Dimplex FX20V Handleiding
Lees hieronder de π handleiding in het Nederlandse voor Dimplex FX20V (3 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/3
ξ
ξ
Contactξ ξDetails
ξ
Pleaseξnoteξthat some contactξ ξofξtheξ ξdetails onξ ξ
thisξPDFξdocumentξmayξnotξbeξ ξcurrent.
ξ
Pleaseξuseξ ξ ξthe following detailsξifξyouξneedξtoξ
contactξus:ξ
ξ
Telephone:ξ0844 879ξ ξ3588ξ
Email:ξcustomer.services@gdcgroup.co.ukξ
ξ
ξ
The wideξcustomer alsoξsupportξsection websiteξofξourξ ξ ξfeaturesξ ξaξ
rangeξof ofξinformationξwhichξmayξbeξ ξuse availableξtoξyouξandξisξ ξ
24 aξhoursξ ξday.ξItξincludes:ξ
ξ
β’ Operatingξ ξ ξ ξand installation instructions
β’ Easyξ ξ ξ ξ ξ ξ ξ ξβHow to useβ guides for storage heaters
β’ Serviceξ ξ ξand repairs
β’ Whereξtoξbuyξourξproductsξ
β’ Literatureξ ξdownloads
β’ Heatingξ ξ ξrequirement calculator
ξ
ξξξξξ ξβξVisit www.dimplex.co.uk/supportξ
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number β
WEE/GE0057TS
Paper from sustainable sources
Downflow Fan Heater
Model : FX 20V
Installation and Operating Instructions
Dimensions
(millimetres)
Model(s) Specification
FX 20V (High Level) 1/2kw + Adjustable Thermostat (internal by installer)
Fig. 1
(IP22)
IMPORTANT SAFETY ADVICE
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
DO NOT COVER THE APPLIANCE or place material or garments
on it, or obstruct the air circulation around this appliance, for
example with curtains or furniture, as this could cause
overheating and a fire risk.
DO NOT PLACE AEROSOLS OR OTHER CONTAINERS
SUSCEPTIBLE TO HEAT IN THE DIRECT AIRFLOW FROM THE UNIT.
THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A
FIXED SOCKET OUTLET.
WARNING: Do not operate the heater with the top cover removed.
The appliance is not intended for use by children or other persons
without assistance or supervision if their physical, sensory or
mental capabilities prevent them from using it safely. Children
should be supervised to ensure that they do not play with the
appliance.
WARNING β DISCONNECT THE HEATER FROM THE ELECTRICITY
SUPPLY BEFORE UNDERTAKING SERVICE OR REPAIR.
WARNING β If the appliance is fitted in a bathroom, a cable outlet
will be necessary with the supply to the unit controlled by a
double pole switch. The switch if inside the bathroom should be
pull cord operated and if outside should be adjacent to the
entrance door. The appliance must be mounted so that no part of
it can be touched by any person using bath or shower.
THIS HEATER MUST NOT BE OPERATED WITHOUT THE COVER
CORRECTLY IN POSITION.
Warning : In order to avoid a hazard due to inadvertent resetting of
the thermal cutout, this appliance must not be supplied through an
external switching device, such as a timer, or connected to a
circuit that is regularly switched on and off by the utility.
General
The heater has a loading of 2KW. It is designed for permanent wall mounting
and is suitable for operation on A.C. electricity supply having the same
voltage as shown on the rating label.
The heater is fitted with an internally mounted selector switch which on
installation of the heater allows a choice of 1kW or 2kW output to suit the
dimensions of the room to be heated.
In rooms of less than 9 β 11 cubic m. (350 - 400 cubic ft.) 1kW output should
be selected, otherwise nuisance tripping of the thermal overload cut-out
may occur.
NOTE : THE SWITCH HAS BEEN FACTORY SET FOR 1kW OPERATION.
IF ADDITIONAL OUTPUT IS REQUIRED, 2kW CAN BE SELECTED ON
INSTALLATION.
SUPPLY CABLE IS NOT SUPPLIED WITH THIS APPLIANCE AND IT
SHOULD THEREFORE BE INSTALLED BY A COMPETENT ELECTRICIAN
IN ACCORDANCE WITH THE LATEST IEE REGULATIONS.
08/15981/6 Issue 6
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Controls
The cut-out is a safety device which switches off the heater and fan if for
any reason the appliance overheats - see βSafetyβ.
The thermal fuse link is provided as an added safety feature, and operates
to open circuit if there is abnormal overheating within the appliance. The
operation of these safety devices is described under βSafetyβ.
The pull cord switch operates the ON/OFF switch. (An indicator light
illuminates to show when the heater is ON and does not illuminate when
the heater is OFF) .
The heater is fitted with an adjustable thermostat, which has three different
settings : 1. - Low, 2. - Medium, 3 - High. This gives you an approximate
room temperature range of 18Β°C - 32Β°C depending on room size. If internal
switch is set to 2kW, the temperature switches to half heat when the room
warms up. Full heat will be switched on automatically when the room
temperature falls. This can be adjusted by installer, by removing top cover.
The thermostat will only function when 2KW is selected. The thermostat
has been factory set on β2β (Medium).
To adjust the thermostat setting or reset selector switch first remove the top
cover, then adjust thermostat to required setting, or reset selector switch to
1kW or 2kW as required, then refit top cover. Do not operate the unit with
the top cover removed.
Safety
Cut-Out
For your safety, this appliance is fitted with a thermal cut-out. In the event
that the product overheats, the cut-out switches the heater off automatically.
To bring the heater back into operation, remove the cause of overheating,
then turn off the electrical supply to the heater for a few minutes.
When the heater has cooled sufficiently reconnect and switch on the heater.
Fuse Link
A thermal fuse link is provided as an added safety feature. If the fuse link
operates and opens circuit it is the result of abnormal overheating within
the appliance, and servicing of the appliance by a competent service
engineer will be required in order to ensure the future safe operation of the
heater. Dimplex Customer Services should be contacted (see βAfter Sales
Serviceβ for details), who will arrange the replacement of any faulty parts
and the fitting of a new fuse link.
Installation
WARNING: Minimum clearences must be adhered to when mounting
the heater.
Before undertaking installation work, ensure the electricity supply is
disconnected from any relevant fixed wiring. Supply cable is not supplied
with this appliance and it should therefore be installed by a competent
electrician in accordance with the latest IEE wiring regulations.
The supply circuit must be adequate for the input of the appliance and
must be protected with a 13A fuse.
A suitable termination to the fixed wiring of the premises must be provided
adjacent to the final position of the appliance through a double pole
switch having a contact separation of at least 3mm in all poles.
250 229
242
109300
MIN
1800
600
MIN
MIN
MIN
floor
ceiling
shelf
Fig. 2
Fig. 4
Installation Procedure
It is essential to observe minimum wall mounting clearances - see Fig. 1.
The appliance should be fitted horizontally, with the cable entry at the top
and grille at the bottom. It must be mounted not less than 1800mm above
the floor with a clearance of at least 600mm to any shelf or projecting
surface below the heater and not less than 300mm below the ceiling or
other projecting surface. It must also be not less than 250mm from an
adjacent projecting surface. For most effective heating performance, the
heater should be mounted at the minimum height : i.e. 1800mm above
the floor.
Care must be taken to ensure that when in use, the air stream is not
obstructed by a high shelf or cabinet.
The appliance is secured to the wall with three screws, two through
keyhole slots and one through a centrally positioned lower hole to hold
the appliance firmly in position (see Fig. 2).
1. Remove the top cover from the appliance by removing the two
screws securing the top cover and hinging it back.
2. Mark the position of the keyhole slots on the wall and drill and plug
for the two suitable screws.
3. Partially insert the two screws, then hang the appliance on these
screws and mark the position of the lower centrally positioned screw.
4. Remove the appliance and drill and plug for the third screw.
5. Remount the appliance on the wall, ensure that it is horizontal and
fix in position by tightening all three screws.
6. Feed the supply cord or wires through the inlet at the top rear of the
appliance leaving sufficient free length to connect to the terminal
block.
7. Make electrical connections to the terminal block ensuring that the
live connection is made to the terminal marked βLβ and the neutral
connection to the terminal marked βNβ (see Fig. 2 exploded view).
8. Operate the selector switch to provide either 1kW or 2kW output.
9. Replace the top cover and screws.
The appliance is now ready for use and the electricity supply can be
reinstated.
