Elektrobock PT712-EI Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Elektrobock PT712-EI (8 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
MADE IN CZECH REPUBLIC
including external sensor
backup in case of voltage failure > 100 hours
direct installation on junction box
well-arranged backlit display
VENUS switch design
N L COM NO N L COM NO
L'
2
DESCRIPTION
PT712-EI is a digital thermostat with a room and oor sensor, specially designed for electric oor heating
control. The internal-external sensor combination enables the regulation of:
1) fl oor temperature (external sensor) - suitable, for instance, for bathrooms where a warm fl oor is
desirable, irrespective of the room temperature;
2) room temperature (internal sensor) - when comfortable room temperature is required;
3) combined (both sensors) - the internal sensor scans the room temperature, while the
external one monitors the maximum fl oor temperature;
comfortable room temperature is required, however, with
simultaneous monitoring of the fl oor temperat (suitable for wooden
and laminated fl oors).
Another advantage is simple installation in the KU/KP68 junction boxes by means of the PLUG-IN
system, as well as the possibility of setting 2 weekly programs with 6 temperature changes per day.
INSTALLATION AND LOCATION
Install the thermostat in a suitable place (minimum height of 1.2-1.5 m above the oor) where its operation
will not be affected by direct hot/cold air fl ow, sunshine or other disturbing infl uences. Do not mount the
thermostat on an exterior wall either. In rooms with increased humidity (bathroom, kitchen), observe valid
standards and install the thermostat as far from the bathtub, shower, basin or sink as possible.
The external oor sensor (type CT04-10k, CYXY 2 x 0.5 mm, 10 k:, lenght 3 m, PVC plastic case)
must be located in a exible plastic tube embedded in the oor, as near to the surface as possible. The
tube must be sealed and protected against in-leak of building materials so that the fl oor sensor can be
replaced easily, if need be. It must not run parallel with power conductors! It can be extended to
a maximum length of 30 metres. The installation can only be done by a properly qualifi ed person!
Disconnect power supply before installation!
1) Switch off the main circuit breaker.
2) Check that the junction box is placed parallel with the wall.
3) Separate the power part of the thermostat from its microprocessor (main) part; see Fig. 1.
4) Pull the connecting terminals out of the thermostat rear part, see Fig. 2.
5) Connect conductors to the terminals acc. to the wiring diagram below, see Fig. 3.
6) Insert the terminals into the thermostat terminals and fasten the power part to the junction
box, see Fig. 4 and 5.
7) Insert the main part connector into the power part and push it; the metal springs must
t in the given holes, see Fig. 6 and 7.
8) Switch on the main circuit breaker; the thermostat is ready for operation. LCD backlight becomes active only
after charging the backup battery (up to 24 hours).
9) Set the constant 4 (page 6) according to the load, this could cause an inaccurate display of the current
temperature.
Note: We recommend you test correct connection after installation, see the TEST function (page 7).
Wiring diagram: Fig. 1
When using the low tariff
L‘ = disconnected phase
power part main part
PULLPULL
connecting
terminals
HEATING
HEATING
NTC 10k NTC 10k
* P= max. 2760 W
MENU
3
DESCRIPTION OF LCD AND CONTROL BUTTONS
1, Current date (in the Prog mode, selection of number of days for
programming)
2, Operating modes: OFF/PROG/AUTO/MANU/case=HOLIDAY
3, Current room temperature
4, Indication of room temp. measurement by the exter. sensor.
5, Heating on indication
6, Button lock indication
7, CLOC mode indication (current date and time setting)
8, Required temperature and current time display / listing of operating
modes (this line is explained in detail with every mode)
9, Battery supply indication (in case of 230V/50Hz voltage failure,
it is functional only after 1 day of operation, when the backup
battery is charged!)
10, Indication of setting the external sensor as the fl oor one
11, Anti-freeze temperature of 3 °C
MENU button:
short press = opens the main menu and
confi rmation (ENTER)
long press (approx. 3 sec.) = back from the
main menu
/ button:
basic mode = opens info
main menu =browse and set current values
simultaneous press of the MENU and
buttons (in basic mode) = key lock
simultaneous press of the MENU and
buttons (in basic mode) = key unlock
simultaneous press of the MENU and /
buttons (in main menu) = return to basic mode
Note: The LCD backlight is activated by pres-
sing any button!
Fig. 2 Fig. 3 Fig. 4
Fig. 5 Fig. 6 Fig. 7
NL
NO COM
PULL out the connecting terminals. Connect according to the wiring diagram.
PUSH the connecting
terminals in.
Screw the power part to
the junction box.
Connector and holes
for metal springs.
PUSH the
main part
onto the
power part.
9


Product specificaties

Merk: Elektrobock
Categorie: Thermostaat
Model: PT712-EI

Heb je hulp nodig?

Als je hulp nodig hebt met Elektrobock PT712-EI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden