Dimplex BLM5SE Handleiding

Dimplex Fornuis BLM5SE

Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex BLM5SE (12 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 16 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
The product complies with the European Safety Standards EN13240 for room heaters red by solid fuel.
08/52386/0 - Issue 3
03 Nov 2015
Please hand these instructions to the stove user when installation is complete.
Leave the system ready for operation and instruct the user in the correct use of the
appliance and operation of controls.
Installation should only be carried out by a suitably qualied installer.
Dimplex recommend using an installer who is registered with HETAS (UK) or with INFO
(Republic of Ireland). Installation must comply with all current Building Regulations.
Bellingham 5kW
Multi-fuel stove
(BLM5SE)
UK IE
Max
+_+
Solid Fuel
Burning
Wood
Burning
Max
Boost/
Refuel
Min
1
Table 1 - Dimensions A B C D E F G H I J K
Bellingham 5kw 596 466 35 233 120 368 70 140 195 465 127
Note: All Dimensions in mm. Dimensions stated may be subject to a slight ± variation. ( 25.4mm = 1”)
2
A
B
D
E
C
J
H
F
K (Dia)
I
G
x 4
A3
- 2 -
Table 2 - Technical Specication Bellingham 5kw (BLM5SE)
Wood Solid Fuel (Ancit)
Nominal heat output kW 5.0 4.9
Efciency 84.8 85.0%
CO Emission (@13% O ) %20.34 0.33
Flue Gas Temp °C 210 215
Flue Gas Mass Flow g/s 3.3 2.9
Refuel Period hr 1
Safe Distance to Combustibles mm Sides 500mm
Rear 250mm
Flue Outlet Size mm / inch 127 / 5
Product Weight kg 71.8
Additional Room Ventillation Required see table 4cm²
4 5
6 7
Table 3 - Position of Hearth & Appliance from adjacent walls
Hearth distance ‘X’ from wall Appliance distance from walls Min Wall Thickness ‘T’ Min Wall height ‘H’
0mm 0 - 50mm 200mm Height of appliance +300mm
or 1200mm from hearth
(whichever is greater)
0mm 51 - 150mm 75mm
0 - 150mm 150 - 300mm 75mm
+150mm +300mm No Minimum Requirement
H
MIN
150mm
X
X
T
T
MIN
150mm
MIN
125mm
See Table 3
Solid, non-combustible
material e.g. masonary
or concrete
300mm
X
FREESTANDING ON
NON COMBUSTIBLE HEARTH
MIN 12mm THICK
MIN 840mm
MIN 840mm
150
150
150
300
45°
Max
150mm Max
Fire proof seal
or fire cement
30mm Min
- 3 -