Dri Eaz LGR 7000XLi Handleiding

Dri Eaz Luchtreiniger LGR 7000XLi

Lees hieronder de 📖 handleiding in het Nederlandse voor Dri Eaz LGR 7000XLi (6 pagina's) in de categorie Luchtreiniger. Deze handleiding was nuttig voor 35 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
108261S #108110 (F412) Legend Brands, Inc. 1
Owners Manual
LGR 7000XLi Portable Dehumidifier
Model #108110 (F412)
LEGEND BRANDS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932 3030 757 7950- Fax: 360- - LegendBrandsRestoration.com
The Legend Brands® s LGR 7000XLi dehumidifier reduce humidity in enclosed environments by
removing water vapor from the air. The 7000XLi is rugged, durable and highly portable making ,
it ideal for water damage restoration, structural drying, construction, and other applications
requiring temporary, humidification. -high performance de
Patents: http://www.LBpatents.com
R E A D A N D U N D E R S T A N D B E F O R E O P E R A T I N G
WARNING! Do not alter or modify your unit in any
way. Use only replacement parts authorized by
Legend Brands. Modifications or use of unapproved
parts could create a hazard and will void your
warranty. Contact your local distributor for
assistance.
WARNING! Electric shock hazard, rotating fan, hot
surface hazards. Unplug unit before opening cover
for cleaning or servicing. nit must be grounded. U
Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
-Insert three prong plug on power cord into a
matching electrically grounded outlet. Do not use
adapter. Never cut off third prong. Do not use an
extension cord.
The unit must be operated on a 120V/60Hz circuit
protected by a Ground Fault Circuit Interrupter
(GFCI) device.
Keep motor and wiring dry.
Do not attempt to repair the unit. For Authorized
Service Centers, contact Legend Brands.
NOTICE: Do not use in environments where
corrosive chemicals are present, such as chlorine.
INTRODUCTION
LGR (low grain refrigerant) dehumidifiers utilize an -
internal pre-cooling system to boost water removal
efficiency. LGR units can continue to remove moisture in
drier environments where conventional refrigerants
cannot.
OPERATING YOUR DEHUMIDIFIER
Set unit upright
NOTICE: Transporting or storing the unit in a
horizontal position is not recommended. When the
machine is placed in a horizontal position, the oil
from the compressor can flow into the refrigerant
coils and reduce the ability of the dehumidifier to
function and possibly damage the unit. If the unit
has been placed in a horizontal position, set it
upright and let it stand for at least 30 minutes before
turning it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an
enclosed area. Close all doors and windows that
open to the outside to maximize the unit’s water
WARNING
WARNING
WARNING
WARNINGWARNING
CORRECT PLUG REMOVAL
Grasp IEC plug and pull straight out
IMPORTANT: Damage to IEC receptacle or
dehumidifier resulting from improper removal
of the power cord is not covered by warranty.
The IEC power cord is a wear item and is not
covered by warranty.
108261S #108110 (F412) Legend Brands, Inc. 8
SPECIFICATIONS
Model (#108110) LGR 7000XLi
Water removal AHAM
(80°F/60% RH)
130 pts. | 61.5 liters / day
Water removal low grain
(80° F/20% RH)
17 pts. | 8 liters / day
Process air (max.) - 325 CFM* ductable floor level outlet.
Dimensions
(H × D × W)
33.5 × 20 × 20 in. | 85 × 51 × 51 cm
Weight 107 lbs. | 49 kg
Amps 8.3A
Volts 115V
Frequency 60Hz
Noise level (avg.) 62 dB
Air filter Part no. #100250 (F581) (24 pack)
Drain hose 40 ft. | 12.2 m
Power cord 25 ft. | 7.6 m
Construction Rotomolded shell
Safety ETL certified CSA 22.2 no. 92
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
Warranty information is available at
LegendBrandsRestoration.com.
Be sure to visit Warranty.LegendBrandsRestoration.com
and register your purchase. Your registration will help us
provide you with updated product information as needed.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
WARNING: This product may expose you to
chemicals, including lead and phthalates, known
to the State of California to cause cancer, birth defects,
or other reproductive harm. For more information, go to
P65Warnings.ca.gov
108261 14S #108110 (F412) Legend Brands, Inc.
TRANSPORTE Y ALMACENAMIENTO
AVISO: Maneje la unidad con cuidado. No la deje caer,
ni la aviente, ni la coloque en un lugar en que pueda
caerse. Si maneja la unidad sin el debido cuidado, ésta
puede dañarse y causar algún peligro o anular la
garana.
No exponga el panel de control a la humedad, la
nieve ni la lluvia.
Guárdelo y transpórtelo de forma segura para evitar
cualquier efecto perjudicial en las partes internas.
Amarre durante el transporte para evitar que se
deslice y lastime a los ocupantes del vehículo.
Consejo especial para el transporte en escaleras:
Antes de cargar la unidad en escaleras, siga estos
pasos adicionales para asegurar que se elimine toda el
agua:
1. Apague la unidad una vez que haya terminado el ciclo
de descongelación. Agite suavemente la máquina en
posición vertical sobre sus ruedas para asegurarse de
que el agua que quede en las superficies interiores
caiga al área del recolector.
2. Presione la tecla PURGA. Cuando el ciclo de purga
haya finalizado, apague la unidad.
3. Retire la manguera de drenaje externa, escúrrala con
cuidado y vuelva a colocarla en el compartimento lateral
de la unidad.
4. IMPORTANTE: Quite el cable de alimentación,
enrollelo cuidadosamente y colóquelo en el bolsillo
de almacenamiento del cordón.


Product specificaties

Merk: Dri Eaz
Categorie: Luchtreiniger
Model: LGR 7000XLi

Heb je hulp nodig?

Als je hulp nodig hebt met Dri Eaz LGR 7000XLi stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Luchtreiniger Dri Eaz

Handleiding Luchtreiniger

Nieuwste handleidingen voor Luchtreiniger