USER’S MANUAL
PFC SINEWAVE SERIES
OR1000PFCRT2U/OR1500PFCRT2U/
OR2200PFCRT2U
K01-00004 -02 88
EN
1
Copyright © 2018 Cyber Power Systems, Inc.
This manual contains important instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or
operate the UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and
humidity range).
CAUTION! For pluggable equipment, the socket-outlet shall be installed near the equipment and shall
be easily accessible.
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery.
Ensure the input power is removed before servicing the batteries. There are no user serviceable parts
inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power
is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection.
Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off and
unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before
servicing the battery or installing a computer component.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum
branch circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70.
CAUTION! The UPS is suitable for use in a computer room as defined in the Standard for the Protection
of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.
CAUTION! The EPO function is provided in UPS. EPO remote switch which is Push-Back button is
installed computer room outside by a phone line and not connected any other equipment.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! Under no circumstances
this unit should be used for medical applications involving life support equipment and/or patient care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or
near aquariums. Condensation from the aqua um can come in contact with metal electrical contacts and ri
cause the machine to short out.
CAUTION! DO NOT USE WITH LASER PRINTERS! The power demands of laser printers are too large
for a UPS.
CAUTION! DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT
OR NEAR A STRONG HEAT SOURCE!
CAUTION! DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING!
CAUTION! DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR DRYERS TO UPS
OUTPUT SOCKETS.
IMPORTANT SAFETY INSTRUCTIONS
Copyright © 2018 Cyber Power Systems, Inc.
2
UNPACKING
The box should contain the following:
(a) UPS unit x1; (b) User manual x1; (c) USB A+B type cable x1; (d) Rackmount bracket x2 (e) Vertical ;
stand x2; (f) Warranty registration card x1
AUTOMATIC VOLTAGE REGULATOR(AVR)
The OR1000PFCRT2U/OR1500PFCRT2U/OR2200PFCRT2U can stabilize inconsistent utility power.
Incoming utility power fluctuations may be damaging to important data and hardware but Automatic
Voltage Regulation (AVR) helps protect the computer against experiencing dangerous voltage levels. AVR
automatically adjusts low or high voltages to keep equipment working at safe AC power levels (110/120V)
without switching to battery. Your equipment can operate normally even during the power problems such
as brownouts and blackouts. The unit’s powerful sealed lead-acid batteries will provide power only if the
incoming voltage drops below 90V or increases above 0V. 14
SYSTEM BLOCK DIAGRAM
HARDWARE INSTALLATION GUIDE
1. Battery charge loss may occur during shipping and storage. The first time the UPS is used, it is
strongly recommended to charge batteries for at least 18 hours ensure that the batteries are at the to
their maximum charge capacity. To recharge the batteries, simply plug the UPS into an AC outlet the ,
batteries will charge whether the UPS is powered on or not.
2. With the UPS off and unplugged, connect your computer, monitor, and any externally powered data
storage device (Hard drive, Tape drive, etc.) into the outlets. DO NOT plug a laser printer, copier,
space heater, vacuum, paper shredder or other large electrical device into the UPS. The power
demands of these devices will overload and possibly damage the unit.
3. To protect a fax, telephone, modem line or network cable, connect the telephone or network cable
from the wall jack outlet to the jack marked “IN” on the UPS. Then, connect a telephone cable or
network cable from the jack marked “OUT” on the UPS to the modem, computer, telephone, fax
machine, or network device.
4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet
is protected by a fuse or circuit breaker and does not service equipment with large electrical demands
(e.g. air conditioner, copier, etc). The warranty prohibits the use of extension cords, outlet strips, and
surge strips.
INSTALLING YOUR UPS SYSTEM (continued) INSTALLING YOUR UPS SYSTEM
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | OR1500PFCRT2U |
Kleur van het product: | Zwart |
Gewicht: | 25200 g |
Snoerlengte: | 3 m |
Aantal USB 2.0-poorten: | 1 |
Aantal Ethernet LAN (RJ-45)-poorten: | 1 |
Certificering: | UL1778, cUL 107.3, FCC DOC B, RoHS |
Geluidsalarm(en): | Ja |
Responstijd: | 4 ms |
Meegeleverde software: | PowerPanel Business Edition |
Uitgangsvermogen: | 900 W |
Accu/Batterij oplaadtijd: | 8 uur |
Frequentie: | 47/63 Hz |
Gewicht (imperiaal): | 55.5 lbs |
Bedrijfstemperatuur, bereik: | 32 - 95 °F |
Afmetingen (B x D x H): | 431.8 x 88.9 x 388.62 mm |
Seriële poort(en): | 2 |
Modem (RJ-11) poort: | 1 |
Bedrijfstemperatuur (T-T): | 0 - 35 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 90 procent |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Afmetingen (B x D x H) (Brits): | 17 x 3.5 x 15.3 " |
Type beeldscherm: | LCD |
Type batterij: | 12V/7AH |
Surge energy rating: | 1840 J |
Output power capacity: | 1.5 kVA |
UPS-topologie: | Line-interactive |
Typische backup tijd op halve lading: | 21 min |
Typische backup tijd op volledige lading: | 7 min |
Hot-swap batterij: | Ja |
Emergency Power Off (EPO): | Ja |
Vervangings-batterij cartridge: | BP7-12/SH1228WFR |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower OR1500PFCRT2U stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
15 November 2024
7 November 2024
7 November 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024
22 Oktober 2024