User’s Manual
MEDICAL GRADE UPS SERIES
M550L / M750L / M1100XL
1
PRODCT REGISTRA
TION
INTENDED USE OF UPS SYSTEM
SAFETY COMPLIANCE STATEMENT
Thank you for purchasing a CyberPower product. Please take a few minutes to register your product
at . Registration certifies your product's warranty, confirms your ownership in
www.cyberpower.com
the event of a product loss or theft and entitles you to free technical support. Register your product
now to receive the benefits of CyberPower ownership.
CyberPower Medical Grade UPS systems are intended to support and protect non-medical and
medical computer devices that require leakage current reduction, surge protection, voltage
regulation, line noise filtering and battery backup during power outages and generator testing, both
inside and outside patient care vicinities. CyberPower Medical Grade UPS Systems come with
medical-grade receptacles and plugs that reduce the leakage.
FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Important: Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Canadian Compliance Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit
pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioélectrique subi, même si
le brouillage est susceptible d'en compromettre le fonctionnement.
CAN ICES-3 (A)/NMB-3(A)
2
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area free of conductive contaminants. (Please see specifications for acceptable
temperature and humidity range).
CAUTION! For pluggable equipment, the socket-outlet shall be installed near the equipment and
shall be easily accessible.
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the
battery. There are no user serviceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input
power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection.
Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off
and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before
servicing the battery.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum
branch circuit overcurrent protection in accordance with the National Electric Code, ANSI/NFPA
70.
CAUTION! Not for use in a computer room as defined in the Standard for the Protection of
information Technology Equipment, ANSI/NFPA 75.
CAUTION! DO NOT USE FOR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products life
support applications. DO NOT use in any circumstance that would affect the operation and safety
of life support equipment or patient care.
CAUTION! The Serial and USB ports of the UPS units allow the connection and communication with
computers, and the connected computers shall comply with UL/ IEC standards.
CAUTION! Combined systems shall comply with the standard IEC 60601-1-1, safety requirements for
medical electrical systems. On the other hands, the equipment which doesn’t comply with UL
60601-1 shall be kept outside patient environment, as defined in the standard.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not
use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use
the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused
during transit and the damp environment can cause the unit to short out.
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | M750L |
Kleur van het product: | Wit |
Gewicht: | 23949 g |
Breedte: | 220 mm |
Diepte: | 431 mm |
Hoogte: | 170 mm |
Snoerlengte: | 1.8 m |
Gebruikershandleiding: | Ja |
Vormfactor: | Mini Tower |
USB-poort: | Ja |
Meegeleverde kabels: | Serial, USB cable |
Accu/Batterij voltage: | 12 V |
Aantal USB 2.0-poorten: | 1 |
Soort serieële aansluiting: | RS-232 |
Ondersteund aantal accu's/batterijen: | 3 |
RS-232 port: | 1 |
Geluidsalarm(en): | Ja |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 600 W |
Batterij capaciteit: | 7 Ah |
Temperatuur bij opslag: | -15 - 45 °C |
Stroomspanning bescherming: | Overbelasting |
Frequentie: | 60 Hz |
Veiligheid: | UL1778, CSA, FCC 15 A (EMI), UL60601-1 |
Hoogte, in bedrijf: | 0 - 3000 m |
Stekker: | NEMA 5-15P-HG |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Type beeldscherm: | LCD |
Surge energy rating: | 1445 J |
Aantal AC uitgangen: | 6 AC-uitgang(en) |
Stopcontacttypes: | NEMA 5-15R |
Output power capacity: | 0.75 kVA |
Ingang operation voltage (min): | 88 V |
Ingang operation voltage (max): | 150 V |
Uitgang operation voltage (min): | 120 V |
Uitgang operation voltage (max): | 120 V |
UPS-topologie: | Line-interactive |
Typische backup tijd op halve lading: | 30 min |
Typische backup tijd op volledige lading: | 12 min |
Hot-swap batterij: | Ja |
Seriële interface: | Ja |
Output frequentie: | 60 Hz |
Hoorbare alarmstanden: | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
EMI/RFI geluidsfiltering: | Ja |
Golfvorm: | Pseudo sine |
Automatic Voltage Regulation (AVR): | Ja |
Oplaadduur batterij: | 8 uur |
Output vermogensfactor: | 0.8 |
USB-poorttype: | USB Type-B |
Contactdoos circuitonderbreker: | Ja |
Overdrachtstijd (Lijnmodus naar batterijmodus): | 10 ms |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower M750L stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
15 November 2024
7 November 2024
7 November 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024
22 Oktober 2024