VP700/1000/1200/1600ELCD
User’s Manual
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate
your UPS.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection.
DO NOT plug the UPS into an outlet that is not grounded. If you need to -energize this equipment, turn o and de
unplug the UPS.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower does not sell products
for life support or medical applications. use in any circumstance that would aect the operation and safety DO NOT
of life support equipment, medical applications, or patient care.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is
disconnected.
CAUTION! To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor area,
free of conductive contaminants. (Please see specications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover There are no user serviceable parts .
inside.
CAUTION! To avoid electrical shock, turn o the unit and unplug it from the AC power source before installing a
computer component.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of re, do not use with or near
aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause the
machine to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of re or electric shock, do not use the
unit on any transportation such as airplanes or ships. The eect of shock or vibration caused during transit and the
damp environment can cause the unit to short out.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following:
(1) UPS Unit 1; (2) USB Cable User Manual 1; Power Cord 1 x x 1; (3) x (4) x
OVERVIEW
The V 00/1000/1200/1600ELCDP7 provides automatic voltage regulation for inconsistent utility power, and provides
battery backup during power outages. The V 00/1000/1200/1600ELCDP7 ensures consistent power to your
computer system and its included software will automatically save your open les and shut down your computer
system during a utility power loss.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral equipment does
not exceed the VA/ /12 16700 1000VA 00VA/ 00VA.
2. Ensure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit’s rated
capacity (700VA/390W for VP700ELCD, 00VA/10 550W for VP1000ELCD, 1200VA/720W for VP1200ELCD,
1600VA/960W for VP1600ELCD). If rated unit capacities are exceeded, an overload condition may occur and
cause the UPS unit to shut down or the circuit breaker trip.
3. There are many factors that can aect the amount of power that your computer system will require. For optimal
system performance keep the load below 80% of the unit’s rated capacity.
BASIC OPERATION
DESCRIPTION
1. Power Switch
Used as the master on/o switch for equipment connected to the battery power supplied outlets.
2. Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges
and spikes.
3. LCD Module Display
High resolution and intelligent LCD display shows all the UPS information with icons and messages. For more
information, please refer to the Function Setup Guide
4. Display / Select Button
The button can be used to select the LCD display contents including Input Voltage, Output Voltage, and
Estimated Run Time. For more information, please refer to the Function Setup Guide.
5. Mute / Enter Button
The button can be used to silence the alarm, conrm the settings, and enter into the functions. For more
information, please refer to the Function Setup Guide.
6. Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, network or Ethernet
connection (RJ11/RJ45).
7. Serial/ USB Port to PC
The Serial and USB port allow connection and communication from DB-9 serial or USB port on the computer to
the UPS unit. The UPS communicates its status to the PowerPanel
® Personal software.
NOTE: Only one of these two ports can be used as communication and control of the UPS unit at the same
time.
8. Circuit Breaker
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection
9. AC Input
Connect AC Power cord to a properly wired and grounded outlet.
10. Battery Backup and Surge Protected Outlets
The unit has several battery powered/surge suppression outlets for connected equipment to ensure temporary
uninterrupted operation of your equipment during a power failure. Check the type and quantity of outlets for
dierent models in the following table.
11. Surge Protected Outlets
Provides surge protection for devices that don’t require battery backup.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is
recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss may occur during
shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will
charge in both the on and o position.
Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. The
rst time you turn the UPS , you will need to have it connected to AC power or it will not power up. on
2. With the UPS unit o and unplugged, connect the computer, monitor, and any externally powered data storage
device (Zip drive, Jazz drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug a laser
printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery
power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
3. To protect the network, connect a network cable from the wall jack outlet to the IN jack of the UPS. Then connect
network cable from the OUT jack on the UPS to the computer or network device.
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected
by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner,
refrigerator, copier, etc. Avoid using extension cords.
5. Depress the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep".
6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn
the UPS o and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds.
Make sure the circuit breaker is depressed and then turn the UPS on.
7. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will
automatically recharge.
8. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
9. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery
every three months to ensure battery life.
TECHNICAL SPECIFICATIONS
Model
VP700E LCD
VP1000E LCD
VP1600E LCD
Capacity
700VA/390W
1000VA/ 550W
1600VA/96 0W
Input
Nominal Input Voltage
220-240V
Voltage Range
167-295Vac
Frequency Range
50/60Hz +/- 5 (Auto Sensing) Hz
AVR Function
Yes
Output
On Battery Output Voltage
230V -10% +/
On Battery Output Frequency
50/60Hz -1% +/
Overload Protection
On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Maximum Dimensions (WxH ) xD
100 60 x 227 x 2 mm
100 81 55 x 2 x 3 mm
Weight (kg)
5.1 kg
6.2 kg
10.4 kg
Battery
Sealed Maintenance Free Lead
Acid Battery
12V/7Ah x 1
12V/9Ah x 1
12V/9Ah x 2
Typical Recharge Time
6-8 hours to 90%
Warning Diagnostics
Indicators
Power On, LCD Display
Audible Alarms
On Battery, Low Battery, Overload
Environmental
Operating Temperature
0 C to 40C
Operating Relative Humidity
0 to 90%
Communication
PowerPanel®Personal Software
Windows 10 / 8 / 7 / Vista / XP / 2000, Server2012 / 2008 / 2003, Linux
Management
Auto-Charger
Yes
Auto-Restart
Yes
USB interface
Yes
FUNCTION SETUP GUIDE
BUTTON DESCRIPTION
Power On:
Press and hold the POWER button. You will hear a constant tone for 1 second,
followed by a short beep. Release the button after the short beep.
Power O:
Press and hold the POWER button. You will hear a constant tone for 1 second,
followed by two short beeps. Release the button after the two short beeps.
DISPLAY:
Press the button for 3 seconds to change current LCD status between "LCD in Sleep
1 minute (beep twice and "LCD Sleep in s )" 30 minutes (beeps once)".
LCD Sleep in 1 minute: In Line mode, LCD screen will o automatically be
after 1 min of inactivity.
LCD Sleep in 30 minute: In Line mode, LCD screen will o automatically be
after 30 min of inactivity.
In Battery mode, LCD screen will be always on.
SELECT:
Short press the button to view the information about the UPS or scroll down function /
option menu in Setup Mode.
MUTE:
Press the button for 3 seconds to enable the audible alarm (beeps once) or disable
(beeps twice) the audible alarm.
ENTER:
Short press the button to conrm the settings or enter into the functions.
Enter into Setup Mode:
Press both of the “SELECT” and “ENTER” at the same time for approximately 3
seconds to access the setup mode’s 11 functions.
Select Function:
Short press the “SELECT” button to scroll down the function/ option menu.
Short press the "ENTER" button to enter into set up options.
Conrm Option:
When an option is selected, short press the “ENTER” button.
After the setting has been conrmed, the LCD screen will stop ashing.
VP700/1000ELCD
VP1200/1600ELCD
Copyright © 20 - -20 Cyber Power Systems, Inc. All rights reserved. K01 0000879 00
Function
LCD Display
Options
Default
Description
Utility Power
CUSt Only when MIN :
or MAX I Voltage is /P
congured.
Poor (167 295V~ V)
Normal (171V~291V)
Good (175V~287V)
ESC
(Escape to Function
Menu)
Poor
This function determines how the
UPS will switch to Battery Mode.
3 dierent output voltage ranges can
be chosen according to the quality of
the AC utility service in your location.
If your utility service is not stable,
you can select Poor (167V~295V).
The UPS will go to Battery Mode
less often to tolerate the utility power
uctuations.
If your utility service is stable, you
can select Good (175V~287V) The .
unit will go Battery Mode more to
often.
MAX I/P
Voltage
H2 , H2 , H2 95 91 87
ESC
(Escape to Function
Menu)
H295V
In Utility Power settings, only 3 types
of xed voltage ranges can be
chosen.
However, you can ne tune the MAX
I/P voltage in this function.
If the utility voltage is usually high,
and the connected equipment can
work in this condition, you can set
the input voltage range higher to
reduce the UPS from going to
Battery Mode as often.
MIN I/P
Voltage
L1 , L171, L175 67
ESC
(Escape to Function
Menu)
L167V
In Utility Power settings, only 3 types
of voltage ranges can be chosen.
However, you canne tune the MIN
I/P voltage in this function.
If the utility voltage is usually low,
and the connected equipment can
work in this condition, you can set
the input voltage range lower to
reduce the UPS from going to AVR
Mode or Battery Mode as often.
Sensitivity
Low
Medium
High
ESC
(Escape to Function
Menu)
Medium
If the connected equipment can
tolerate more power events
(Example: unstable power often
associated with stormy weather),
select Low Sensitivity. The UPS will
go to Battery Mode less often.
If the connected equipment is more
sensitive to power events, select
High Sensitivity. The UPS will go to
Battery Mode more often.
Low Battery
Warni ng
5~8 mins
ESC
(Escape to Function
Menu)
5 mins
The audible alarm will sound when
the remaining runtime is less than
the value selected.
Self Test
(Battery Test)
YES
ESC
(Escape to Function
Menu)
No
Action
In Line Mode, select YES to perform
a Self Test on the battery.
Audible Alarm
b.on
b.oFF
ESC
(Escape to Function
Menu)
b.on
"b.on is buzzer enable; "
" b.oFF” is buzzer disable.
If b.oFF is selected, the unit will
mute all alarms except for fault or
overload condition.
You can also set the audible alarm
with the MUTE button mentioned
before.
LCD Sleep
1, 5, 10, 30 min(s)
ESC
(Escape to Function
Menu)
S.1 min
In Line Mode, LCD screen can be
congured to sleep automatically
after 1, 5, 10, or 30 min(s) of
inactivity.
I Battery Mode, LCD screen is n
always on.
Last Fault
Reason
There is no setting in this page. This
page will only show the error code
for last fault reason.
E01 : Charger fault (Over Charge)
E02 : Charger fault (No Charge)
E21 : Output short.
E22 : Over load.
Back to
Default
Settings
YES
ESC
(Escape to Function
Menu)
No
Action
Select YES to restore the UPS
factory default settings.
Return to
Status
Display
--
Press the ENTER Button to leave
setup mode and go back to the
Status Display.
TROUBLESHOOTING
Problem
Possible Cause
Solution
Circuit breaker button is
projecting from the back of the
unit.
Circuit breaker has tripped due to
an overload.
Turn the UPS o and unplug at least one piece of
equipment. Wait 10 seconds, reset the circuit
breaker by depressing the button, and then turn
the UPS on.
The UPS does not perform
expected runtime.
Battery not fully charged.
Recharge the battery by leaving the UPS plugged
in.
Battery is slightly worn out.
Contact CyberPower about replacement batteries.
The UPS will not turn on.
The on/o switch is designed to
prevent damage by rapidly
turning it o and on.
Turn the UPS o. Wait 10 seconds and then turn
the UPS on.
The battery is worn out.
Contact CyberPower about replacement batteries.
Mechanical problem.
Contact CyberPower.
PowerPanel® Personal is
inactive.
The USB cable is not connected.
Connect the USB / serial cable to the UPS unit
and an open USB / serial port on the back of the
computer.
The unit is not providing battery
power.
Shutdown your computer and turn the
UPS o. Wait 10 seconds and turn the
UPS back on. This should reset the unit.
Cyber Power Systems, Inc.
For more information, visit www.cyberpower.com
Manufacturer: Cyber Power Systems Inc.
11F., No.26, Jinzhuang Rd., Neihu Dist., Taipei City 114, Taiwan


Product specificaties

Merk: CyberPower
Categorie: UPS
Model: VP700ELCD
Kleur van het product: Zwart
Gewicht: 5140 g
Breedte: 100 mm
Diepte: 260 mm
Hoogte: 227 mm
Snoerlengte: 1.5 m
Geluidsniveau: 40 dB
Gewicht verpakking: 5760 g
Breedte verpakking: 300 mm
Diepte verpakking: 143 mm
Hoogte verpakking: 335 mm
Gebruikershandleiding: Ja
Materiaal behuizing: Kunststof
LED-indicatoren: Ja
Vormfactor: Tower
USB-poort: Ja
Meegeleverde kabels: USB-kabel
Land van herkomst: China
Aantal USB 2.0-poorten: 1
Soort serieële aansluiting: RS-232
Aantal Ethernet LAN (RJ-45)-poorten: 2
Certificering: CE, RCM
RS-232 port: 1
Geluidsalarm(en): Ja
Responstijd: 4 ms
Duurzaamheidscertificaten: RoHS
Bekabelingstechnologie: 10/100/1000Base-T(X)
Uitgangsvermogen: 390 W
Accu/Batterij oplaadtijd: 8 uur
Temperatuur bij opslag: -20 - 50 °C
Stroomspanning bescherming: Overspanning
Frequentie: 50/60 Hz
Luchtvochtigheid bij opslag: 0 - 90 procent
Naleving van duurzaamheid: Ja
Hoogte, in bedrijf: 0 - 3000 m
Hoogte bij opslag: 0 - 3000 m
Seriële poort(en): 1
Stekker: C14 stekker
Warmtedissipatie: 9.5 BTU/h
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 90 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Type beeldscherm: LCD
Code geharmoniseerd systeem (HS): 8504408590
Surge energy rating: 450 J
Aantal AC uitgangen: 4 AC-uitgang(en)
Stopcontacttypes: Type F
Stroom (max.): 3.04 A
Output power capacity: 0.7 kVA
Ingang operation voltage (min): 167 V
Ingang operation voltage (max): 295 V
Uitgang operation voltage (max): 230 V
UPS-topologie: Line-interactive
Aantal input fases: 1
Typische backup tijd op halve lading: 10 min
Typische backup tijd op volledige lading: 1 min
Seriële interface: Ja
Output frequentie: 50/60 Hz
Hoorbare alarmstanden: Alarm when on battery, Fault, Low battery alarm, Overload alarm
Uitgangsspanningsregeling: 10 procent
Aantal output fases: 1
EMI/RFI geluidsfiltering: Ja
Spanningsbeveiliging: Ja
Golfvorm: Sinus
Automatic Voltage Regulation (AVR): Ja
USB-poorttype: USB Type-B

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower VP700ELCD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS CyberPower

Handleiding UPS

Nieuwste handleidingen voor UPS

Apc

Apc RBC9 Handleiding

24 September 2024
Apc

Apc RBC22 Handleiding

24 September 2024
Apc

Apc AP9626 Handleiding

24 September 2024
Apc

Apc 66077 Handleiding

17 September 2024
Apc

Apc 66057 Handleiding

17 September 2024
Equip

Equip ZEUS51E Handleiding

5 September 2024