Drayton Digistat 3i Handleiding
Drayton
Thermostaat
Digistat 3i
Lees hieronder de 📖 handleiding in het Nederlandse voor Drayton Digistat 3i (2 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 57 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
14.Continue to press “SET?”
button until you return to
normal operating mode with
a display similar to the one
shown here.
OPERATING MODES
The Digistat can be operated in one of three modes.
1) – Timed, all preset times and temperatures
2) – Continuous night temperature (useful for low
limit temperature protection when on holiday)
3) – Continuous ‘DAY 1’ temperature
Use the SELECT button to change the operating mode to
suit your requirements, the symbols are positioned on the
right hand side of the display.
TEMPERATURE OVERRIDE
If at anytime during normal operation, you wish to
temporarily increase or decrease the set temperature use
the + or – buttons to change to your desired setting. This
can be done without entering the SET mode. Five seconds
after releasing the + or – button the display will revert to
showing the actual room temperature. The Digistat will
now control the temperature to the override setting until
the next programmed switching time, when it will revert to
the times and temperatures you have already programmed.
BATTERY REPLACEMENT
30 days before the batteries need re-
placing, a battery symbol will flash in the
right hand side of the display (Diagram
C). This signifies that two 1.5V type
AA alkaline batteries will be
needed to replace the existing ones.
If battery replacement is carried out in this condition the
programmed settings will only be held in the memory for a
maximum of one minute, after which re-programming may
be necessary.
IMPORTANT
To avoid the possibility of having to
re-programme the switching times and
temperatures, it is advisable to wait
until the display with a flashing battery
symbol changes to a continuous
battery only display (after 30 days
Digistat 3i
User instructions
– Diagram D). In this condition the unit will remain OFF but
your programmed settings will be held in memory for a number
of weeks. The battery compartment can now be left open, to
replace the batteries, for approximately one hour. If the
compartment is left open for longer, the unit will revert to the
factory preset times and temperatures. It may be necessary to
reset the correct time of day after changing the batteries.
The battery compartment is situated at the bottom of the
unit (press to unlatch and slide down). Ensure new batteries are
installed correctly.
HELPFUL HINTS
1) First/Last Set Times
The Day 1 setting cannot be programmed before 12.00
midnight. The night setting can be programmed at whatever
time you require, even after 12.00 midnight so long as it is not
programmed more than 23 hours 50 minutes after the Day 1
setting.
2) Part or Full Day Omission
If during programming the Digistat, one of the symbols on the
left hand side of the screen starts to flash, this indicates that two
or more of the switching times have been set to the same time.
This facility enables you to omit one or more of the switched
periods. When one or more switching times are programmed
together the later setting takes precedent. For example, if all
four switching times were set together the Digistat would
control continuously at the fourth (night) temperature setting .
3) Programme Sequence
The Digistat will not allow you to program the switched periods
out of sequence but will hold the times together as stated above.
4) Reset
If at any time during the programming you get confused and
would like to start the procedure from the beginning press the
SELECT and – buttons at the same time and hold for two
seconds. This resets the Digistat to the factory preset times and
temperatures shown in the table (overleaf).
5) Self Revert
If during programming no button is pressed for between
one and two minutes the Digistat will revert automatically to its
normal operating mode.
1
Diagram C
Diagram D
1
CONFORMS TO THE ESSENTIAL
REQUIREMENTS OF THE FOLLOWING
DIRECTIVES:
89/336/EEC – Electromagnetic compatibility
73/23/EEC – Low voltage directive
+
Drayton
Invensys Climate Controls Limited
Cordwallis Street, Maidenhead
Berkshire SL6 7BQ
Telephone: (01628) 672121
Sales Facsimile: (01628) 675062
Technical Helpline: (01895) 460444
An Invensys Product
Invensys Climate Controls reserve the right to make changes without 090 799
notice and cannot accept liability for errors. 0200
Digistat 3i
user instructions
The Digistat 3i features unique self learning optimum start
software. They can help achieve savings in excess of 10% on
heating costs and reduce CO2emissions, by delaying the start
time on milder days without affecting your comfort level.
USER INSTRUCTIONS FOR OPTIMUM
START
There is no extra programming involved. The self learning
software is factory preset and will start to monitor and adjust
the heating start times for setting , as soon as the unit is
installed.
The optimum start feature only operates on the first
switching time of each day ( ). Switching times
, and switch at the programmed times without any
delay.
The delay period can vary between 0 - 60 minutes
depending on:
a) The actual room temperature at the first switching time
( ).
b) The set temperature of the Digistat 3i.
c) The stored data on how fast the heating system
responded the previous day.
During normal operation the flame symbol on the
display indicates the current operating status.
Flame on = heating on
No flame = heating off
FIashing flame = saving energy (optimum start cycle
operating)
When the flame is flashing, the optimum start cycle can be
overriden by pressing the button once. This returns the
unit to normal operation.
5. Press “SET?” button twice to return
to normal operating mode.
PRE-PROGRAMMED TIMES AND
TEMPERATURES
The Digistat 3i comes with the following preset programme.
