CyberPower RT650EI Handleiding
CyberPower
UPS
RT650EI
Lees hieronder de đź“– handleiding in het Nederlandse voor CyberPower RT650EI (2 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 10 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
EN
RT650EI / RT500EI
User’s Manual
K01-0000540
-00
Thank you for purchasing a CyberPower product. Please take a few minutes to
register your product at
www.c
yberpower.com/registration. Registration certifies your product's warranty, confirms your
ownership
in the event of a product loss or theft
and entitles you to free technical support.
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions that should be followed during installation and maintenance of
the UPS and batteries.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and
humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery.
There are no user serviceable parts inside, except for thebattery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is
disconnected.
CAUTION! The UPS must be connected to an grounded AC power outlet with fuse or circuit breaker
protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off
and unplug the unit.
CAUTION! To avoid electrical shock, turn off the unit and unplug it form the AC power source before
servicing the battery or installing a computer component.
CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
CAUTION! Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may
be toxic.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell
products for life support or medical applications. DO NOT use in any circumstance that would affect
operation and safety of life support equipment, any medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with
or near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not
use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during
transit and the damp environment can cause the unit to short out.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS unit (b) User’s manual (c) USB device cable (d) IEC to IEC power cord
*PowerPanel® Personal Edition software is available on our website. Please visit
www.cyberpower.com and go to the Software Section for free download.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity
(650VA/400W for RT650EI and 500VA/300W for RT500EI). If the rated capacities of the unit are
exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to
trip.
2. There are many factors that can affect the amount of power that your electronic equipment will require.
For optimal system performance keep the load below 80% of the unit’s rated capacity.
DESCRIPTION
1. LED Indicators
The LED indicators will illuminate to show the status of power: on line, on battery, overload, replace
battery.
2. Power Switch
To turn the UPS ON, press the power button for approximately 2 seconds - you will hear a constant tone
and release after a short beep.
To turn the UPS OFF, press the power button for approximately 2 seconds - you will hear a constant
tone and release after two short beeps.
Mute mode: The audible alarm can be turned Off or On by quickly pressing the POWER button twice.
The default setting is for the Alarm On. To turn the Alarm Off, quickly press the power button twice. You
will hear two short beeps when the Alarm is turned Off. To turn the Alarm back On, quickly press the
power button twice. You will hear a single short beep when the Alarm is turned On. *When the Alarm is
turned Off, there will be no audible notification when the UPS goes to Battery mode or reaches a low
battery state.
3. Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, network or
Ethernet connection (RJ11/RJ45).
4. USB Port to PC
The USB port allows connection and communication between the USB port on the computer and the
UPS unit. The UPS communicates its status to the PowerPanel® Personal Edition software.
5. Communication Port to PC
This port allows connection and communication between the UPS and computer. The UPS
communicates its status to the PowerPanel® Personal Edition software. For information regarding
ordering a serial cable for the unit, please contact technical support at CyberPower System.
NOTE: Only one of communication port and USB port can be used as communication and control of the
UPS unit at one time.
6. Battery and Surge Protected Outlets
The unit has battery powered/surge suppression outlets to ensure temporary uninterrupted operation of
your equipment during a power failure. (DO NOT plug a laser printer, paper shredder, copier, space
heater, vacuum cleaner, sump pump, or other large electrical device into the “Battery and Surge
Protected Outlets.” The power demands of these devices will overload and possibly damage the
unit.)
7. Circuit Breaker
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.
8. AC Input
Connect the AC Power cord to a properly wired and grounded outlet.
1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure
the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8
hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet,
the battery will automatically charge when it’s turned on or turned off.
Note: This UPS is designed with a safety feature to keep the system from being turned on during
shipment. The first time you turn the UPS on, you will need to have it connected to AC power or it
will not power up.
2. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals
requiring battery backup from the SURGE & BATTERY outlets. DO NOT plug a laser printer, paper
shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical device into
the “Battery and Surge Protected Outlets”. The power demands of these devices will overload
and possibly damage the unit.
3. To protect a fax, phone, or modem line, connect a telephone cable from the wall jack outlet to the IN jack
of the UPS. Connect a telephone cable from the UPS OUT jack to protect a modem port on the computer,
a telephone, or fax machine.
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g.
air conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips,
and surge strips in conjunction with the UPS unit.
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this,
turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets.
Make sure the circuit breaker is depressed and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in
storage, recharge the battery every three months to ensure optimal battery life.
8. Ensure the wall outlet and UPS are located near the equipment being attached for
proper accessibility.
9. The UPS can lie down on the left direction during operation. DO NOT lie down on
the other side which may block the ventilation hole and hinder the heat dissipation.
CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.
Service the battery under the supervision of personnel knowledgeable of batteries and their
precautions.
CAUTION! Use only the specified type of battery. See your dealer for replacement batteries.
CAUTION! The battery may present the risk of electrical shock. Do not dispose of batteries in a fire, as they
may explode. Follow all local ordinances regarding proper disposal of batteries.
CAUTION! Do not open or mutilate the batteries. Released electrolyte is harmful to the skin and eyes and
may be toxic.
CAUTION! A battery can present a high risk of short circuit current and electrical shock. Take the following
precautions before replacing the battery:
1. Remove all watches, rings or other metal objects.
2. Only use tools with insulated handles.
3. DO NOT lay tools or other metal parts on top of battery or any battery terminals.
4. Wear rubber gloves and boots.
5. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground.
CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK! The likelihood of
such shock will be reduced if such grounds are removed during installation and maintenance (applicable to a
UPS and a remote battery supply not having a grounded circuit)
îš„ TO REPLACE THE BATTERY
1. Turn off and unplug all connected equipment.
2. Unplug it from the AC power source.
3. Turn the UPS on its side.
4. Remove the retaining screw.
5. Slide the battery compartment cover completely off of the unit.
6. Remove the battery from the compartment.
7. Disconnect the battery wires from the battery.
8. Install the replacement battery by connecting the red wire and black wire to the positive (+) and
negative (-) terminal of the battery.
9. Put the battery back into the compartment.
10. Slide back the battery compartment cover and tighten the retaining screw.
11. Charge the unit for 8 hours to fully charge the battery.
BASIC OPERATION
INSTALLING YOUR UPS SYSTEM
IMPORTANT SAFETY INSTRUCTIONS
PRODUCT REGISTRATION
HARDWARE INSTALLATION GUIDE
REPLACING THE BATTERY
DEFINITIONS FOR ILLUMINATED LED INDICATORS
On
Line
On
Battery
Overload
Replace
Battery
Alarm
CONDITION
On
Off
Off Off
Off
Normal
Off
On
Off Off
Beep twice
every 30
seconds
Utility Failure- The UPS is providing
power to battery protected outlets
from its battery.
Off
Flash
Off Off
Rapid
Beeping
every 1/2
second
Utility Failure - The UPS is
providing battery power. Rapid
beeping indicates the unit will run out
of power shortly.
Off
Off
One Flash
every 5
seconds
Off
Constant
tone
Overload Fault - Occurs when
connected equipment exceeds the
listed capacity of the UPS. Turn the
UPS off, unplug at least one piece of
equipment from battery outlets, wait
10 seconds, reset the circuit breaker
and turn the unit on.
Off
Off
On/Flash
Off
C
onstant
tone
Short Fault (two flashes every 5
seconds
) -
Unplug at least one piece
of equipment from battery outlets
and turn the UPS on again.
UPS Fault
(constantly illuminate)
-
Contact CyberPower Systems for
support.
On/Off
Off/On
Flash
Off
Beep every
one second
Charger Fault (three flashes every 5
seconds
) - Contact CyberPower
Systems for support.
On
Off
Off
Flash
Beep every
two
seconds in
30 seconds
Battery is worn out or
disconnected
– Make sure the
battery is connected or replace a
new battery.
CyberPower’s Green Commitment
CyberPower is dedicated to the development of green products, and has adopted
Green practices throughout its business, including: membership in Climate Savers
Computing Initiative (CSCI), accordance with the Restriction on Hazardous Substances
(RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols, as well as ISO
14001 and IECQ QC080000. CyberPower pledges to provide the advanced energy
solution for the environment and become a leading eco-friendly organization in the UPS
industry.
Reduce Energy Cost with GreenPower UPSTM Technology
CyberPower’s goal is not only to provide eco-friendly products but also to bring the best value for consumers.
The advanced energy-saving design improves the operating efficiency and eliminates waste energy
consumption. As a result, consumers will enjoy significant energy cost savings with the adoption of
GreenPower UPSTM
technology.
In line mode, the AC input voltage may not be stable all the time, to prevent the connected equipment
from damage caused by the unexpected voltage fluctuations, please adjust the sensitivity of the unit
by the steps as follows:
1. Please make sure that the UPS is in LINE MODE.
2. To Enter the Sensitivity Setup mode, press the Power Button for 10 seconds until all indicators flash 2
seconds rapidly.
3. The unit will show the current sensitivity setting, as shown in the following table.
4. To select Low Sensitivity setting: shortly press power button until one red indicator (the last one)
illuminate.
5. To select Medium Sensitivity setting, press the power button until both red indicators (the third and fourth
from the top) illuminate.
6. To select High Sensitivity setting, press the power button until yellow and both red indicators (bottom
three) illuminate.
7. To set up a level of sensitivity, hold down the power button until the green indicator (the first one)
illuminates.
8. Once in setup mode, if there is no action within 5 seconds, the unit will exit setup mode and no setting is
done.
Indicators
Illuminate
Sensitivity
Input Voltage
Range
Description
1
(Red) Low
176 – 272 Vac
If the connected equipment can tolerate more power
events (example: unstable power often associated
with stormy weather), select Low Sensitivity and the
UPS will go to Battery Mode less often.
2
(Red, Red)
Medium
(Default)
192 – 264 Vac
The UPS will go to Battery Mode if the input voltage
is beyond the range.
3
(Yellow, Red,
Red)
High
200 – 254 Vac
If the connected equipment is more sensitive to
power events, select High Sensitivity and the UPS
will go to Battery Mode more often.
Problem
Possible Cause
Solution
Circuit breaker button is
projecting from the back of
the unit.
Circuit breaker has been
tripped due to an overload.
Turn the UPS off and unplug at least one
piece of equipment. Wait 10 seconds, reset
the circuit breaker by pressing the button,
and then turn the UPS on.
The UPS does not perform
expected runtime.
Battery not fully charged.
Recharge the battery by leaving the UPS
plugged in.
Battery is worn out.
Please contact CyberPower Systems about
replacement batteries.
The UPS will not turn on.
The on/off switch is
designed to prevent
damage from rapidly
turning it off and on.
Turn the UPS off.
Wait 10 seconds and then
turn the UPS on.
The unit is not connected
to an AC outlet.
The unit must be connected to a 230V
50/60Hz outlet.
The battery is worn out.
Please contact CyberPower Systems about
replacement batteries.
Mechanical problem.
Please c
ontact CyberPower Systems.
The frequency is outside of
the operating range of
50/60±3Hz.
Turn the UPS off. Make sure the frequency
range is within
50/60±3
Hz. Or you can turn
the UPS on in battery mode.
PowerPanel
® Personal
Edition is
inactive (all icons
are gray).
The USB cable is not
connected.
Connect the USB / serial cable to the UPS
unit and an open USB / serial port on the
back of the computer. You must use the
cable that came with the unit.
NOTE:
Only one of communication port
and
USB port
can be used as communication and
control of the UPS unit at one time.
The USB cable is
connected to a bad USB
port.
Check for a different USB port and plug the
cable in
.
The unit is not providing
battery power.
Shutdown your computer and turn the UPS
off.
Wait 10 se
conds and turn the UPS back
on. This should reset the unit.
