doepfer System A - 100 Dual Trigger Modifier A-165
1
1. Introduction
Module A-165 (Dual Trigger Modifier) contains two
separate trigger modifiers, to use with logical / digital
levels (Gate, Clock, Trigger). Each half of the module
enables signals generated by the A-100 to communi-
cate with other instruments (such as an external se-
quencer), or is simply used where you want to reverse
a trigger polarity.
Whatever signal is patched into the input is inverted by
the module, and fed out of the Inv. Out (inverted
output) socket.
At the same time, a trigger signal of roughly 50 ms is
generated every time an edge of the trigger pulse is
sensed (negative as well as positive). This trigger
signal is available at the +/- output.
Two LEDs act as indicators showing the level of signal
available at the two outputs.
A-165
TRIG. MODIF.
In
Inv.
Out
In
+/-
Out
In
Inv.
Out
In
+/-
Out
A-165 Dual Trigger Modifier System A - 100 doepfer
2
2. Overview Indicators
1 LED : Status indicator for the inverted trig-
ger signal at output §
2 LED : Status indicator for the trigger pulse
generated, and available at output $
In / Outputs
! In : Input for trigger signal
" ! In : ditto, linked to input
§ Inv. Out : Output for the inverted trigger signal
$ +/- Out : Output for the trigger pulses genera-
ted by the A-165
A-165
In
TRIG. MODIF.
In
Inv.
Out
+/-
Out
In
In
Inv.
Out
+/-
Out
doepfer System A - 100 Dual Trigger Modifier A-165
3
3. Indicators
1 LED
This LED is the status indicator for the inverted
trigger signal at output §.
2 LED
This LED is the status indicator for the trigger
pulses the A-165 generates, available at output $.
4. In / outputs
! In • " In
Sockets ! and " are the interconnected Inputs to the
A-165. This is where the trigger signal to be modified
is patched in.
P In practice, the original and inverted trigger
signal are often both needed at the same
time, so it’s possible to use these two inputs
as a mini-multiple - using one of them to
send the original trigger to another module.
§ Inv. Out
The inverted trigger signal is available at output §
(see Fig. 1).
$ +/- Out
Output $ carries the trigger signals generated by both
the leading and falling edges of the original trigger
signal (pulse length: approx. 50 ms). See Fig. 1.
Fig. 1: How the A-165’s outputs relate to the input.
w
+/-
Out
Inv.
Out
In


Product specificaties

Merk: Doepfer
Categorie: Niet gecategoriseerd
Model: A-165

Heb je hulp nodig?

Als je hulp nodig hebt met Doepfer A-165 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Doepfer

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024