FX20V Controls
The heater is fitted with a pull cord
operated ON/OFF switch, a thermostat, a
cut-out, and a thermal fuse link.The
heater has an internal adjustable
thermostat which can be adjusted by
installer (i.e. the top cover has to be
removed), see Fig. 4 for controls details
with cover removed. Temp. range 18Β°C -
32Β°C.
Cleaning and User Maintenance
WARNING: BEFORE UNDERTAKING CLEANING OR MAINTENANCE WORK
ON THE APPLIANCE DISCONNECT THE ELECTRICITY SUPPLY BY
SWITCHING OFF AT THE ADJACENT DOUBLE POLE SWITCH.
The outside can be cleaned by wiping it over with a soft damp cloth and
then dried. Do not use abrasive cleaning powders or furniture polish as this
can damage the surface finish.
Ensure that dust or fluff does not accumulate inside the heater as this could
lead to overheating of the element. Use a vacuum cleaner to remove any
fluff which does accumulate.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should not be
disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for
recycling advice in your country.
After Sales Service
If this product appears damaged when first received or does not
function correctly contact us by e-mail aftersales@dimplex.co.uk or
ring 0844 879 35 88 and we will be able to help. For ROI please phone
018424833.
Do Not Return the product in the first instance as this may delay us
providing you with a satisfactory service.
ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY.
Your product is guaranteed for two years from the date of purchase.
Within this period, we undertake to repair this product free of charge
provided it has been installed and operated in accordance with these
instructions.
Should you require assistance with this product please go to
www.dimplex.co.uk and click on βCustomer Supportβ or e-mail us at
aftersales@dimplex.co.uk
Alternatively ring our contact centre on 0844 879 35 88 (UK only). This is
a Lo-call no. from a BT landline - other providers including mobile
phones may charge you more. For ROI please phone 01 842 4833.
To assist you, we will need the following information: model number and
serial no (these can be found on the product), nature of the fault and date
of purchase. Please retain your receipt as proof of purchase. Your
rights under this guarantee are additional to your statutory rights, which
in turn are not affected by this guarantee.
Spares can be purchased on line, go to www.dimplex.co.uk/outlet_store
M
Fig. 3 - FX20V Wiring Diagram
L
N
selector
switch
internal adjustable
thermostat knob
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014,
EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
Dimplex UK Ltd.
Millbrook House
Grange Drive
Hedge End
Southampton
Hampshire. SO30 2DF
www.dimplex.co.uk
Republic of Ireland Tel. 01 8424833
[c] Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex UK Limited.
Product specificaties
Merk: | Dimplex |
Categorie: | Heater |
Model: | FX20V |
Kleur van het product: | Wit |
Warmtebron: | Electrisch |
Gewicht: | 1100 g |
Breedte: | 229 mm |
Diepte: | 109 mm |
Hoogte: | 242 mm |
Soort: | Radiator/ventilator |
Vermogen: | 2000 W |
Aan/uitschakelaar: | Ja |
Indicatielampje: | Ja |
Geschikt voor: | Binnen |
Instelbare thermostaat: | Nee |
Ophangsysteem voor aan de muur: | Ja |
Verwarmingsvermogen: | 2000 W |
Plaatsingsopties: | Muur |
Geschikt voor de badkamer: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Dimplex FX20V stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Heater Dimplex
15 November 2024
