Dri Eaz HEPA 700 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dri Eaz HEPA 700 (11 pagina's) in de categorie Luchtreiniger. Deze handleiding was nuttig voor 4 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/11
124775B HEPA 700 1 Legend Brands, Inc.
Owner s
Manual
HEPA 700 Air Scrubber
The HEPA 700 draws air in from the surrounding environment and passes it through an advanced ltration
system. The unit removes airborne particles such as dust, mold spores, pollen, pet dander and other debris, and
odors, and can be congured for negative or positive-pressure ltration setups.
R E A D A N D U N D E R S T A N D B E F O R E O P E R A T I N G
ELECTRIC SHOCK HAZARD
The unit must be electrically grounded. Use only on
GFCI protected receptacles.
Connect to a properly grounded outlet only. Do not cut
o the grounding prong. Do not use with an adapter.
Do not use with extension cords.
Do not use with damaged cord or plug. If unit is not working as
it should, has been dropped, damaged, left outdoors, or
exposed to water, return it to an authorized service center for
repair.
Unplug cord from outlet when not in use or when servicing unit.
ELECTRIC SHOCK HAZARD
Keep motor and electrical parts dry.
Do not use outdoors. For indoor use only.
Do not handle plug or unit with wet hands.
Do not operate unit in standing water.
BREATHING HAZARD
When using the HEPA 700 in a containment area, turn
o all sources of power to open combustion
appliances such as replaces, boilers, furnaces, water
heaters and HVAC systems to avoid the risk of backdrafting
deadly carbon monoxide fumes.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy, and if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for
help
ATWINC3400-MR210CA module approvals:
United States/FCC ID: 2ADHKWINC3400
Canada/ISED:
o IC: 20266-ATWINC3400
o HVIN: ATWINC3400-MR210CA
o PMN: Wi-Fi and Bluetooth Module
Parts Identication
Inlet and
inlet cover.
Remove
cover
before
operating.
Air intake
ring. Attach
14 in. semi-
rigid ducting.
Feet for
horizontal
operation &
stacking.
Carry handle.
Folds down when
not in use.
Filter cover buckle
(×4). Release to
replace lter
elements.
Use the hook- d-pile an
fasteners to attach the inlet
cover here while unit is use.
115V outlets
(×2) and
breaker reset
switch.
outlet. Filter
retainer ring may
be used to
attach in. 14
diam. layat
Control panel.
124775B HEPA 700 2 Legend Brands, Inc.
HEPA 700 APPLICATIONS
Water Damage
Construction Dust Control
Mold Remediation
Odor control
The HEPA 700 can be used for dust Other uses:
abatement, re damage remediation, jobsite ventilation,
and positive or negative air setups for contamination
cleanup and cleanroom environments. Use in homes,
businesses, institutions, schools, hospitals, long term care
facilities, construction and remodel job sites.
NOTICE! Many of these applications can present
signicant health risks and require professional training.
Because federal, state/provincial, and local laws
and regulations have varying requirements for the
application, testing and general use of equipment on
asbestos abatement projects, Legend Brands cannot
warrant products for asbestos abatement. Contractors
performing abatement work should evaluate tools,
equipment and procedures in light of their local regulatory
requirements, and comply with those requirements.
WARRANTY REGISTRATION
Register at . If you
Warranty.LegendBrandsRestoration.com
determine service is required, have your equipment model,
serial number and original proof of purchase available and call
your distributor to obtain a return material authorization (RMA)
or email service@legendbrandsrestoration.com.
SPECIAL FEATURES
Command Hub Technology
Integrated Command Hub technology with the free Command
Center mobile app enables rmware updates and 24/7
monitoring and control to ensure optimal air ltration. (App
available soon in Apple and Google Play stores.)
Ducting options
Inlet: in. wire reinforced ducting (purchased separately). 14
Outlet: (diameter) layat or wire reinforced ducting 14 in.
(purchased separately) using the provided duct attachment
ring. Take care not to bend or otherwise damage the
attachment ring when installing the ducting. Do not exceed a
maximum ducting length of 7.6 m. 25 ft. /
Negative Pressure Setup
The HEPA 700 can be set up for a negative pressure
containment area. Only professionals with the appropriate
training should set up negative pressure containment areas.
Stacking for Storage and Operation
Stack the HEPA 700 up to three high for storage or transport.
Secure the units when stacked for transport.
The unit can also be operated on its back, with the outlet
facing upward.
CONTROLS AND OPERATING
INSTRUCTIONS
Setup
1. Unwrap the cord completely.
2. Place the HEPA 700 with the handle up. Ensure that neither
the inlet nor the outlet are obstructed.
3. 115V Plug a standard in to GFCI-protected outlet.
Electrical Outlets
You can connect up to eight (8 HEPA 700s on a 15-amp )
circuit on the lowest speed; four (4) on the highest speed .