Additional troubleshooting information can be found at “Support” at www.cyberpower.com
Model
RT500EI
RT650EI
Capacity
500 VA / 300W
650 VA / 400W
Input
Nominal Input Voltage
230Vac
Input Frequency
50/60Hz ± 3Hz
Ouput
On-Battery Output Voltage
230Vac ± 10%
On-Battery Output Frequency
50/60Hz ± 1% (Auto-sensing)
On-Battery Output Wave Form
Simulated Sine wave
Status Indicators
Indicators
On Line, On Battery, Overload, Replace Battery
Audible Alarms
On Battery, Low Battery, Overload
Environment
Operating Temperature
32°F to 113° F / 0° C to 45° C
Operating Relative Humidity
0 to 95% non-condensing
Physical
Size (W x H x D)
3.6” x 6.5” x 11.0”
Net Weight
4.08 kg
4.58 kg
Battery
Battery
Sealed Maintenance Free Lead Acid Battery
User Replaceable
Yes
Typical Battery Recharge Time
8 hours typical from total discharge
Typical Battery Life
3 to 6 years, depending on number of discharge/recharge cycles
Communication
PowerPanel® Personal Edition
Software
Windows 10 / 8 / 7 / Vista / XP / 2000, Server2012 / 2008 / 2003,
Linux
Certification
Certification
CE
For more information, visit www.cyberpower.com
Manufacturer: Cyber Power Systems Inc.
6F, No.32, Sec.1, Chenggong Rd.Nangang District, Taipei 115, Taiwan
All rights reserved. Reproduction without permission is prohibited.
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING
FUNCTION SETUP GUIDE – SENSITIVITY SETUP
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | RT650EI |
Kleur van het product: | Zwart |
Gewicht: | 4650 g |
Breedte: | 91.4 mm |
Diepte: | 279.4 mm |
Hoogte: | 165.1 mm |
Snoerlengte: | 1.83 m |
Gewicht verpakking: | 5200 g |
Breedte verpakking: | 382 mm |
Diepte verpakking: | 154 mm |
Hoogte verpakking: | 217 mm |
Materiaal behuizing: | Kunststof |
LED-indicatoren: | Status, Battery replacement |
Vormfactor: | Tower |
USB-poort: | Ja |
Meegeleverde kabels: | Input power cable, USB cable |
Aantal USB 2.0-poorten: | 1 |
Soort serieële aansluiting: | RS-232 |
Aantal Ethernet LAN (RJ-45)-poorten: | 1 |
Ondersteund aantal accu's/batterijen: | 1 |
Certificering: | CE |
RS-232 port: | 1 |
Geluidsalarm(en): | Ja |
Responstijd: | 10 ms |
Duurzaamheidscertificaten: | RoHS |
Meegeleverde software: | PowerPanel Personal Edition |
Uitgangsvermogen: | 400 W |
Accu/Batterij oplaadtijd: | 8 uur |
Temperatuur bij opslag: | -15 - 45 °C |
Stroomspanning bescherming: | Overbelasting |
Frequentie: | 50/60 Hz |
Luchtvochtigheid bij opslag: | 0 - 95 procent |
Hoogte, in bedrijf: | 0 - 3000 m |
Hoogte bij opslag: | 0 - 15000 m |
Modem (RJ-11) poort: | 1 |
Stekker: | C14 stekker |
Bedrijfstemperatuur (T-T): | 0 - 45 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Code geharmoniseerd systeem (HS): | 85078000 |
Surge energy rating: | 810 J |
Aantal AC uitgangen: | 4 AC-uitgang(en) |
Stopcontacttypes: | C13 stekker |
Stroom (max.): | 5 A |
Output power capacity: | 0.65 kVA |
Ingang operation voltage (min): | 192 V |
Ingang operation voltage (max): | 264 V |
Uitgang operation voltage (min): | 230 V |
Uitgang operation voltage (max): | 230 V |
UPS-topologie: | Stand-by (Offline) |
Aantal input fases: | 1 |
Typische backup tijd op halve lading: | 15 min |
Typische backup tijd op volledige lading: | 5 min |
Hot-swap batterij: | Ja |
Seriële interface: | Ja |
Hoorbare alarmstanden: | Fault, Low battery alarm, Overload alarm |
Output voltage THD: | 5 procent |
Aantal output fases: | 1 |
EMI/RFI geluidsfiltering: | Ja |
Spanningsbeveiliging: | Ja |
Golfvorm: | Sinus |
Uitgangsfrequentieregeling: | 50/60 Hz |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower RT650EI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
15 November 2024
7 November 2024
7 November 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024
22 Oktober 2024