Symbol Mon-Fri Sat-Sun Temperature
Time Time
6.30 7.00 20°C
8.30 9.00 16°C
4.30 pm 4.00 pm 21°C
10.30 pm 11.00 pm 7°C*
* 16°C if selector pin removed, see installation instructions
TO VIEW OR CHANGE THE FACTORY
SETTINGS (steps 6-14)
6. Press the “SET?” button until this
display is shown.
7. Press the Yes (–) button. You have
selected the Monday to Friday part
of the programme.
8. Press the Yes (–) button again. This
tells you that at 6.30, the heating
system will control your home at
20°C. If you wish to alter the temp-
erature use the + and – buttons.
9. Press the “SET?” button. The
time will now flash. If you wish
to alter the switching time use
the + and – buttons. This will
change the switching time in
10 minute steps.
10. Press the “SET?” button, this
tells you that at 8.30, the
heating system will control
your home at 16°C. If you wish
to alter this temperature use
the + and – buttons.
11. Continue to press the “SET?”
button as in steps 9 and 10
above to advance through the
times and temperatures for
Mon. to Fri. (1-5). If you wish to
alter any of the times and
temperatures use the + and
– button, when the one you
wish to alter is flashing.
12 .Once Mon. to Fri. have been
set, the display will show as
here. This means do you want
to set the times for Monday (1)
differently from the rest of the
week? If you do, press the Yes
(–) Button, and follow the
routine as steps 9 to 11.
13.Continue to press the “SET?”
button to advance through
the week (1 – 5). When the
display is as shown here, press
the Yes (–) button if you wish
to view or alter the times for
Sat.-Sun. (6-7). Repeat steps
9-12 as required.
INITIAL START UP
Open the battery compartment situated
at the bottom left hand corner (press
to unlatch and slide down). Remove the
insulator strip from between the
batteries and their contacts and close
the compartment.
The unit will now display the actual
room temperature and time at 12.00
midnight (Diagram A).
If the unit has been stored in a cold
place, it may take time to warm up.
Digistat 3i has an indicator to show
when the heating system is ON or OFF, e.g. if the SET
temperature is 20°C and the actual room temperature is below
20°C a flame symbol will appear on the display (Diagram B).
This indicates a demand for heat (system will switch ON).
During normal operation, the Digistat 3i will display actual
room temperature continuously.
SETTING THE TIME OF DAY (steps 1-4)
The diagram next to each step description shows resulting display.
1. Press “SET?” button
2. Press “Yes” (–) button. The hours
will flash as this diagram. Use the +
and – buttons to set correct hour.
3. Press “SET?” button again and the
minutes will flash, use + and –
buttons to set correct minute time.
4. Press “SET?” button, day of the week
will flash, 1= Monday, 7= Sunday, use
+ and – buttons to set correct day.
SYSTEM OFF
SYSTEM ON
Diagram A
Diagram B
Continued overleaf
+
Product specificaties
Merk: | Drayton |
Categorie: | Thermostaat |
Model: | Digistat 3i |
Heb je hulp nodig?
Als je hulp nodig hebt met Drayton Digistat 3i stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Thermostaat Drayton
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
21 Augustus 2024
Handleiding Thermostaat
- Thermostaat Bosch
- Thermostaat Panasonic
- Thermostaat Bticino
- Thermostaat AEG
- Thermostaat ATAG
- Thermostaat Honeywell
- Thermostaat Junkers
- Thermostaat Nefit
- Thermostaat Remeha
- Thermostaat Siemens
- Thermostaat Vaillant
- Thermostaat ACV
- Thermostaat Agpo Ferroli
- Thermostaat Alecto
- Thermostaat Ambiano
- Thermostaat Amfra
- Thermostaat Arnold Rak
- Thermostaat AVM
- Thermostaat AWB
- Thermostaat Basetech
- Thermostaat Berker
- Thermostaat Boneco
- Thermostaat Brennenstuhl
- Thermostaat Brink
- Thermostaat Bryant
- Thermostaat Buderus
- Thermostaat Bulex
- Thermostaat Daikin
- Thermostaat Danfoss
- Thermostaat De Dietrich
- Thermostaat Devi
- Thermostaat Devolo
- Thermostaat Dimplex
- Thermostaat Drayton Erie
- Thermostaat Easy Timer
- Thermostaat EasyTemp
