Dometic Pump SW12 Handleiding

Dometic Toilet Pump SW12

Lees hieronder de 📖 handleiding in het Nederlandse voor Dometic Pump SW12 (2 pagina's) in de categorie Toilet. Deze handleiding was nuttig voor 56 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Before installing the pump, remember the following:
1. Vacuum pump can be installed horizontally (either right-side
up A
or upside down B
), or vertically with inlet at bottom C
.
2. The pump can be mounted from 2 to 15 feet from the vacuum
tank. The maximum distance is 15 feet.
3. Install vacuum pump at same level or lower than vacuum tank
outlet. Do not install pump higher than the vacuum tank outlet.
4. The maximum head pressure on the discharge of the pump must
not exceed 6 feet.
Note: Two-toilet systems require a vacuum pump and vacuum tank for each toilet.
It provides the benet of a totally redundant operating toilet in case of failure in one
toilet. Two pumps greatly reduce hose runs and system complexity.
Installing the pump:
1. Make sure the vacuum pump is properly located before proceeding. Place the vacuum pump on the surface
to be mounted. Position as needed. Using a center punch, mark the four slotted holes in the pump feet.
Remove pump.
2. Using a 3/16-inch drill bit, drill the four mounting holes. Use a #14 wood screw to secure pump.
3. The ow direction is indicated on the pump body.
Stainless steel wall mounting bracket is available as optional accessory – P/N 341505.
Wiring the pump:
Wire the S-series pump as shown in the wiring diagram. Use multistranded copper wire. Proper fuse or circuit
breaker size is extremely important for pump and wire protection (see chart above). Overfusing this pump will
result in warranty invalidation.
Electrical schematic also shows installation of optional “night
switch”.
Dimensional
Specications
Electrical
Specications
S Vacuum Pump with
W Motor
Installation Instructions
IMPORTANT NOTICE
VacuFlush
®
sanitation systems must be installed according to
Dometic’s recommended procedures. Do not attempt installation without rst contacting a SeaLand
Product certied dealer or Dometic Corporation.
Model Volts (DC) Avg. Amp Draw GPH Fuse/Breaker Wire Size Weight
SW12 12 6 230 10 amps 12-14 ga. 8 lbs.
SW24 24 3 230 5 amps 14-16 ga. 8 lbs.
A
B C
Dometic Corporation, Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611 USA
1-800-321-9886 • Fax: 330-496-3097
www.Dometic.com
Item Part No. Description
Note: When reassembling pump, tighten screws (included in item 2) to
20±2lbs., or until snug. Over-tightening will cause holes to strip.
S-Series Vacuum Pump
1
2
3-4
5
6
7
8
9
10
11
12
13
14
385640239
385311324
385311224
385311065
385311066
385310644
385310151
385311226
385310242
385230980
385311844
385310076
385311316
385311315
Pump Cover Kit
Pump Top Kit (with screw fasteners)
W Motor Mounting Hardware Kit
W Motor Replacement Kit, 12 VDC
W Motor Replacement Kit, 24 VDC
Eccentric Kit (with fastener screw and bolt)
O-Ring Replacement Kit
Bellows Clamp Kit
Bellows Bushing
Bellows Assembly (includes item 9)
Pump Body
1½” Duckbill Valve Kit (2)
Valve Adapter
Valve Nipple
Dometic warrants, to the original purchaser only, that this vacuum pump, if used for personal, family or household-like purposes, is
free from defects in material and workmanship for a period of one (1) year from the date of purchase.
If this Dometic product is placed in commercial or business use, it will be warranted, to the original purchaser only, to be free of
defects in material and workmanship for a period of ninety (90) days from the date of purchase.
Dometic reserves the right to replace or repair any part of this product that proves, upon inspection by Dometic, to be defective
in material or workmanship. All labor and transportation costs or charges incidental to warranty service are to be borne by the
purchaser-user.
EXCLUSIONS
IN NO EVENT SHALL BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, FOR DAMAGES RESULTING DOMETIC
FROM IMPROPER INSTALLATION, OR FOR DAMAGES CAUSED BY NEGLECT, ABUSE, ALTERATION, OR USE OF UNAUTHORIZED
COMPONENTS. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
ANY PARTICULAR PURPOSE, ARE LIMITED TO A PERIOD OF ONE (1) YEAR FROM DATE OF PURCHASE.
IMPLIED WARRANTIES
No person is authorized to change, add to, or create any warranty or obligation other than that set forth herein.
Implied warranties, including those of merchantability and tness for a particular purpose, are limited to one (1) year from the date
of purchase for products used for personal, family or household-like purposes, and ninety (90) days from the date of purchase for
products placed in commercial or business use.
OTHER RIGHTS
Some states do not allow limitations on the duration of an implied warranty, and some states do not allow exclusions or limitations
regarding incidental or consequential damages; so, the above limitations may not apply to you. This warranty gives you specic legal
rights, and you may have other rights which vary from state to state.
To obtain warranty service, rst contact your local dealer from whom you purchased this product.
Manufacturers Limited Warranty
REVISION B
Form No. 600344820 9/18
©2018 Dometic Corporation


Product specificaties

Merk: Dometic
Categorie: Toilet
Model: Pump SW12

Heb je hulp nodig?

Als je hulp nodig hebt met Dometic Pump SW12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Toilet Dometic

Handleiding Toilet

Nieuwste handleidingen voor Toilet