Fluke 1507 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fluke 1507 (33 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 343 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/33
150X Series
Insulation Testers
Calibration Manual
November 2005 Rev. 2, 11/21 (English)
©2005 - 2021 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under normal use
and service. The warranty period is 1 year and begins on the date of shipment. Parts, product repairs, and
services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer
of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which,
in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or
abnormal conditions of operation or handling. Fluke wa substantially in rrants that software will operate
accordance with its functional specifications for 90 days and that it has been properly recorded on non-
defective media. Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers
only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is
available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/
replacement parts when product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge
repair, or replacement of a defective product which is returned to a Fluke authorized service center within
the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that service center, with a description of the difficulty,
postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal
condition of operation or handling, including overvoltage failures caused by use outside the product’s
specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of
repair costs and obtain authorizat product will be ion before commencing the work. Following repair, the
returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return
transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF
DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any
other provision.
11/99
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
i
Table of Contents
Introduction................................................................................................................................... 1
Safety Information...................................................................................................................... 2
Contact Fluke ............................................................................................................................... 3
General Specifications.............................................................................................................. 3
Basic Maintenance ..................................................................................................................... 3
Clean the Product .............................................................................................................. 3
Test the Batteries............................................................................................................... 4
Replace the Batteries and/or Fuse.............................................................................. 4
Test the Display .................................................................................................................. 5
Backlight Test...................................................................................................................... 5
Keypad Test ......................................................................................................................... 6
Disassemble and Reassemble the Tester ................................................................ 6
Remove the Holster........................................................................................................... 7
Remove the Battery Door ............................................................................................... 7
Open the Bottom Case ............................................................................................................. 8
Remove the PCA ......................................................................................................................... 8
Remove the Display .......................................................................................................... 10
Replacing the LCD ............................................................................................................. 11
Reassemble the Tester.................................................................................................... 11
Required Tools and Equipment .................................................................................... 12
Performance Tests..................................................................................................................... 13
Test the Voltage Function .............................................................................................. 13
Discharge Circuit Test...................................................................................................... 14
Test the Insulation Function........................................................................................... 14
Insulation Resistance Accuracy Tests.............................................................. 15
Insulation Function, External Sense................................................................... 16
Source Voltage Accuracy Test, "R" Nominal................................................... 16
Source Voltage Accuracy Test, Open Circuit ................................................ 17
I Nominal Test ............................................................................................................. 18
I Limit Test.................................................................................................................... 18
Test the Ohm Function............................................................................................ 19
2-Ohm Output Current Test.................................................................................. 20
Open Circuit Voltage Test...................................................................................... 20
Calibration Adjustment............................................................................................................. 20
Calibration Adjustment Counter................................................................................... 20
Calibration Adjustment Password ............................................................................... 21
Change the Password ............................................................................................. 21
Restore the Default Password ............................................................................. 21


Product specificaties

Merk: Fluke
Categorie: Meetapparatuur
Model: 1507
Gewicht: 550 g
Breedte: 100 mm
Diepte: 50 mm
Hoogte: 203 mm
Internationale veiligheidscode (IP): IP40
Kleur behuizing: Grey, Yellow
Ondersteund aantal accu's/batterijen: 4
Temperatuur bij opslag: -40 - 60 °C
Hoogte, in bedrijf: 0 - 2000 m
Hoogte bij opslag: 0 - 12000 m
Overbelastingsprotectie: Ja
Trillingen, in bedrijf: 2 G
Bedrijfstemperatuur (T-T): -20 - 55 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Synchronisatie ingangsimpedantie: 3000000 Ohm
Batterijformaat: AA
Maximaal voltage: 600 V
Valbestendig tot: 1 m
Maximale capacitieve last: 1 µF
Isolatiemeetnauwkeurigheid (500 V): 1.5 procent
Isolatiemeetnauwkeurigheid (1000 V): 1.5 procent
Automatische ontladingstijd: 0.5 s
Isolatietestspanningsnauwkeurigheid: 20 procent
Isolatiemeetnauwkeurigheid: 0.01 - 2000 MΩ
Isolatiemeetnauwkeurigheid (50 V): 3 procent
Isolatiemeetnauwkeurigheid (100 V): 3 procent
Isolatiemeetnauwkeurigheid (250 V): 1.5 procent

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke 1507 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Fluke

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur