Dimplex WST12 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex WST12 (12 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 47 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
The product complies with the European Safety Standards EN13240 for Room heaters red by solid fuel.
08/51120/0 - Issue 0
UK
Westcott 12kW Stove
1
23
Table 1 - Dimensions A B C D E F G H J K L
Westcott 12kW 688 640 652 326 670 104 50 356 113 538 150
Note: All Dimensions in mm. Dimensions stated may be subject to a slight ± variation. ( 25.4mm = 1”)
Table 2. - Technical Specication Westcott 12kW
Nominal heat output Wood kW 12.1
Solid Fuel (Ancit) kW 12.2
Efciency Wood % 73.1
Solid Fuel (Ancit) % 71.1
CO Emission (@13% O )2
Wood % 0.68
Solid Fuel (Ancit) % 0.09
Flue Gas Temp °C 396
Flue Gas Mass Flow Wood g/s 8.0
Solid Fuel (Ancit) g/s 10.0
Refuel Period hr 1
Safe Distance to Combustibles Sides mm 600
Rear mm 600
Flue Outlet Size mm 150
Product Weight kg 134
F
G
K
J
H
A
B
C
D
E
L (Dia)
1
2
3
X
A
B
C
4
x 4
A
150
150
150
300 CONSTRUCTIONAL HEARTH
NON COMBUSTIBLE
125mm THICK MINIMUM
H
MIN
150mm
X
X
T
T
MIN
150mm
MIN
125mm
See Table 3
Solid, non-combustible
material e.g. masonary
or concrete
1
2
x2
4 5
6
8 9
7
Table 3 Position of Hearth & Appliance In Relation to walls Wall Dimensions
Hearth distance from wall ‘X’ Appliance distance from wall Min Wall Thickness ‘T’ Min Wall height ‘H’
0mm 0 - 50mm 200mm Height of appliance +300mm
or 1200mm from hearth
(whichever is greater)
0mm 51 - 300mm 75mm
0 - 150mm +150mm 75mm
+150mm +300mm No Minimum Requirement
45°
Max
150 Max
Seal with fire
proof lagging


Product specificaties

Merk: Dimplex
Categorie: Fornuis
Model: WST12

Heb je hulp nodig?

Als je hulp nodig hebt met Dimplex WST12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis Dimplex

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis