2023
Handleiding Waterfilter
- Waterfilter Electrolux
- Waterfilter Philips
- Waterfilter Panasonic
- Waterfilter LG
- Waterfilter JBL
- Waterfilter Tefal
- Waterfilter Zanussi
- Waterfilter Astralpool
- Waterfilter Avanti
- Waterfilter Bartscher
- Waterfilter Breville
- Waterfilter Brita
- Waterfilter BWT
- Waterfilter Eden
- Waterfilter Eheim
- Waterfilter Fisher And Paykel
- Waterfilter Franke
- Waterfilter Grohe
- Waterfilter Haier
- Waterfilter Kent
- Waterfilter Laica
- Waterfilter Midea
- Waterfilter Smeg
- Waterfilter Solac
- Waterfilter Sunbeam
- Waterfilter Terraillon
- Waterfilter Ufesa
- Waterfilter Verbatim
- Waterfilter Zodiac
- Waterfilter Jata
- Waterfilter Jura
- Waterfilter Juwel
- Waterfilter Oase
- Waterfilter Imetec
- Waterfilter Fluval
- Waterfilter Eldom
- Waterfilter Aarke
- Waterfilter Ecowater
- Waterfilter Flama
- Waterfilter FIAP
- Waterfilter Pureit
- Waterfilter Everpure
- Waterfilter Consul
- Waterfilter T.I.P.
- Waterfilter MSR
- Waterfilter JANDY
- Waterfilter Billi
- Waterfilter LifeStraw
- Waterfilter Baracuda
- Waterfilter Waterdrop
- Waterfilter Zip
- Waterfilter Waterco
- Waterfilter Aquasure
- Waterfilter ZeroWater
- Waterfilter Beemur
- Waterfilter Ionmax
- Waterfilter Puretec
- Waterfilter Tunze
- Waterfilter Aqua Medic
- Waterfilter PUR
- Waterfilter Sera
- Waterfilter Oliveri
- Waterfilter Hydor
- Waterfilter Heissner
- Waterfilter Aquael
- Waterfilter LARQ
- Waterfilter Platypus
Nieuwste handleidingen voor Waterfilter
18 December 2024
18 December 2024
18 December 2024
16 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024
10 December 2024