Dimplex CXD Ceramic Radiant Heaters
Model(s) : CXD2000H & CXD2000V
(IPX4)
IMPORTANT SAFETY ADVICE
Because the Dimplex Ceramic Radiant
Heater contains no moving parts
little maintenance is required. Before
undertaking any maintenance work on the
heater due attention must be paid to the
following:
This heater is designed to be horizontally
wall mounted only, it must not be ceiling
mounted.
Always ensure a safe mounting height, at or
above a minimum height of 1.8 metres from
ground level, so that the heater can not be
touched when in operation.
The heater must be wall mounted level ± 5º
to the horizontal.
Do not locate the heater immediately
above or below a xed socket outlet or
connection box.
WARNING:
Do not use this heater in the immediate
surroundings of a bath, a shower or a
swimming pool.
This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory or
mental capabilities or lack of experience
or knowledge if they have been given
supervision or instruction concerning the
use of the appliance in a safe way and
understand the hazards involved. Children
shall not play with the appliance. Cleaning
and user maintenance shall not be made by
children without supervision.
Children of less than 3 years should be
kept away unless continuously supervised.
Children aged from 3 years and less than 8
years shall only switch on/o the appliance
provided that it has been placed or installed
in its intended normal operating position
and they have been given supervision
or instruction concerning the use of the
appliance in a safe way and understand
the hazards involved. Children aged from 3
years and less than 8 years shall not plug in,
regulate and clean the appliance or perform
user maintenance.
CAUTION:
Some parts of this product can become
very hot and cause burns. Particular
attention has to be given where children
and vulnerable people are present.
Always disconnect the heater from the
electricity supply before attempting to
work on or near it.
Always ensure a safe means of access using
an access tower or properly supported
ladder.
Do not cover the heater.
Keep combustible materials away from the
heater.
Do not position patio furniture, sunshades,
awnings and other combustible materials
too close to the heater.
Do not use heater if the elements are
broken - as injury may occur.
Allow adequate time (minimum of 30
mins.) for the elements and body casing
to cool before attempting to work on the
heater .
Wiring between the heater and the spur
outlet or isolation switch must be in a heat
resisting cable (e.g. polychloroprene).
NOTE:
Provide su cient slack to the cable to
allow for angular adjustment of the body.
The supply cord should be regularly
examined for signs of damage and the
appliance is not to be used if the cord is
damaged.
The supply circuit to the heater must
incorporate a double pole isolating switch
having a contact separation of at least
3mm in all poles.
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
08/19367/0 Issue 8
2
1
1
Fig. 4
Fig. 2 Fig. 3
CXD2000V
CXD2000H
Fig. 1
C
B
A
E
D
Electrical
Installation
Cleaning and User Maintenance
WARNING: Before undertaking this task ensure the heater is
disconnected from the electric supply and left to cool
for a minimum of 30 minutes.
WARNING: The installation of this appliance should be carried out by
a competent electrician and be in accordance with the
current IEE wiring regulations and any local or insurance
regulations.
WARNING: Before undertaking cleaning or maintenance work on the
appliance, disconnect the electricity supply.
NOTE: Always ensure the cable gland nut is tightened.
1. The heater should be taken o the wall.
2. Remove the screws (A) and (B) which hold the control box on the
back of the heater.
3. This will allow access to the elements. Remove the retaining clips
and spring clips (C) to loosen the elements.
4. Disconnect the elements from their terminal blocks.
5. Remove the screws (D) which hold the back panel.
6. Remove the splash brackets (E) on the elements.
7. Bend the bars on the guard as indicated in Fig. 3 to remove it.
8. The old element should drop out through the front of the heater,
reverse the process when replacing with the new element.
The CXD2000H & CXD2000V are designed for use on a 230-240V AC
single phase supply.
An all-pole isolating switch with a minimum separation of 3mm in each
pole must be tted to facilitate isolation. This switch must either be
positioned inside a building or have an IP rating against water ingress
suitable for external installation.
The appliance must be supplied through a residual current device (RCD)
having a rated residual operating current not exceeding 30mA.
The appliance must be connected to a socket-outlet having an earthing
contact.
We recommend that a cable with a minimum speci cation of H07RN-F
polychloroprene sheathed or similar be used with a minimum temperature
rating of 90°C.
A 3 Core Cable of 2.5mmCSA MINIMUM must be used in the cable gland.
Your Dimplex Ceramic Radiant Heater uses ceramic elements which
produce a high proportion of their output in the long-wave infra-red.
This provides a high comfort factor – similar to the natural energy from
the sun.
While the CXD range of heaters are designed to provide local radiant
heating in draughty and / or hard to heat areas, they are not intended
to provide a complete solution to space heating and thermal comfort.
Heaters are supplied with an integral wall bracket which may be fi xed
through the mounting holes to any suitable structure. The bracket allows
the heater to be inclined at the required angle. The recommended xing
height to the centre line of the bracket is 2.0m from ground level - see
Fig. 2.
The integral wall xing bracket may be removed by fully unscrewing to
facilitate its fi xing.
The siting of the heater(s) should be such as to allow an even and
uninterrupted distribution of radiation to the area(s) to be heated.
Heaters are most e ective when the beam angle is inclined down at an
angle of between 30º to 45º to the vertical - see Fig. 2.
When deciding upon the best location, consideration must be given to
the following requirements:
a. Avoid structures which might vibrate e.g. crane gantries. These could
adversely a ect element life.
b. Comfort and safety could be compromised unless the heater is
mounted at or above 1.8m from ground level.
c. Allow a minimum of 500mm minimum clearance between the top
of the heater and any horizontal surface - see Fig. 1.
Since the appliance contains no moving parts little maintenance is required
beyond cleaning and element replacement. It is however essential that
the heater is not operated with an accumulation of dust or dirt on the
element, as this can cause a build up of heat and eventual damage. For
this reason the heater must be inspected regularly, depending upon
conditions and at least at yearly intervals.
Allow adequate time for the element and body casing to cool before
attempting to work on the heater - a minimum time of 30 minutes is
recommended
General Element Replacement (see Fig. 4)