- Thermostaat EBERLE
- Thermostaat Econo-Heat
- Thermostaat Elco
- Thermostaat Elektrobock
- Thermostaat Elgato
- Thermostaat Eliwell
- Thermostaat Elro
- Thermostaat ELV
- Thermostaat Emerson
- Thermostaat Emmeti
- Thermostaat Enda
- Thermostaat Eneco
- Thermostaat EQ-3
- Thermostaat Eqiva
- Thermostaat Essent
- Thermostaat Etherma
- Thermostaat Eurotronic
- Thermostaat Extraflame
- Thermostaat Ferguson
- Thermostaat Ferroli
- Thermostaat Finder
- Thermostaat GE
- Thermostaat Gira
- Thermostaat Go Green
- Thermostaat Google
- Thermostaat Grasslin
- Thermostaat Grohe
- Thermostaat Hager
- Thermostaat Hama
- Thermostaat Helios (Amfra)
- Thermostaat HomeMatic
- Thermostaat Hornbach
- Thermostaat HQ
- Thermostaat Hugo Muller
- Thermostaat Hunter
- Thermostaat ICY
- Thermostaat Intergas
- Thermostaat IR-V
- Thermostaat Itho
- Thermostaat Itho-Daalderop
- Thermostaat Landis Gyr
- Thermostaat Levica
- Thermostaat Lowes
- Thermostaat Magnum
- Thermostaat Max
- Thermostaat Muller
- Thermostaat Nest
- Thermostaat Netatmo
- Thermostaat Niko
- Thermostaat Nobo
- Thermostaat Noma
- Thermostaat Perel
- Thermostaat Plieger
- Thermostaat Plugwise
- Thermostaat Profile
- Thermostaat Radson
- Thermostaat REMKO
- Thermostaat Renkforce
- Thermostaat RWE
- Thermostaat Salus
- Thermostaat Saunier Duval
- Thermostaat Schneider
- Thermostaat Silvercrest
- Thermostaat Somfy
- Thermostaat Stiebel Eltron
- Thermostaat Sygonix
- Thermostaat Tado
- Thermostaat Taurus
- Thermostaat Techno Line
- Thermostaat Technoline
- Thermostaat Tesla
- Thermostaat TFA
- Thermostaat Theben
- Thermostaat THERMAFLEX
- Thermostaat Thermy
- Thermostaat TP Link
- Thermostaat Trotec
- Thermostaat Truma
- Thermostaat UPM
- Thermostaat Vasco
- Thermostaat VDH
- Thermostaat Velleman
- Thermostaat Viessmann
- Thermostaat Wachendorff
- Thermostaat Watts
- Thermostaat Webasto
- Thermostaat Weishaupt
- Thermostaat Westfalia
- Thermostaat Wolf
- Thermostaat Worcester-Bosch
- Thermostaat Xavax
- Thermostaat Z-Wave
- Thermostaat Zehnder
- Thermostaat Johnson Control
- Thermostaat Jung
- Thermostaat Oertli
- Thermostaat OJ ELECTRONICS
- Thermostaat Orbis
- Thermostaat Oregon Scientific
- Thermostaat Otio
- Thermostaat Schwaiger
- Thermostaat Fenix
- Thermostaat Conrad
- Thermostaat Corberó
- Thermostaat EMOS
- Thermostaat King
- Thermostaat Cotech
- Thermostaat Avidsen
- Thermostaat Hive
- Thermostaat Kemot
- Thermostaat Coati
- Thermostaat Nexa
- Thermostaat SPC
- Thermostaat Baxi
- Thermostaat Aube
- Thermostaat Carrier
- Thermostaat Cepra
- Thermostaat Delta Dore
- Thermostaat ELKO
- Thermostaat Fantini Cosmi
- Thermostaat Heatmiser
- Thermostaat Heimeier
- Thermostaat Horstmann
- Thermostaat IMIT
- Thermostaat Oventrop
- Thermostaat Seitron
- Thermostaat TrickleStar
- Thermostaat Tylö
- Thermostaat Vemer
- Thermostaat Warmup
- Thermostaat Fibaro
- Thermostaat Energenie
- Thermostaat Mikoterm
- Thermostaat Ariston Thermo
- Thermostaat Carel
- Thermostaat Busch-Jaeger
- Thermostaat EVE
- Thermostaat Optima
- Thermostaat Frico
- Thermostaat EQ3
- Thermostaat Homematic IP
- Thermostaat Computherm
- Thermostaat Wattio
- Thermostaat Crestron
- Thermostaat ORNO
- Thermostaat POER
- Thermostaat Heatit
- Thermostaat 2Heat
- Thermostaat Veria
- Thermostaat ThermoSmart
- Thermostaat Yokis
- Thermostaat Vimar
- Thermostaat PECO
- Thermostaat H-Tronic
- Thermostaat Intertechno
- Thermostaat Tru Components
- Thermostaat Emko
- Thermostaat Innogy
- Thermostaat Wallair
- Thermostaat Maico
- Thermostaat HomePilot
- Thermostaat Ouellet
- Thermostaat ChiliTec
- Thermostaat Tellur
- Thermostaat Jumo
- Thermostaat Qubino
- Thermostaat STI
- Thermostaat Gewiss
- Thermostaat Sinustec
- Thermostaat Rose LM
- Thermostaat MundoControl
- Thermostaat Bearware
- Thermostaat GENERAL Life
- Thermostaat Oreg
- Thermostaat Braeburn
Nieuwste handleidingen voor Thermostaat
18 November 2024
17 November 2024
16 November 2024
16 November 2024
16 November 2024
16 November 2024
16 November 2024
16 November 2024
16 November 2024
16 November 2024