K01-0000076-00
CP1350EAVRLCD/CP1500EAVRLCD
User’s Manual
2
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important instructions that should be followed during installation and
maintenance of the UPS and batteries. Please read and follow all instructions carefully during
installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit
breaker protection. DO NOT plug the UPS into an outlet that is not grounded. If you need to
de-energize this equipment, turn off and unplug the UPS.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower
Systems does not sell products for life support or medical applications. DO NOT use in any
circumstance that would affect the operation or safety of any life support equipment, with any
medical applications, or patient care.
CAUTION! The battery can energize hazardous live parts inside even when the AC input
power is disconnected.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area, free of conductive contaminants. (Please see specifications for
acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service
the battery. There are no user serviceable parts inside, except for the battery.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source
before servicing the battery or installing a computer component.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not
use with or near aquariums. Condensation from the aquarium can come in contact with metal
electrical contacts and cause the machine to short out.
CAUTION! DO NOT USE WITH LASER PRINTERS! The power demands of laser printers
are too large for a UPS.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following:
(1) PowerPanel® Personal Edition software (CD) x1; (2) USB cable (A+B type) x1; (3) Telephone
communication cable x1; (4) Power cord x2; (5) user manual x1; (6) UPS unit x1.
OVERVIEW
The CP1350EAVRLCD/ CP1500EAVRLCD provides automatic voltage regulation for
inconsistent utility power. The CP1350EAVRLCD/ CP1500EAVRLCD features 1215 Joules
of surge protection, and provides battery backup during power outages. The
CP1350EAVRLCD/ CP1500EAVRLCD ensures consistent power to your computer system
and its included software will automatically save your open files and shutdown your computer
system during a utility power loss.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR
EQUIPMENT
1.Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and
peripheral equipment does not exceed 1350 VA/ 1500VA.
2.Ensure that the equipment plugged into the battery power-supplied/surge outlets does
not exceed the UPS unit's rated capacity (1350VA/810W for CP1350EAVRLCD, 1500VA
3
/900W for CP1500EAVRLCD). If the rated unit capacities are exceeded, an overload
condition may occur and cause the UPS unit to shut down and the circuit breaker to trip.
3.If the power requirements of your equipment are listed in units other than Volt-Amps (VA),
convert Watts (W) or Amps (A) into VA by performing the calculations below. Note: The
equation listed below only calculates the maximum amount of VA that the equipment can EN
use, not what is typically used by the equipment at given time. Users should expect usage
requirements to be approximately 60% of the maximum power requirements:
Watts (W) x 1.67 = VA or Amps (A) x 230 = VA
Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate the
approximate requirements.
There are many factors that can affect the amount of power that your computer system will
require. The total load that you will be placing on the battery-powered outlets should not
exceed 80% of the unit's capacity.
BASIC OPERATION
DESCRIPTION
①
①
①
①① Power Switch
Used as the master on/off switch for equipment
connected to the battery power supplied outlets.
②
②
②
②② Power On Indicator
This LED is under the power switch. It illuminates
when the UPS outlets are providing power, free of
surges and spikes.
③
③
③
③③ LCD Module Display
High resolution and intelligent LCD display shows
all the UPS information with icons and messages.
For more information please check the “Definitions for Illuminated LCD Indicators” section.
④
④
④
④④ LCD Display Toggle/Selected Switch
The switch can be used to select the LCD display contents including Input Voltage, Output Voltage
and Estimated Run Time. The toggle frequency is set to one time per second. Holding the switch
for more than two seconds while running on battery will silence the buzzer.
⑤
⑤
⑤
⑤⑤ USB Port to PC
The USB port allow communication from the UPS to the computer. The UPS communicates its
status to the PowerPanel® Personal Edition software when connected with a USB port.
⑥
⑥
⑥
⑥⑥ Battery and Surge Protected Outlets
The unit has three battery powered/surge protected outlets for connected equipment and ensures
temporary uninterrupted operation of your equipment during a power failure.
⑦
⑦
⑦
⑦⑦ Full-Time Surge Protection Outlets
The unit has three always on surge suppression outlets.
⑧
⑧
⑧
⑧⑧ Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, broadband
network or Ethernet connection.
⑨
⑨
⑨
⑨⑨ AC Input
Connect the AC Power cord to a properly wired and grounded outlet.
⑩
⑩
⑩
⑩⑩ Circuit Breaker
Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.
①
①
①
①①
②
②
②
②②
③
③
③
③③
④
④
④
④④
⑤
⑤
⑤
⑤⑤
⑧
⑧
⑧
⑧⑧
⑨
⑨
⑨
⑨⑨
⑩
⑩
⑩
⑩⑩
⑦
⑦
⑦
⑦⑦
⑥
⑥
⑥
⑥⑥
Product specificaties
Merk: | CyberPower |
Categorie: | UPS |
Model: | CP1500EAVRLCD |
Kleur van het product: | Zwart |
Gewicht: | 12100 g |
LED-indicatoren: | Ja |
Aantal USB 2.0-poorten: | 1 |
Aantal Ethernet LAN (RJ-45)-poorten: | 1 |
Geluidsalarm(en): | Ja |
Responstijd: | 6 ms |
Uitgangsvermogen: | 900 W |
Accu/Batterij oplaadtijd: | 8 uur |
Temperatuur bij opslag: | -15 - 45 °C |
Frequentie: | 47/63 Hz |
Compatibele besturingssystemen: | Windows 98/Me/2000/NT/XP/Vista, Linux |
Mac-compatibiliteit: | Ja |
Afmetingen (B x D x H): | 100 x 374 x 249 mm |
Modem (RJ-11) poort: | 1 |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Output power capacity: | 1.5 kVA |
Netspanning, in bedrijf: | 230 V |
EMI/RFI geluidsfiltering: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberPower CP1500EAVRLCD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS CyberPower
15 November 2024
7 November 2024
7 November 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Apc
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
16 November 2024
15 November 2024
14 November 2024
14 November 2024
12 November 2024
22 Oktober 2024