See overleaf for further setting up information
Sensor selection. This thermostat is a combination model allowing you to choose
between 4 different models. (A, AF,F )
A model: air only, with built in sensor
AF model: air & floo r , with both built in and remote sensor
F model: floor only, with remote sensor
Configuration Menu
Turning ON/OFF Your Thermostat
Press buttton to turn the thermostat ON or OFF. When thermostat is turned off, LCD will display OFF.
This thermostat is full of useful features which can be set quite easily through the feature configuration menu. To access the feature configuration menu, simply turn off your thermostat
and hold button M for 5 seconds. Now you can see Menu 1, to proeceed to other menu, press button M again. To exit menu, press button
Menu #
1
Switching differential.
Calibrate the room temperature. This feature is used to compensate for any difference
Calibrate the floor temperature. This feature is used to compensate for any difference
Set the floor temperature limit.
Set backlight turning-on time. Selecting on will turn the light on continuously.
Selecting off will turn the light off. Selecting 20 seconds will turn the light on for 20 seconds.
Select temperature format
Optimum start(preheat). This feature is to ensure that the required temperature has
already been reached when you get up in the morning or come home from work.
Select 12 / 24 hour clock
24 12 / 24
Pump protection(for hydronic heating only). In hydronic heating installations, it is
recommended to activate the pump at least 15 seconds every 24 hours in order to
avoid any seizing. Select ON to activate this feature, OFF to deactivate. When the
thermostat is activating the pump, the icon will blink.
2
3
4
5
6
7
8
9
10
11
12
Feature Description Factory Default
Feature Value
0
°C
OFF ON / OFF
ON / OFF
OFF
7_0 5_2 / 6_1 / 7_0
OFF ON / OFF
40
°C
20
°C ~
40
°C
20 seconds 20 seconds / ON /OFF
°C
/
°F
°C
A / AF / F A
Press or to select
This product should be installed by a qualified electrician.
The number of degrees difference between switching off at the
between the displayed room temperature and a thermometer.
between the displayed floor temperature and a thermometer.
This feature is to protect the floor surface.
°C or °F.
Buttons and LCD display
Buttons
Short press
Press > 5 seconds
Turning on/off thermostat
Menu button( when thermostat is turned off)
Auto/Manual mode selection
Increase the set value Bring up vacation mode
Check floor temperature (AF model only)
Decrease the set value
Lock /unlock buttons
Reset to factory settings
(when thermostat is turned off)
+
+
Set the time and week days
Cancel override( when in override mode)
Confirm settings
M
M
The buttons are locked.
Displays when heating is active
Symbol Description
Auto mode(use button M to select)
Manual mode(use button M to select)
Vacation mode
Temporary temperature override
Frost protection activated
Set temperature
The program number
Program 1,2,
3,4,5,6
AUTO
SET AT
Program type selection.
This gives user 3 options of program type.
5_2 will give you 5 days(Monday to Fiday) with the same six events(Wakeup, out, home,
6_1 will give you 6 days(Monday to Saturday) with the same six events(Wakeup, out, home,
7_0 will give you individual settings for each day from Monday to Sunday.
out, home,sleep) and 2 days(Saturday and Sunday) with the same six events.
out,home,sleep) and 1 day(Sunday) with the same six events.
Frost protection.
This feature is to avoid room temperature going below 5
°C
E0 = The internal sensor has developed a fault. You should contact your thermostat retailer for assistance.
E1 = The remote floor sensor has not been connected, has been wired incorrectly or the probe is faulty.
LO = The room or floor temperature is below 0
Error
Message
°C
HI = The room or floor temperature is above 50
°C
Program button( when thermostat is turned on)
means the thermostat will switch the heating on
0.5°C below the set temperature and
will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch
on 1°C below the set temperature and switch off 1°C above the set temperature.
1°C 1°C ~ 5°C
-5°C ~ +5°C
0
°C -5°C ~ +5°C
CS-11 LCD 7-Day 5+2 Programmable Digital Thermostat
U9310044
Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW
Tel: 01993 824900 : www.emmeti.co.uk : e: sales@emmeti.co.uk
Temporary
set temperature and on again to reach the set temperature.The default is 1°C which
To temporary override the current set temperature,
1. Press up or down button once, the set temperature starts flashing
2. Press up or down button again until the temperature you want is displayed
3. Press to confirm the setting with shown on LCD
Now your thermostat will override the current programming and maintain the new set
and hold button for 5 seconds until disappears.
Press button M to select Auto/Manual mode. In Manual mode, the thermostat maintains a constant set
temperature manually set by the user. In Auto mode, the thermostat executes the preprogrammed schedules.
To adjust these schedules, follow the easy steps below,
To set vacation mode press and hold the up button for 5 seconds until appears. Use
same procedure to exit this mode.Vacation mode
up or down button to change the set point and wait for 5
will maintain a set temperature(default
Your thermostat has the ability to reset all settings to the factory defaults. If you are
certain you want to do this: In standby mode(when thermostat is turned off), press
If thermostat is set in AF model, press and hold the down button for 5 seconds,
floor temperature will show and it will automatically revert back to room temperature
This product should be installed by
a qualified electrician.
Installation and Wiring
86mm
mm68
Rear View
45mm
13mm
27 mm
26 mm
Side View
60mm
mm68
86mm
4mm
mm7
LL
LOAD
(16A)
FEED
(220VAC+/-15%)
Floor Sensor
(or remote air sensor)
NN
To lock the buttons, press and hold the up and down buttons for 5 seconds until you
see a lock icon appearing, to unlock, repeat the steps above.
and hold
button M and for 5 seconds until “RES” is shown for 5 seconds on LCD.
This thermostat is fitted with a real time clock. It is essential that the clock time and day
are set accurately if you require your programmed events to start on time. Follow the
Set the Time and Day
Auto / Manual Mode
Program your thermostat
Resetting factory defaults
Lock the buttons
View floor temperature
Temporary temperature override
Vacation mode
Press the button once
Use up or down button to change the time (Hold up or down button to change
Press button again, the day of the week will flash
Press button again to accept and exit
Use up or down button to change the day of the week
Press and hold button M for 5 seconds until “Program” is shown with the Day flashing. Use up or
down button adjust the day (hold up or down button for 5 seconds to set all days the same).
Press button M again and use up or down button to set the desired temperature to be
Press button M to bring up the program 1. Use up or down button to set the start time
To skip program 2 ,3,4,5 for Saturday and Sunday, simply adjust the set temperature for program
To skip program 3 and 4, simply adjust the set temperature for program 3 and 4 to the same set
temperature as program 2.
2 ,3,4,5 to the same set temperature as program 1.
and the time will flash Step 1.
Step 2.
Step 3.
Step 4.
Step 5.
10
°C
) all the time. Press
Carefully separate the front half of the thermostat
from the back plate by placing a small flat head
terminal driver into the slots on the bottom face of
the thermostat
1
1
2
3
Carefully unplug the ribbon connector
which is plugged in to the front half of
the thermostat
2
Place the thermostat front half somewhere
safe. Terminate the thermostat as shown
in the diagrams below
3
Screw the thermostat back
plate on to the back box
4
Re-connect the thermostat ribbon cable
and clip the two halves together
5
(default 06:30).(Hold up or down button to change by 15 minutes each time.)
Programme Start time Setpoint
maintained for program 1.(default 21
°C
)
below easy steps,
by 15 minutes each time.)
seconds to accept and exit.
temperature until the next program period begins. To cancel the override setting, press
in 5 seconds.
CS-11 LCD 7-Day 5+2 Programmable Digital Thermostat
U9310044
Wiring Diagram
123456
SWL
Sensor
Remote
out used L
Not
230V AC
N
~~
Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW
Tel: 01993 824900 : www.emmeti.co.uk : e: sales@emmeti.co.uk
“ Temporary ”
“ Temporary ”
Repeat and unitl you finish the settings for 6 programmes. Press
button M to accept and exit.
The below is the default factory settings for the 6 programmes.
2 3
1
2
3
4
5
6
06:30
08:30
11:30
13:00
16:30
22:30
21°C
16°C
16°C
16°C
21°C
16°C
Note: It is faster to program the same schedule for the entire week and then to adjust the exceptional days.
1. Please ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote sensor connected to it are in accordance with BS 7671, the latest edition of the IET
Wiring Regulations.
2. The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the current safety standards and with a contact separation of at least 3 mm in all poles.
3. Before commencing work on the installation, the electricity supply must be disconnected.
4. The depth of the back box should be 35mm minimum.
WARNING