Fluke T130 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fluke T130 (3 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
T90/T110VDE/
T130VDE/T150VDE
Voltage/Continuity Tester
Instruction Sheet
Introduction
The Fluke T90/T110VDE/T130VDE/T150VDE
Electrical Testers (the Tester or Product) are
voltage and continuity testers with a rotary eld
indication (T110VDE/T130VDE/T150VDE only).
Their primary use is for test and measurement in
industrial, commercial, and household environments.
This Product complies with the most recent safety
standards for safe, reliable test and measurement.
The xed test probe cover prevents the risk of injury
when you move the instrument.
To Contact Fluke
Fluke Corporation operates worldwide. For local
contact information, go to our website: www.uke.com
To register your product, view, print, or download
the latest manual or manual supplement, go to our
website.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
+1-425-446-5500
uke-info@uke.com
Safety Information
 Warning
To prevent possible electrical shock, re, or
personal injury:
Read all safety Information before you use the
Product.
Use the Product only as specied, or the
protection supplied by the Product can be
compromised.
Measure a known voltage rst to make sure
that the Product operates correctly.
Do not apply more than the rated voltage,
between the terminals or between each
terminal and earth ground.
PN 3928126
October 2011, Rev. 3, 3/21
© 2011-2021 Fluke Corporation. All rights reserved.
Specications are subject to change without notice. All product
names are trademarks of their respective companies.
Limit operation to the specied measurement
category or voltage ratings.
Do not work alone.
Comply with local and national safety codes.
Use personal protective equipment (approved
rubber gloves, face protection, and ame-
resistant clothes) to prevent shock and arc
blast injury where hazardous live conductors
are exposed.
Do not use the Product around explosive gas,
vapor, or in damp or wet environments.
Do not use and disable the Product if it is
damaged.
Do not use the Product if it operates
incorrectly.
Keep ngers behind the nger guards on the
probes.
Do not use the Product if the test leads are
damaged.
Examine the case before you use the Product.
Look for cracks or missing plastic.
The battery door must be closed and fastened
before you operate the Product.
Replace the batteries when the low battery
indicator shows to prevent incorrect
measurements.
Repair the Product before use if the battery
leaks.
For use by competent persons. Anyone
using this Product should be knowledgeable
and trained about the risks involved with
measuring voltage, especially in an industrial
setting, and the importance of taking safety
precautions and of testing the Product before
and after using it to ensure that it is in good
working condition.
Symbols
These symbols are on the Tester or in this instruction
sheet.
Symbol Explanation
Important information. Consult the
instruction sheet.
Hazardous Voltage.
¥Suitable for live working.
This product complies with the WEEE
Directive (2002/96/EC) marking
requirements. The a󰀩xed label indicates
that you must not discard this electrical/
electronic product in domestic household
waste. Product Category: With reference
to the equipment types in the WEEE
Directive Annex I, this product is classed
as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose
of this product as unsorted municipal
waste. Go to Fluke’s website for recycling
information.
Symbol Explanation
Conforms to European Union Directives.
§VDE Association for Electrical, Electronic
& Information Technologies; following
rules of "Geprüfte Sicherheit."
CAT III Measurement Category III is applicable to
test and measuring circuits connected to
the distribution part of the building’s low-
voltage MAINS installation.
CAT IV Measurement Category IV is applicable
to test and measuring circuits connected
at the source of the building’s low-voltage
MAINS installation.
Accessories
The Tester is supplied with accessories.
Part Number Accessory
4083642 GS38 Probe Tip Sheath
4083656 4.2 mm Probe Extensions
4111533 H15 Belt Holster (sold separately)
4111540 C150 Zippered Soft Carrying Case
(sold separately)
Figure 1 shows the Probe Tip Protector Cap. This
multifunctional accessory is useful for tests and
storage of di󰀨erent accessories. (The Probe
Extensions are stored in the Probe Tip Protector Cap
before shipment.)
Storage area for Probe Tip Sheaths
Storage area for 4.2 mm Probe Extensions
Earth-pin safety-socket opener for UK
sockets (press opener into socket to release
safety covers, see Figure 2)
Storage area for probes when not in use
1
4
3
1
2
Quick Reference
Use the pushbuttons to turn the functions on or o󰀨.
See the list that follows for a quick reference to each
of these pushbuttons.
Pushbutton Description
c
Push to turn torch light on or o󰀨
(T110VDE, T130VDE, T150VDE).
To save battery power the
function automatically turns o󰀨
after 30 seconds.
I
Push to hold the value that shows
in the LCD in volt and resistance
measurements. Push again
to turn HOLD o󰀨 (T130VDE,
T150VDE).
To save battery power the
function automatically turns o󰀨
after 30 seconds.
h
Push this button on each of
the probes at the same time to
start the test for low impedance
switchable load.
Il
Push and hold for 2 seconds to
turn the resistance measurement
on or o󰀨 (T150VDE only).
To save battery power, the
function automatically turns o󰀨
after 30 seconds.
Figure 3 illustrates how to store and retrieve the tip
accessories from the cap.
For storage, push Probe Tip Sheath into
place.
To retrieve, rmly push probe tip into Probe
Tip Sheath.
Pull on probe handle to remove Probe Tip
Sheath.
For storage, push 4.2 mm Probe
Extensions into place.
To retrieve, rmly push probe tip into Probe
Extensions. Twist 1/4 turn.
Pull on probe handle to remove Probe
Extensions. Continue to twist until tip is tight.
3
1
4
2
5
1/4
3
6
2
Features
Model
T90 T110VDE T130VDE T150VDE
Complies with EN 61243-3:2014 • •
LED Indication Range: 12 V to 690 V dc and ac • •
V Display: Multiple LED Bargraph • •
Independent ELV indicator LED, indicates if >50 V ac/120 V dc is
present even in the event of no battery power or main circuit failure • •
LCD Indication Range: 6 V to 690 V dc and ac • •
V Display: Digital LCD 3½ digit (1 V resolution) • •
Resistance Measurement: LCD 3½ digit (0 to 1999 Ω/1Ω resolution)
LCD Backlight • •
Display HOLD: Freeze/unfreeze display with voltage or resistance
measurement • •
CAT II 690 V / CAT III 600 V
CAT III 690 V / CAT IV 600 V • •
Rugged, Double-Insulated Wire • •
Fixed Impedance ~200 kΩ ( 3.5 mA @ 690 V)• •
Switchable Load by 2 pushbuttons (~30 mA @ 230 V) • •
Vibration During Load (when 2 switchable load pushbuttons are
pushed)
• •
Single-Pole Phase Test (also operates with gloves) • •
Rotary Field Direction (also operates with gloves) • •
Continuity Test / Diode Test • •
Torch • •
Beeper for Continuity/Phase/ACV • •
IP54
IP64 • •
Slim Metal Probe Tips (threaded base for included tip accessories) • •
Probe Tip Protector Cap (secure storage for the docked probes) • •
4.2 mm Probe Tip Thickness Extensions (for better t in outlets) • •
19 mm Probe Tip distance when docked • •
Probe Tip Sheath (UK GS38 sheath–keeps the exposed metal to a
<4 mm limit) • •
Slim Probe for Ultra-Compact Form Factor
Display
LEDs
(All Models) Description
y
x
w
v
u
t
s
Voltage level is backlit
zVoltage level is more than ELV
limit (>50 V ac or >120 V dc)
aVoltage is ac / phase in Single
Pole Phase test
d
DC
e
Voltage is positive or negative at
the indicator probe
bBattery is low / Replace battery
fContinuity or diode in forward
operation
gSwitchable load is ON (two buttons
pressed and current ows)
q r 3-phase sequence indication
detected left or right turning
phases with nonindicator probe
(L1) to indicator probe (L2)
1
3
2
4
5
6
gpn76.eps
LCD
(T130VDE/
T150VDE)
Description
Display is in HOLD mode
Voltage measurement (T130VDE/
T150VDE) or resistance
measurement (T150VDE)
Resistance measurement
(T150VDE)
AC Voltage measurement
DC Voltage measurement
Battery is low / Replace battery
How to Hold the Tester
Always hold the product behind the barrier to keep the
display in view. See Figure 4.
 Warning
To prevent possible electric shock, never
touch the metal pins of the probes when
power is applied.
Self‑Test
The Tester has a built-in self test function.
Before and after use, do a self-test:
1. Touch and hold the probe tips together.
f shows and you can hear the beeper. This
makes sure that the test leads have continuity.
2. Make sure that:
batteries are good
b (T90, T110VDE) is NOT on
(T130VDE VDE) does not show in B , T150
the display
3. Continue to hold the probe tips together for more
than three seconds.
4. Open the probe tips again. All LEDs (all but z
and ) must be on and all symbols in the LCD g
(T130VDE, T150VDE) show for one second. This
test makes sure that all other internal circuits and
indicators are good.
5. Measure a known voltage such as a 230 V socket
outlet. This completes the self-test and includes
the >ELV circuit.
If the Tester fails the self-test or voltage test, do not
use. See To Contact Fluke for servicing.
For an inspection of the insulation, cables, and case,
see .Safety Information
4 5
Environmental
Pollution degree 2 .......................
Protection degree IP54 (T90) .....................
IP64 (T110VDE/
T130VDE/
T150VDE)
Operating Temperature ............-15 °C to +45 °C
Storage Temperature ................-20 °C to +60 °C
Humidity ...................................85 % RH maximum
Altitude 2000 m .....................................
Vibration refer to EN61243-3 ...................................
Safety EN61243-3:2014
Agency approvals VDE-GS .....................
Transporting goods...................VBG 1, § 35
Overvoltage protection 690 V ac/dc .............
Measurement category
T90......................................CAT II 690 V
CAT III 600 V
T110VDE/T130VDE/
T150VDE CAT III 690 V ............................
CAT IV 600 V
Power supply ...............................2 x 1.5 V Micro /
LR03 / AAA
Power consumption ....................50 mA maximum /
~250 mW
Language support .......................German, English,
French, Italian
LIMITED WARRANTY & LIMITATION OF
LIABILITY
This Fluke product will be free from defects in material and
workmanship for two years from the date of purchase. This
warranty does not cover fuses, disposable batteries, or damage
from accident, neglect, misuse, alteration, contamination, or
abnormal conditions of operation or handling. Resellers are not
authorized to extend any other warranty on Fluke’s behalf. To
obtain service during the warranty period, contact your nearest
Fluke authorized service center to obtain return authorization
information, then send your defective Tester to that Service
Center with a description of the problem. Replace depleted
batteries immediately to avoid Tester damage from battery
leakage.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM
ANY CAUSE OR THEORY. Since some states or countries do
not allow the exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of liability
may not apply to you.
Fluke Corporation Fluke Europe B.V
P.O. Box 9090 P.O. Box 1186
Everett WA 98206-9090 5602 B.D.
Eindhoven
The Netherlands
11/99
Specications
Model
T90 T110VDE T130VDE T150VDE
LEDs
Voltage range 12 V to 690 V ac/dc • •
Resolution ±12 V, 24 V, 50 V, 120 V, 230 V,
400 V, 690 V • •
Tolerance Complies with
EN 61243-3:2014 • •
Frequency range 0 / 40 Hz to 400 Hz • •
Response time 0.5 second • •
Auto power on 12V ac/dc • •
LCD
Voltage range 6 V to 690 V ac/dc • •
Resolution 1 V±• •
Tolerance (3 % rdg + 5 digits)±• •
Frequency range 0 / 40 Hz to 400 Hz • •
Response time 1 second• •
Auto power on 6 V ac/dc• •
Voltage detection Automatic • •
Polarity detection Full range • •
Range detection Automatic • •
Internal basic load
impedance Peak current
Maximum 3.5 mA at 690 V
200 k / Is <3.5 mA (no RCD Ω
tripping) • •
Operation time Duration Time = 30 seconds • •
Recovery time Recovery Time = 240 seconds • •
Switchable Load ~7 kΩ • •
Peak current Is (load) = 150 mA • •
RCD tripping I ~30mA @ 230V • •
Continuity Test 0 to 400 kΩ • •
Accuracy nominal resistance +50 % • •
Test current 5 A≤ µ • •
Single-pole Phase Test 100 V ac to 690 V ac • •
Frequency range 40 Hz to 60 Hz
50 Hz to 400 Hz • •
Rotary Field Indication • •
Voltage range (LEDs) 100 V to 690 V
(phase to earth) • •
Frequency range 50 Hz to 60 Hz • •
Resistance Measurement 0 to 1999 Ω Ω
Resolution 1 Ω
Tolerance ±(5 % rdg +10 digits) @ 20 °C
Temperature coe󰀩cient ±5 digits / 10 K
Test current 30 A≤ µ
Size in mm (HxWxL) 245x64x28 255x78x35
Weight in kg (includes batteries) 0.18 0.27
How to Clean
Before you clean the Tester, remove it from all
measurement circuits.
Caution
To prevent damage, do not use abrasives or
solvents on the Tester.
Clean the case with a moist cloth and weak detergent.
After you clean the Tester, do not use it for a period
of 5 hours.
When to Calibrate
Fluke recommends a calibration interval of 1 year.
Battery Replacement
If (Fluke T90/T110VDE) is on or shows in bB
the LCD (Fluke T130VDE/T150VDE) during tests or
measurements, replace the batteries.
To replace the batteries:
1. Disconnect the Tester from the measurement
circuit.
2. Open the battery cover. See Figure 8.
3. Remove the discharged batteries.
4. Replace with two new 1.5V IEC LR03 AAA
batteries.
5. Align the battery polarity as shown on the case
housing.
6. Close and attach the battery cover.
Note
Do not overtighten the screw for the battery cover.
7. Complete a self-test.
8


Product specificaties

Merk: Fluke
Categorie: Meetapparatuur
Model: T130
Gewicht: 280 g
Breedte: 70 mm
Diepte: 38 mm
Hoogte: 260 mm
Kleur behuizing: Black, Grey, Red, Yellow
DC voltage bereik: - V
Type batterij: AAA
AC voltage bereik: - V
AC stroom bereik: - A
Maximaal voltage: - V

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke T130 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Fluke

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur