1. Power Switch: Used as the master on/o switch for equipment connected to the battery power
supplied outlets. To turn the UPS ON, press the power button for approximately 2 seconds - you will
hear a constant tone (1 second) - and release after a short beep.
Alarm setting (For CP825AVRLCD-G/CP685AVRLCD-G): The audible alarm can be turned O or On
by double click the POWER button. The default setting is for the Alarm On. To turn the Alarm O,
double click the button. You will hear two short beeps when the Alarm is turned o. To turn the Alarm
back On, double click the button. You will hear a single short beep when the Alarm is turned on. *When
the Alarm is turned O, there will be no audible notification when the UPS reaches a low battery state.
2. Power On Indicator: This LED is illuminated when the utility power is normal and the UPS outlets are
providing power, free of surges and spikes.
3. Mode Switch (For CP825AVRLCD-G/CP685AVRLCD-G): Press the Mode Switch for approximately 3
seconds to enter setup mode to view options: Utility High/low Voltage range, sensitivity setup, LCD
sleep ON/OFF, battery test, buzzer ON/OFF, and low battery alarm. When an option is selected, wait
for 8 seconds for the setting to be confirmed. After the setting has been confirmed the LCD screen will
leave setup mode and go back to status display. If there is no action for 8 seconds during setup, the
LCD will also leave setup mode and go back to the status display.
4. Fault Indicator: This LED is illuminated if there is a problem with the UPS.
5. Mute Button (For CP800AVR/CP685AVR-G): Press the button for 2 seconds to enable the audible
alarm (beeps once) or disable (beeps twice) the audible alarm.
6. LCD module display (For CP825AVRLCD-G/CP685AVRLCD-G): LCD display shows all the UPS
information using icons and messages. For more information please review the “Definitions for
Illuminated LCD Indicators” section.
7. Battery and Surge Protected Outlets: The unit has four battery powered and surge protected outlets
to ensure temporary uninterrupted operation of your equipment during a power failure. (DO NOT plug
a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large
electrical device into the “Battery and Surge Protected Outlets.” The power demands of
these devices will overload and possibly damage the unit.)
8. Full-Time Surge Protection Outlets: The unit has four surge suppression outlets.
To turn the UPS OFF, press the power button for approximately 2 seconds - you will hear a constant
tone (1 second) - and release after two short beeps.
9. USB Port: The USB port allows connection and communication between the USB port on the
computer and the UPS unit.
10. Communication Protection Ports (For CP825AVRLCD-G): Communication protection ports, bi-
directional, will protect a 10/100/1000 Ethernet connection(RJ45).
11. Serial Port: Serial Port allow for bi-directional communication among the UPS and the computer.
The UPS can control the computer’s shutdown in case of an emergency, and at the same time, the
computer can monitor the UPS and alter its various programmable parameters.
12. Circuit Breaker & reset: Located on the side of the UPS, the circuit breaker provides overload and
fault protection.
13. Ground Screw: The ground screw is used for any equipment that needs a chassis ground connection.
14. Outlets Designed for AC Adapters: The UPS unit has four widely-spaced outlets. AC power adapters
can be plugged into the UPS without overlapping or blocking adjacent outlets.
REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA.
1. When replacing batteries, replace with the same number of the following battery: CyberPower /
RB1290 for CP825AVRLCD-G,CP800AVR; CyberPower / RB1270B for CP685AVRLCD-G,CP685AVR-G.
2. CAUTION! Risk of Energy Hazard, 12V, maximum 9 Ampere-hour battery. Before replacing batteries,
remove conductive jewelry such as chains, wrist watches, and rings. High energy through conductive
materials could cause severe burns.
3. CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
4. CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes.
It may be toxic.
5. CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following
precautions should be observed when working on batteries:
a. Remove watches rings, or other metal objects.
b. Use tools with insulated handles.
CAUTION: risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to local regulations.
TO REPLACE THE BATTERY
1. Turn o and unplug all connected equipment.
2. Unplug it from the AC power source.
3. Turn the UPS upside down.
4. Remove the 1 retaining screw.
5. Slide the battery compartment cover completely o of the unit.
6. Remove the battery from the compartment.
7. Disconnect the battery cables from the battery.
8. Install the replacement battery by connecting the red wire and
black wire to the positive (+) and negative (-) terminal of the battery.
9. Put the battery back into the compartment.
10. Slide back the battery compartment cover and tighten the retaining screw.
11. Charge the unit for 8 hours to fully charge the battery.
REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most
retailers that sell lead-acid batteries collects used batteries for recycling, as required by local regulations.
CP825AVRLCD-G | CP685AVRLCD-G | CP800AVR | CP685AVR-G
User’s Manual
PRODUCT REGISTRATION
IMPORTANT SAFETY INSTRUCTIONS
INSTALLING YOUR UPS SYSTEM
BASIC OPERATION
BASIC OPERATION CONT.
DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS
Thank you for selecting this CyberPower UPS product. This UPS is designed to provide
unsurpassed power protection, operation and performance during the lifetime of the product.
Please take a few minutes to register your product by visiting: CyberPowerSystems.com/
registration. Registration certifies your product’s warranty, confirms your ownership in the event
of a product loss or theft and entitles you to free technical support.
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or
operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and
humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery.
Turn o and unplug the unit before servicing the batteries. There are no user serviceable parts inside
except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power
is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection.
Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn o and
unplug the unit.
CAUTION! To avoid electric shock, turn o the unit and unplug it from the AC power source before
installing a computer component.
CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic
Computer/Data Processing Equipment, ANSI/NFPA 75.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch
circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell
products for life support or medical applications. DO NOT use in any circumstance that would aect
operation and safety of life support equipment, any medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or
near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not
use the unit on any transportation such as airplanes or ships. The eect of shock or vibration caused
during transit and the damp environment can cause the unit to short out.
INTRODUCTION
Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide
unsurpassed power protection, operation and performance during the lifetime of the product.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following: (a) UPS unit (b) User’s manual
(c) USB A+B type cable, *PowerPanel® Personal Edition software is available on our website. Please
visit CyberPowerSystems.com and go to the Software Section for free download.
OVERVIEW
The CP825AVRLCD-G/CP685AVRLCD-G/CP800AVR/CP685AVR-G provides complete power protection
from utility power that is not always consistent. The CP825AVRLCD-G/CP685AVRLCD-G/CP800AVR/
CP685AVR-G features 1030 Joules of surge protection. The unit provides long lasting battery backup
during power outages with maintenance free batteries.The CP825AVRLCD-G/CP685AVRLCD-G/
CP800AVR/CP685AVR-G ensures consistent power to your computer system and includes software that
will automatically save your open files and shutdown your computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The CP825AVRLCD-G/CP685AVRLCD-G/CP800AVR/CP685AVR-G stabilizes inconsistent utility power
to nominal levels that are safe for equipment. Unstable utility power can be damaging to important data
and hardware. With Automatic Voltage Regulation (AVR), damaging voltage levels are corrected to safe
levels. AVR automatically increases low utility power to a consistent and safe 110/120 volts.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity
(825VA/450W for CP825AVRLCD-G, 800VA/450W for CP800AVR, 685VA/390W for
CP685AVRLCD-G, CP685AVR-G). If the rated capacities of the unit are exceeded, an overload
condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
2. There are many factors that can aect the amount of power that your electronic equipment will
require. For optimal system performance keep the load below 80% of the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt.
However, after receiving a new UPS, to ensure the battery’s
maximum charge capacity, it is recommended that you charge
the battery for at least 8 hours. Your UPS is equipped with
an auto-charge feature. When the UPS is plugged into an AC
outlet, the battery will automatically charge whether the UPS
is turned on or turned o. Note: This UPS is designed with a
safety feature to keep the system from being turned on during
shipment. The first time you turn the UPS on, you will need to
have it connected to AC power or it will not power up.
2. With the UPS unit turned o and unplugged, connect your
computer, monitor, and any other peripherals requiring battery backup into the battery power supplied
outlets. Plug the other peripheral equipment (eg. printer, scanner, speakers, etc.) into the full-time
surge protection outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum
cleaner, sump pump, or other large electrical device into the “Battery and Surge Protected Outlets”.
The power demands of these devices will overload and possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet
is protected by a fuse or circuit breaker and does not service equipment with large
electrical demands (e.g. air conditioner, refrigerator, copier, etc.). The warranty
prohibits the use of extension cords, outlet strips, and surge strips in conjunction
with the UPS unit.
4. Press the power switch to turn the unit on. The Power On indicator light will
illuminate green and the unit will “beep” once.
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct
this, turn the UPS o and unplug at least one piece of equipment from the battery power supplied
outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period of time, cover it and store with the battery fully charged.
While in storage, recharge the battery every three months to ensure optimal battery life.
8. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
INTRODUCTION
CP825AVRLCD-G | CP685AVRLCD-G CP800AVR | CP685AVR-G
POWER FAULT ALARM
CONDITION
On O O Normal
On O
Beep twice
every 30
seconds
Utility Failure: The UPS is providing power to battery pow-
er-supplied outlets from its battery.
On O
Rapid
beeping every
½ second
Utility Failure: The UPS is providing battery power. Rapid
beeping indicates the unit will run out of power soon.
On/O
Flash once
every 5
seconds
Constant tone
Battery Mode or AC/Utility Power Mode Overload Fault:
Occurs when connected equipment exceeds the rating of
battery outlets of the unit. Please unplug at least one piece
of equipment from battery outlets.
O
Flash twice
every 5
seconds
Constant tone
Battery Output Short Fault: Please unplug at least one
piece of equipment from battery outlets and turn on the
UPS again. If the fault still exists, please contact Cyber-
Power Systems for support.
On
Flash 3
times every
5 seconds
Constant tone Charger Fault: Contact CyberPower Systems for support.
13
9
11
12
10
1
2
7
14
3
8
4
14
6
1
2
7
14
5
8
4
14
DEFINITIONS FOR ILLUMINATED LCD INDICATORS (CP825/685AVRLCD-G)
INPUT voltage meter: This meter measures the AC voltage that the UPS system is receiving from the
utility wall outlet. The UPS is designed to continuously supply connected equipment with stable output
voltage. In the event of a complete power loss, severe brownout, or over-voltage, the UPS relies on its
internal battery to supply consistent 110/120 output voltage. The INPUT voltage meter can be used as a
diagnostic tool to identify poor-quality input power.
OUTPUT voltage meter: This meter measure, in real time, the AC voltage that the UPS system is providing
to the computer during normal AC/Utility Power mode, and battery backup mode.
ESTIMATED RUNTIME: This displays the run time estimate of the UPS
with the current battery capacity and load.
NORMAL icon: This icon appears when the UPS is working under
normal conditions.
BATTERY icon: During a severe brownout or blackout, this icon appears and
an alarm sounds (two short beeps followed by a pause) to indicate the UPS is
operating from its internal batteries. During a prolonged brownout orblackout,
the alarm will sound continuously to indicate the UPS’s batteries are nearly out
of power. You should save files and turn o your equipment immediately or
allow the software to shut the system down.
OVER LOAD icon: This icon appears and an alarm sounds to indicate the
battery-supplied outlets are overloaded. To clear the overload, unplug some of your equipment from the
battery-supplied outlets until the icon turns o and the alarm stops.
BATTERY CAPACITY meter: This meter displays the approximate charge level of the UPS’s internal
battery in 20% increments. During a blackout or severe brownout, the UPS switches to battery power
(the BATTERY icon appears) and the battery charge level decreases.
LOAD CAPACITY meter: This meter displays the approximate output load level of the UPS battery outlets
in 20% increments.
SENSITIVITY meter: This meter displays the sensitivity level of the UPS. It is to control the sensitivity of
the UPS to switch to Battery Mode by selecting UPS shutdown voltage range. When the sensitivity is
increased, the UPS will switch to Battery Mode with less input power variation.
FAULT: The following number appears if there is a problem with the UPS. Press the POWER button to turn
the UPS o.
RUN_TIMEOUTPUTINPUT
Min
V
%
LOAD BATT. CAP.
100
The LCD display indicates a
variety of UPS operational
conditions. All descriptions
apply when the UPS is
plugged into an AC outlet
and turned on or when the
UPS is on battery.
*In line mode, the AC input voltage may not stable all the time. To prevent the connected equipment
from damage caused by the unexpected voltage fluctuations, please adjust the sensitivity of the unit
by visiting: www.cyberpowersystems.com and download the LCD setup guide. (CP825AVRLCD-G/
CP685AVRLCD-G); For CP800AVR/CP685AVR-G, please refer the steps as follows*
1. Please make sure that the UPS is in .
2. To Enter the Sensitivity Setup mode, press the MUTE Button for 6 seconds until all indicators flash
rapidly.
3. The unit will show the current SENSITIVITY setting, as shown in the following table.
4. To select LOW Sensitivity setting, shortly press power button until one red indicator flashes.
5. To select Medium Sensitivity setting, press the power button until green indicators flashes.
6. To select High Sensitivity setting, press the power button until green and red indicators flash.
7. To set up a level of sensitivity , hold down the Mute button until the first one indicator illuminates.
8. In setup mode, if there is no action within 7 seconds, the unit will exit setup mode, and no setting is done.
Indicators
Illuminate Sensitivity Description
1 (Red) LOW
If the connected equipment can tolerate more power events
(example: unstable power often associated with stormy weather),
select Low Sensitivity and the UPS will go to Battery Mode less
often.
2 (Green) Medium (Default) The UPS will go to Battery Mode if the power is unstable.
3 (Green, Red) High
If the connected equipment is more sensitive to power events,
select High Sensitivity and the UPS will go to Battery Mode more
often.
Additional troubleshooting information can be found at: CyberPowerSystems.com/support
Runtimes based on testing fully-charged, new batteries at normal operating conditions. Runtime curve is
approximate and varies based on battery age, level of charge at test, environment, and other variables.
Read the following terms and conditions carefully before using the CyberPower CP825AVRLCD-G/
CP685AVRLCD-G/CP800AVR/CP685AVR-G (the “CPS Product”). By using the CPS Product you consent to be
bound by and become a party to the terms and conditions of this Limited Warranty and Connected Equipment
Guarantee (together referred to as this “Warranty”). If you do not agree to the terms and conditions of this
Warranty, you should return the CPS Product for a full refund prior to using it.
Who is providing this warranty?
Cyber Power Systems (USA), Inc. (“CyberPower”) provides this Limited Warranty.
What does this warranty cover?
This warranty covers defects in materials and workmanship in the CPS Product under normal use and
conditions. It also covers equipment that was connected to the CPS Product and damaged because of
the failure of the CPS Product.
What is the period of coverage?
This warranty covers the CPS Product for three years from date of purchase and connected equipment for as long as
you own the CPS Product.
Who is covered?
This warranty only covers the original purchaser. Coverage ends if you sell or otherwise transfer the CPS Product.
How do you get warranty service?
1. Before contacting CyberPower, identify Your CPS Product model number, the purchase date, and each item of
Connected Equipment (e.g. computer tower, monitor, ink jet printer, cable modem, etc).
2. Visit our web site at: CyberPowerSystems.com/support or Call us at (877) 297-6937.
3. If your product requires warranty service you must provide a copy of your dated purchase receipt or invoice.
How do you open a connected equipment claim?
1. Call us at (877) 297-6937 or write to us at Cyber Power Systems (USA), Inc., 4241 12th Ave. E.,
STE 400, Shakopee, MN 55379, or e-mail at: claims@cpsww.com for instructions, within 10 days
of the occurrence.
2. When you contact CyberPower, identify the CPS Product, the purchase date, and the item(s) of Connected
Equipment. Have information on all applicable insurance or other resources of recovery/payment that are
available to the Initial Customer and Request a Claim Number.
3. You must provide a dated purchase receipt (or other proof of the original purchase) for the CyberPower unit
and connected equipment. You also need to provide a description of the damage to your
connected equipment.
4. Pack and ship the CPS product to CyberPower and, if requested, the item(s) of Connected Equipment, a
repair cost estimate for the damage to the Connected Equipment, and all claim forms that CyberPower
provides to you. Show the Claim Number on the shipping label or include it with the CPS product. You must
prepay all shipping costs, you are responsible for packaging and shipment, and you must pay the cost of the
repair estimate.
How long do I have to make a claim?
All claims must be made within ten days of the occurrence.
What will we do to correct problems?
CyberPower will inspect and examine the CPS Product. If the CPS Product is defective in material or
workmanship, CyberPower will repair or replace it at CyberPower’s expense, or, if CyberPower is unable to or
decides not to repair or replace the CPS Product (if defective) within a reasonable time, CyberPower will refund
to you the full purchase price you paid for the CPS Product (purchase receipt showing price paid is required). If
it appears that our CPS Product failed to protect any equipment plugged into it, we will also send you forms for
making your claim for the connected equipment. We will repair or replace the equipment that was damaged
because of the failure of our CPS Product or pay you the fair market value (NOT REPLACEMENT COST) of the
equipment at of the time of the damage. We will use Orion Blue Book, or another a third-party valuation guide,
or eBay, craigslist, or other source to establish that amount. Our maximum liability is limited to $200,000 for the
CP825AVRLCD-G/CP800AVR and $125,000 for the CP685AVRLCD-G/CP685AVR-G.
Who pays for shipping?
We pay when we send items to you; you pay when you send items to us.
What isn’t covered by the warranty?
1. This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of
the CPS Product or any data that is lost as a result of the failure or the restoration of data or records, or the
reinstallation of software.
2. This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental
limits of the CPS Product or the equipment connected to it, nor for damage while in transit or in storage, nor
if there has been improper operation or maintenance, or use with items not designed or intended for use
with the CPS Product, such as laser printers, appliances, aquariums, medical or life support devices, etc.
What are the limitations?
The sole and exclusive remedies of the Initial Customer are those provided by this Warranty.
1. This Warranty does not apply unless the CPS Product and the equipment that was connected to it were
connected to properly wired and grounded outlets (including compliance with electrical and safety codes
of the most current electrical code), without the use of any adapters or other connectors.
2. The CPS Product must have been plugged directly into the power source and the equipment connected to
the CPS Product must be directly connected to the CPS Product and not “daisy-chained” together in serial
fashion with any extension cords, another Product or device similar to the CPS Product, surge suppressor, or
power tap. Any such installation voids the Limited Warranty.
3. The CPS Product and equipment connected to it must have been used properly in a suitable and proper
environment and in conformance with any license, instruction manual, or warnings provided with the CPS
Product and the equipment connected to it.
4. The CPS Product must have been used at all times within the limitations on the CPS Product’s VA capacity.
The CPS Product was designed to eliminate disrupting and damaging eects of momentary (less than 1ms)
voltage spikes or impulses from lightning or other power transients. If it can be shown that a voltage spike
lasting longer than 1ms has occurred, the occurrence will be deemed outside the rated capabilities of the
CPS Product and the Limited Warranty is void. CyberPower Does Not Cover or Undertake Any Liability
In any event for any of the following:
1. Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of
software.
2. Damage from causes other than AC Power Line Transients, spikes, or surges on properly installed, grounded
and code-compliant 120 volt power lines in the United States and Canada; transients, surges or spikes on
standard telephone land lines, PBX telephone equipment lines or Base 10T Ethernet lines, when properly
installed and connected. (This exclusion applies, for example, to fluctuations in data transmission or
reception, by CATV or RF transmission or fluctuations, or by transients in such transmission.)
