A-135-2 Quad VCA / Voltage Controlled Mixer
Position and function of the jumpers and connectors Board A
The pin headers JP4, JP5, JP6 and JP7 are used to determine the control voltages for the VCAs 2-4:
JP4: VCA2 control
jumper in upper position Æ VCA2 is controlled by CV2 (factory setting)
jumper in lower position Æ VCA2 is controlled by CV1 (in this case CV2 does not affect VCA2)
JP5: VCA3 control
jumper in upper position Æ VCA3 is controlled by CV3 (factory setting)
jumper in lower position Æ VCA3 is controlled by CV1 (in this case CV3 does not affect VCA3)
JP6: VCA4 control
jumper in upper position Æ VCA4 is controlled by CV4 (factory setting)
jumper in lower position Æ VCA4 is controlled by CV1 (in this case CV4 does not affect VCA3)
JP7: alternative VCA4 control
jumper installed Æ VCA4 is controlled by CV2 (used for "Stereo" mode)
In this case the jumper on JP6 has to be removed !
JP4: VCA2 control
Bus connector
(colored stripe left)
JP5: VCA3 control
JP6: VCA4 control
JP7: alternative
VCA4 control
Applications of the different jumper settings
Remark: under all conditions VCA1 is controlled by control unit 1.
This is the standard configuration:
• JP4, JP5 and JP6 are installed in the upper position
• no jumper is installed on JP7
In this case each VCA has it's own control unit.
"Stereo" configuration:
• JP4 is installed in the upper position (VCA2 is controlled by CV2)
• JP5 is installed in the lower position (VCA3 is controlled by CV1)
• JP6 is removed
• JP7 is installed (VCA4 is controlled by CV2)
In this configuration VCA1 and VCA3 are controlled by CV1, VCA2 and VCA4 are controlled by CV2.
The control units 3 and 4 have no meaning in this confuguration.
Special configuration (all four VCAs are controlled by CV1):
• JP4, JP5 and JP6 are installed in the lower position
• no jumper is installed on JP7
In this configuration all four VCAs are controlled by CV1. The control units 2, 3 and 4 have no meaning in this
application. This configuration is used when four different audio or control signals have to be controlled
simultaneously (e.g the level of four VCOs, four LFOs, four envelope generators and so on). It's the same
function as the obsolete quad VCA module A-132-2.
A-135-2 Quad VCA / Voltage Controlled Mixer
Position and function of the jumpers and connectors Board B
The pin headers JP8, JP9 and JP10 may be used for the normalling of the input signals.
JP8:
when installed audio in 1 is normalled to the switching contact of the audio in 2 socket
JP9:
when installed audio in 2 is normalled to the switching contact of the audio in 3 socket
JP10:
when installed audio in 3 is normalled to the switching contact of the audio in 4 socket
Application:
Distributing an audio or control signal to four different destinations with different manually and/or voltage
controlled levels.
Factory setting: jumpers are not installed !
JP10: normalling o
f
audio in 3 Æ audio in 4
JP8: normalling of
audio in 1 Æ audio in 2
JP9: normalling o
f
audio in 2 Æ audio in 3


Product specificaties

Merk: Doepfer
Categorie: Niet gecategoriseerd
Model: A-135-2v

Heb je hulp nodig?

Als je hulp nodig hebt met Doepfer A-135-2v stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Doepfer

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024