15 November 2024
15 November 2024
25 Maart 2024
25 Maart 2024
25 Maart 2024
26 Februari 2024
26 Februari 2024
26 Februari 2024
26 Augustus 2023
Handleiding Heater
- Heater Electrolux
- Heater Bosch
- Heater Philips
- Heater HP
- Heater Candy
- Heater Delonghi
- Heater Xiaomi
- Heater AEG
- Heater Bauknecht
- Heater BEKO
- Heater DeWalt
- Heater Honeywell
- Heater Quigg
- Heater Tefal
- Heater Unold
- Heater Zanussi
- Heater Zibro
- Heater Adler
- Heater Afk
- Heater AKO
- Heater Alpina
- Heater Ambiano
- Heater Argo
- Heater Ariete
- Heater Arnold Rak
- Heater Astralpool
- Heater Atika
- Heater Barbecook
- Heater Bartscher
- Heater Basetech
- Heater Beper
- Heater Bestron
- Heater Bestway
- Heater Beurer
- Heater Bionaire
- Heater Blaupunkt
- Heater Blaze
- Heater Blumfeldt
- Heater Bomann
- Heater Boretti
- Heater Brandson
- Heater Brixton
- Heater Burley
- Heater Danfoss
- Heater Defy
- Heater Dometic
- Heater Domo
- Heater Dovre
- Heater Duro Pro
- Heater Duronic
- Heater Duux
- Heater Dyson
- Heater Easymaxx
- Heater EBERLE
- Heater Ecoteck
- Heater Eden
- Heater Einhell
- Heater Elro
- Heater Emerio
- Heater Emga
- Heater Enders
- Heater ETA
- Heater Etherma
- Heater Eureka
- Heater Eurom
- Heater Eurotronic
- Heater Evolar
- Heater EWT
- Heater Extraflame
- Heater Fagor
- Heater Ferm
- Heater Ferroli
- Heater G3 Ferrari
- Heater Global
- Heater Gorenje
- Heater Grandhall
- Heater GRE
- Heater Gude
- Heater Gutfels
- Heater H.Koenig
- Heater Hama
- Heater Harvia
- Heater Haverland
- Heater Hayward
- Heater Heatstrip
- Heater Hema
- Heater Hendi
- Heater HQ
- Heater Hyundai
- Heater Innoliving
- Heater Invicta
- Heater Kalorik
- Heater Kambrook
- Heater Kenmore
- Heater Kent
- Heater Klarstein
- Heater Koenic
- Heater Kogan
- Heater Konig
- Heater Korona
- Heater La Nordica
- Heater Lavorwash
- Heater Lervia
- Heater Livington
- Heater Livoo
- Heater Logik
- Heater Lynx
- Heater Maestro
- Heater Maginon
- Heater Master
- Heater Maxwell
- Heater Maxxmee
- Heater Medisana
- Heater Melissa
- Heater Mesko
- Heater Mestic
- Heater Midea
- Heater Mill
- Heater Milwaukee
- Heater MPM
- Heater Napoleon
- Heater Nedis
- Heater Nestor Martin
- Heater Nobo
- Heater Nordic Fire
- Heater Parkside
- Heater Pelgrim
- Heater Perel
- Heater Philco
- Heater Piazzetta
- Heater Plieger
- Heater Powerfix
- Heater Prem-i-air
- Heater Primo
- Heater Princess
- Heater Profile
- Heater Proline
- Heater Qlima
- Heater Reer
- Heater REMKO
- Heater Rommelsbacher
- Heater Rotel
- Heater Rowenta
- Heater Rowi
- Heater Royal Sovereign
- Heater Russell Hobbs
- Heater Ryobi
- Heater Scheppach
- Heater Sencor
- Heater Severin
- Heater Silvercrest
- Heater Sogo
- Heater Solac
- Heater Solamagic
- Heater Solis
- Heater Sonnenkonig
- Heater SPT
- Heater Stadler Form
- Heater Stanley
- Heater Starlyf
- Heater Steba
- Heater Stiebel Eltron
- Heater Sunbeam
- Heater SunRed
- Heater Suntec
- Heater Superior
- Heater Swan
- Heater Sygonix
- Heater Taurus
- Heater Team
- Heater Tectro
- Heater Termozeta
- Heater Thomson
- Heater Topcraft
- Heater Toyotomi
- Heater Tristar
- Heater Trotec
- Heater Truma
- Heater Trumatic
- Heater Ufesa
- Heater United
- Heater Vasco
- Heater Velleman
- Heater Vitek
- Heater Vivax
- Heater Vonroc
- Heater Vornado
- Heater Wamsler
- Heater Wanders
- Heater Weishaupt
- Heater Westfalia
- Heater Zehnder
- Heater Zelmer
- Heater Zibro Kamin
- Heater Zodiac
- Heater Jaga
- Heater Jata
- Heater Jocel
- Heater Jotul
- Heater Just Fire
- Heater OK
- Heater Olimpia Splendid
- Heater Olympia
- Heater OneConcept
- Heater Orion
- Heater Becken
- Heater Black And Decker
- Heater Camry
- Heater Caso
- Heater Clatronic
- Heater Concept
- Heater Cuisinart
- Heater ECG
- Heater Essentiel B
- Heater Guzzanti
- Heater Heinner
- Heater Imetec
- Heater Izzy
- Heater Mellerware
- Heater Optimum
- Heater Orbegozo
- Heater Scarlett
- Heater Sinbo
- Heater Trisa
- Heater Vox
- Heater Wilfa
- Heater Anslut
- Heater Fenix
- Heater Kunft
- Heater Soler And Palau
- Heater Fluval
- Heater SuperFish
- Heater CorberΓ³
- Heater Danby
- Heater EMOS
- Heater Infiniton
- Heater King
- Heater Conceptronic
- Heater Nevir
- Heater Svan
- Heater Cotech
- Heater Ardes
- Heater Cresta
- Heater Eldom
- Heater Grunkel
- Heater Teesa
- Heater Alpatec
- Heater Heylo
- Heater Prime3
- Heater Haeger
- Heater SereneLife
- Heater Brentwood
- Heater Gasmate
- Heater DCG
- Heater Malmbergs
- Heater Sun Joe
- Heater Mora
- Heater Calor
- Heater Eurolite
- Heater Broan
- Heater Dedra
- Heater CasaFan
- Heater Martec
- Heater Zephir
- Heater Lenoxx
- Heater Hartig And Helling
- Heater Bimar
- Heater Crane
- Heater Lasko
- Heater Vasner
- Heater Creda
- Heater Otsein-Hoover
- Heater MSW
- Heater Chauvet
- Heater Mr. Heater
- Heater SHX
- Heater Tesy
- Heater Orava
- Heater Signature
- Heater CaterChef
- Heater SPC
- Heater Cecotec
- Heater Baxi
- Heater Thermex
- Heater Flama
- Heater Fantini Cosmi
- Heater Vemer
- Heater Rinnai
- Heater Noirot
- Heater WAGAN
- Heater LifeSmart
- Heater Carson
- Heater FIAP
- Heater Perfect Aire
- Heater Ausclimate
- Heater Masport
- Heater Real Flame
- Heater Air King
- Heater Dantherm
- Heater Noveen
- Heater Nectre
- Heater Argoclima
- Heater Cadel
- Heater Heller
- Heater Waldbeck
- Heater PAX
- Heater Clean Air Optima
- Heater AENO
- Heater Osburn
- Heater Euromac
- Heater Everdure
- Heater TAIDEN
- Heater Veito
- Heater Haas+Sohn
- Heater Uniprodo
- Heater Tecno Air System
- Heater Adax
- Heater NewAir
- Heater Escea
- Heater Braemar
- Heater Bromic Heating
- Heater Jindara
- Heater Neo
- Heater Hatco
- Heater JANDY
- Heater Aerian
- Heater IXL
- Heater XPower
- Heater True North
- Heater WestBend
- Heater Hortus
- Heater Quadra-Fire
- Heater Stenda
- Heater VIESTA
- Heater Apricus
- Heater Heatsome
- Heater Brivis
- Heater Hubbell
- Heater HeatStar
- Heater Pacific Energy
- Heater Dri Eaz
- Heater Regency
- Heater NEO Tools
- Heater Monzana
- Heater Invroheat
- Heater Kaden
- Heater Jarden
- Heater GoldAir
- Heater Ouellet
- Heater AccuLux
- Heater Ravanson
- Heater Gossmann
- Heater Wulfe
- Heater Create
- Heater Herschel
- Heater Casaya
- Heater HyCell
- Heater TURBRO
- Heater Radialight
- Heater Sunheat
- Heater Heidenfeld
- Heater Hcalory
- Heater Neopower
- Heater Arlec
- Heater Guardian
- Heater Big Ass Fans
- Heater Pureheat
- Heater EvoHeat
- Heater DCS
- Heater Bromic
- Heater Omega Altise
- Heater Scandia
- Heater Mirpol
- Heater Contura
- Heater Alkari
- Heater Longvie
- Heater Blue Rhino
- Heater Rheem
- Heater Ionmax
- Heater Airo
- Heater Mission Air
- Heater Fire Sense
- Heater InfraNomic
- Heater Heat Storm
- Heater Excelair
- Heater Heatscope
- Heater Heat1
- Heater Thermotec
- Heater Kemlan
- Heater Yellow Garden Line
- Heater AustWood
- Heater Yamazen
- Heater Infratech
- Heater TANSUN
- Heater Universal Blue
Nieuwste handleidingen voor Heater
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
18 December 2024
16 December 2024
16 December 2024
14 December 2024