3. Damage from any circumstance described as excluded above with respect to the CPS Product.
4. Damages from fire, flood, wind, rain, rising water, leakage or breakage of plumbing, abuse, misuse or
alteration of either the product or the Connected Equipment.
5. CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment
Guarantee. CyberPower excludes any liability for direct, indirect, special, incidental or consequential
damages, whether for damage to or loss of property [EXCEPT FOR (AND ONLY FOR) the specific limited
agreement of CyberPower to provide certain warranty benefits regarding “Connected Equipment” under
this Warranty], loss of profits, business interruption, or loss of information or data. NOTE: Some States or
Provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation may not apply to you.
6. The CPS Product is not for use in high-risk activities or with aquariums. The CPS Product is not designed or
intended for use in hazardous environments requiring fail-safe performance, or for use in any circumstance
in which the failure of the CPS Product could lead directly to death, personal injury, or severe physical or
property damage, or that would aect operation or safety of any medical or life support device (collectively,
“High Risk Activities”). CyberPower expressl disclaims any express or implied warranty of fitness for High
Risk Activities or with aquariums. CyberPower does not authorize use of any CPS Product in any High Risk
Activities or with Aquariums. ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT.
Where can I get more information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly
excluded. CyberPower is the warrantor under this Limited Warranty. For further information please feel free to
contact CyberPower at Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379;
call us at (877) 297-6937; or e-mail at: claims@cyberpowersystems.com.
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment o and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help
SYSTEM FUNCTION BLOCK DIAGRAM
TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
FCC COMPLIANCE STATEMENT
LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE
PROBLEM POSSIBLE CAUSE SOLUTION
Circuit breaker
button is
projecting from the
back of the unit.
Circuit breaker has tripped due
to an overload.
Turn the UPS o and unplug at least one piece
of equipment. Wait 10 seconds, reset the
circuit breaker by depressing the button, and
then turn the UPS on.
The UPS does not
perform expected
runtime.
Battery not fully charged. Recharge the battery by leaving
the UPS plugged in.
Battery is worn out. Please contact CyberPower Systems about
replacement batteries at tech@cpsww.com
The UPS will
not turn on.
The on/o switch is designed
to prevent damage from
rapidly turning it o and on.
Turn the UPS o. Wait 10 seconds and then
turn the UPS on.
The unit is not connected
to an AC outlet.
The unit must be connected to a
120 V 60 Hz outlet.
The battery is worn out. Please contact CyberPower Systems about
replacement batteries at tech@cpsww.com
Mechanical problem. Please contact CyberPower Systems
at tech@cpsww.com
PowerPanel®
Personal Edition
is inactive (all
icons are gray).
The USB cable is
not connected.
Connect the USB cable to the UPS unit and an
open USB port on the back of the computer.
You must use the cable that came with the unit.
The USB cable is connected
to the wrong port.
Check the back of the computer for an
additional USB port. Move the cable to this port.
The unit is not providing
battery power.
Shutdown your computer and turn the UPS o.
Wait 10 seconds and turn the UPS back on. This
should reset the unit.
The USB power
ports are not
providing power
to the connected
devices.
The USB power port has Over
Current Protection design.
When the total current of
connected devices is over
2.1A, the USB power ports will
stop providing power to the
connected devices.
Turn the UPS o and unplug at least one piece
of device connected to the USB power port and
then turn the UPS on.
SERIES CP825AVRLCD-G CP685AVRLCD-G CP800AVR CP685AVR-G
MODEL CP825AVRLCDa CP685AVRLCDa CP800AVRa CP685AVRa
Capacity 825 VA/450 W 685 VA/390 W 800 VA/450 W 685 VA/390 W
Nominal Input Voltage 120Vac
Input Frequency 60 Hz ± 3 Hz
On-Battery
Output Voltage 120Vac ± 5%
On-Battery
Output Frequency 60Hz +/- 1%
Max. Load for
UPS Outlets 825 VA/450 W 685 VA/390 W 800 VA/450 W 685 VA/390 W
Max. Load for Full-Time
Surge Protection outlets 12 Amps
On-Battery Output
Wave Form Simulated Sine Wave Form
Surge Protection 1030 Joules
Operating Temperature + 32°F to 104°F/0°C to 40°C
Operating Relative
Humidity 0 to 90% non-condensing
Size (W x H x D) 11.02” × 6.81” × 3.47”
Net Weight 12.74 lbs 11.62 lbs 12.74 lbs 11.62 lbs
Typical Battery
Recharge Time 8 hours typical from total discharge
Typical Battery Life 3 to 6 years, depending on number of discharge/recharge cycles
Recommended Battery Sealed Maintenance Free Lead Acid Battery
Safety Approvals UL1778(UPS), cUL107., FCC/DoC Class B
ADVANCED ENERGY-SAVING PATENTED BYPASS TECHNOLOGY
CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy
costs by up to 75% compared to conventional UPS models. Even when utility power
is normal, conventional UPS models constantly pass power through a transformer. By
contrast, under normal conditions the advanced circuitry of a GreenPower UPS™ bypasses
the transformer. As a result, the power eciency is significantly increased while decreasing
waste heat, using less energy, and reducing energy costs. When an abnormal power
condition occurs, the GreenPower UPS™ automatically runs power through its transformer
to regulate voltage and provide “safe” power. Since utility power is normal over 88% of the
time, the GreenPower UPS™ operates primarily in its ecient bypass mode.
CYBERPOWER GREENPOWER UPSTM TECHNOLOGY
NORMAL MODE
BATTERY MODE
INPUT OUTPUT
EMI FILTER SURGE
PROTECTOR AVR
CHARGER
AC/DC INVERTER
BATTERY
K01-0000710-01
CyberPower encourages environmentally sound methods for disposal and recycling of its UPS
products. Please dispose and/or recycle your UPS and batteries in accordance to your local regulations.
This device is manufactured using environmentally-safe procedures in compliance with the Restriction
of Hazardous Substances directive.
For more information contact CyberPower at:
Cyber Power Systems (USA), Inc.
4241 12th Ave E., STE 400, Shakopee, MN 55379
Phone: (877) 297-6937; e-mail at: claims@cpsww.com.
© 2018 Cyber Power Systems (USA), Inc.
PowerPanel® Personal Edition is a trademark
of Cyber Power Systems (USA) Inc.
All rights reserved. All other trademarks are
the property of their respective owners.
IWARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the
State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
CyberPowerSystems.com
LINE MODE
FUNCTION SETUP GUIDE – SENSITIVITY SETUP
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | CP685AVRLCD |
Gewicht: | 6350 g |
Vormfactor: | Compact |
Aantal USB 2.0-poorten: | 1 |
Aantal Ethernet LAN (RJ-45)-poorten: | 1 |
Certificering: | UL1778, cUL 107.1, FCC DOC Class B |
Geluidsalarm(en): | Ja |
Responstijd: | 4 ms |
Uitgangsvermogen: | 390 W |
Accu/Batterij oplaadtijd: | 8 uur |
Temperatuur bij opslag: | -15 - 45 °C |
Frequentie: | 60 Hz |
Gewicht (imperiaal): | 14 lbs |
Bedrijfstemperatuur, bereik: | 32 - 95 °F |
Afmetingen (B x D x H): | 279.4 x 89 x 165 mm |
Modem (RJ-11) poort: | 1 |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Afmetingen (B x D x H) (Brits): | 11 x 3.5 x 6.5 " |
Surge energy rating: | 890 J |
Input-connectietype: | NEMA 5-15P |
Output power capacity: | 0.685 kVA |
UPS-topologie: | Line-interactive |
Typische backup tijd op halve lading: | 10 min |
Typische backup tijd op volledige lading: | 2 min |
Hot-swap batterij: | Ja |
Output-aansluitingen: | NEMA 5-15R |
Vervangings-batterij cartridge: | BB - BP8-12 |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower CP685AVRLCD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
15 November 2024
7 November 2024
7 November 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024
22 Oktober 2024