User’s Manual
Professional Rack Mount LCD XL Series
PR1000ELCDRTXL2U/PR1500ELCDRTXL2U/
PR2200ELCDRTXL2U
K01-0000125- 01
EN
2
Copyright © 2016 CyberPower Systems, Inc.
This manual contains important instructions. Please read and follow all instructions carefully during installation
and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate the
UPS.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection.
DO NOT plug the UPS into an outlet that is not grounded. If you need to power-drain this equipment, turn off
and unplug the unit .
CAUTION! The battery can power hazardous components inside the unit, even when the AC input power is
disconnected.
CAUTION! The UPS should be near the connected equipment and easily accessible.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor
area, free of conductive contaminants. (Please see specifications for acceptable temperature and humidity
range).
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the battery. an
There are no user serviceable parts inside, except for the battery.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing
the battery or installing a computer com ponent.
CAUTION! To reduce the risk of fire, connect the UPS to a circuit with 16 amperes maximum over-current
protection in accordance CE requirement. to
CAUTION! The AC outlet where the UPS is connected should be close to the unit and easily accessible.
CAUTION! Please use only VDE-tested, CE-marked mains cable, (e.g. the mains cable of your equipment), to
connect the UPS to the AC outlet.
CAUTION! Please use only VDE-tested, CE-marked power cables to connect any equipment to the UPS.
CAUTION! When installing the equipment, ensure that the sum of the leakage current of the UPS and the
connected equipment does not exceed 3.5mA.
CAUTION! This is permanently connected equipment and only qualified maintenance personnel may carry out
installations.
CAUTION! Do not unplug the unit from AC Power during operation, as this will invalidate the protective ground
insulation.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! Under no circumstances this
unit should be used for medical applications involving life support equipment and/or patient care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near
aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause
the machine to short out.
CAUTION! DO NOT USE WITH LASER PRINTERS! The power demands of laser printers are too large for a
UPS.
DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A
STRONG HEAT SOURCE!
DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING!
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO UPS OUTPUT SOCKETS.
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
3
Copyright © 2016 CyberPower Systems, Inc.
UNPACKING
The box should contain the following:
(1) UPS unit x 1; (2) User manual x 1; (3) Phone line x 1; (4) PowerPanel® Business Edition software download
card 1; (5) USB A+B type cable 1; (6) Rack mount Brackets x (7) Skids x 2; (8) Emergency Power Off x x 2;
Cable (gray) 1; (9) Serial Interface Cable (DB- 2; (10) Power cord x 4 (Power cord x 6 for x 9) x
PR2200ELCDRTXL2U)
AUTOMATIC VOLTAGE REGULATOR(AVR)
The can PR1000ELCDRT 2U/ 1500ELCDRT 2U/ 2200ELCDRT 2U XL PR XL PR XL
stabilize inconsistent utility power. Incoming utility power flucuations may be
damaging to important data and hardware but Automatic Voltage Regulation (AVR)
helps protect the computer against experiencing dangerous voltage levels. AVR
automatically adjusts low or high voltages keep equipment working at safe AC to
power levels (220/230/240V) without switching to battery. Your equipment can
operate normally even during power problems such as brownouts and blackouts.
The unit’s powerful sealed lead-acid batteries will provide power only if the
incoming voltage drops below 150V or increases above 0V.30
SYSTEM BLOCK DIAGRAM
HARDWARE INSTALLATION GUIDE
1. Battery charge loss may occur during shipping and storage. The first time the UPS is used, is strongly it
recommended to charge the batteries r at least hours to ensure that the batteries are at theirmaximum fo 12
charge capacity. To recharge the batteries, simply plug UPSinto an AC outlet, the batteries will charge
whether the UPS is powered on or not.
2. With the UPS off and unplugged, connect your computer, monitor, and any externally powered data
storage device (Hard drive, Tape drive, etc.) into the outlets. DO NOT plug a laser printer, copier, space
heater, vacuum, paper shredder or other large electrical device into the UPS. The power demands
of these devices will overload and possibly damage the unit.
3. To protect a fax, telephone, modem line or network cable, connect the telephone or network cable from the
wall jack outlet to the jack marked “IN” on the UPS. Then, connect a telephone cable or network cable from
the jack marked “OUT” on the UPS to the modem, computer, telephone, fax machine, or network device.
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g.
air conditioner, copier, etc). The warranty prohibits the use of extension cords, outlet strips, and surge
strips.
INSTALLING YOUR UPS SYSTEM (continued)
INSTALLING YOUR UPS SYSTEM
INSTALLING YOUR UPS SYSTEM (continued)
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | Smart App Sinewave PR2200ELCDRTXL2U |
Kleur van het product: | Zwart |
Gewicht: | 34900 g |
Geluidsalarm(en): | Ja |
Meegeleverde software: | PowerPanel Business Edition |
Uitgangsvermogen: | 1650 W |
Accu/Batterij oplaadtijd: | 6 uur |
Frequentie: | 50/60 Hz |
Afmetingen (B x D x H): | 433 x 480 x 88 mm |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Type batterij: | 12V, 9AH |
Output power capacity: | 2.2 kVA |
Netspanning, in bedrijf: | 230 V |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower Smart App Sinewave PR2200ELCDRTXL2U stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
15 November 2024
7 November 2024
7 November 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024
22 Oktober 2024