Command Hub - Home
On/Off. Swit unit on or o ches .
Use + / - to adjust blower speed.
Menu. Select to view system info, service, error
messages, wireless setup, settings, and other information. Go
to HEPA700.legendbrandsrestoration.com for more info.
GFCI Outlet Reset and Test
MAINTENANCE
ELECTRIC SHOCK HAZARD. Disconnect from
electrical supply prior to servicing or cleaning.
BREATHING HAZARD. Always wear an
appropriate NIOSH-approved respirator and
personal protective equipment when removing or
replacing lters, or when cleaning the HEPA . 700
About the lters
IMPORTANT: Use Legend Brands HEPA 700lters only
(see Filter Options below). Use of other lters will
reduce filtration effectiveness.
Regularly check and replace the prefilter(s) and HEPA
primary lter as needed. The control panel will indicate
when the HEPA primary filter needs to be replaced.
Filters are not reusable. Do not attempt to clean and reuse.
NOTICE: When using the HEPA 700 on remediation
projects, change BOTH lters after every job. Dispose of
contaminated lters properly.
Replacing the Prefilter
The prefilter should be replaced more frequently to help
preserve the life of the HEPA lter.
1. Lay unit on its back and release the four (4) buckles. Lift o
the lter door.
WARNING
WARNING
WARNING
WARNINGWARNING
124775B HEPA 700 3 Legend Brands, Inc.
2. Remove the prelter from the lter door and discard.
3. Insert new prelter into lter door. Ensure that the prelter is
seated properly on the retention tabs.
4. To replace the HEPA Primary lter, proceed to the next step.
Otherwise, replace lter assembly on to unit and reattach the
four buckles.
Replacing the HEPA Primary Filter
IMPORTANT: Performance is reduced when a non-Legend
Brands primary lter is installed. For maximum ltration
performance, use only Legend Brands lters. Do not clean
and reuse the HEPA lter. Always replace the prelter when
replacing the HEPA lter.
1. Lay unit on its back and release the four (4) buckles. Lift
o the lter door.
2. Remove the prelter from the lter door and discard.
3. Release the two locking tabs and lift out primary lter
element. Discard used lter.
4. Replace HEPA primary lter, handling it with care, as lter
is easily damaged. Do not use a lter that is damaged.
5. Place new prelter(s) in lter door. Replace lter cover and
lock the four buckles securely.
Before each use
Inspect the electrical cord for damage, and do not e the unit us
if you nd any fraying, cuts, etc. Contact your local distributor
for service.
As Needed
Clean exterior of housing and inside the lter compartment.
Ensure housing is completely dry before reassembling. Do not
apply liquids to control panel or to any electrical components.
When using the HEPA 700 for remediation or in
sensitive environments:
Wear NIOSH-approved protective gear when changing
lters.
Change both lters after every remediation job.
Dispose of used lters according to local regulations.
Replace both the prelter and HEPA filter to prevent
cross-contamination.
Clean the unit thoroughly (vacuum and damp wipe per
IICRC S520, 10.11) before removing it from the
containment area to avoid cross-contamination. Let the
unit dry before installing clean lters.
For parts and service contact your local distributor or Legend Brands: Live Chat - Info.legendbrands.com | Email:
Service@legendbrandsrestoration.com
Filter Options
Air Filtration Applications:
Prelter(s)
Removes larger
particulates protects
primary lter
Specialty Prelter
Carbon removes
VOCs and odors
Primary lter (HEPA)
Removes ne particulate
down to .3 microns
Water loss air ltration and mold
remediation*
For high particle Standard air scrubbing.
loads, such as construction or remodeling sites.
2-in. MERV 8 Pleated
Paper Filter
#125026 (6 pk.)
HEPA Filter
#124966 (1 pk.)
#125028 (8 pk.)
For removing Odor control and air ltration.
volatile organic compounds (VOCs), fumes from
paint and paint thinners, and many other
noxious odors, eg, from food, sewage, etc.
Paper Smoke particulate and odor removal.
prelter and HEPA lter remove particulates
and carbon lter adsorbs odors.
1-in. MERV 8 Pleated
Paper Filter
#125029 (12 pk.)
1-in. Activated
Carbon Filter
#125027 (4 pk.)
HEPA Filter
#124966 (1 pk.)
#125028 (8 pk.)
SPECIFICATIONS
Model
HEPA 700 (#125105)
Airow
Variable to 700 CFM | CMH 1189
Static pressure
3.0 in. (H2O) | 747 Pa
Weight
42.0 lbs. | 19.1 kg
Dimensions
(H × D × W)
22.8 × 17.0 × 25.9 in.
57.9 × 43.3 × 65.9 cm
Amps/Power
1.5 - 3.0 amps, 115v, 60 Hz, 350w
Power cord
25 ft. | 7.6 m
Duct size
14 in. | 35.6 cm
Construction
Injection-molded plastic housing
Xactimate
WTRNAFAN>
Safety
ETL listed to UL 507 and CSA C22.2 No. 113
Specications are subject to change without notice. Some values
may be approximate.


Product specificaties

Merk: Dri Eaz
Categorie: Luchtreiniger
Model: HEPA 700

Heb je hulp nodig?

Als je hulp nodig hebt met Dri Eaz HEPA 700 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Luchtreiniger Dri Eaz

Handleiding Luchtreiniger

Nieuwste handleidingen voor Luchtreiniger