Pagina 1/4
Quick Start Guide 930473A
1.0 Out-of-Box and Prior to Final Installation
1.1. Download the current manual, otherwise known as an Operation Guide,
which is available on the Documentation page at the following website
address:
http://www.cyberdata.net/products/voip/digitalanalog/intercomv3/docs.html
Note You can also navigate to the Documentation page by going to
www.CyberData.net and following the steps that are indicated by
the following figures:
2.0 Select Power Source
PoE Switch PoE Injector
Set PoE power type to Class 0 = 13W CAT6 cable recommendedā
for longer distances
Be sure you are using a non-PoE switch or port
Make sure port is not in trunk mode
Set port to full duplex/ 100mbps
Spanning Tree Protocol (STP) must be disabled or Portfast enabled
12
3
VoIP V3 Outdoor Intercom
Quick Start Guide
The IP Endpoint Company
Quick Start Guide 930473A
3.0 Power Test
3.1. Plug in the CyberData device and monitor the LED activity above the
ethernet port on the back of the Intercom. See the following figure:
3.2. The GREEN Link LED blinks off once during the boot up process and then
comes on again and remains constant (solid GREEN). The YELLOW
Activity LED may be blinking depending on the network activity.
During the initialization process, the GREEN Call Button LED should come
on and be constant (solid GREEN). After the Intercom has completed
booting, the LED will blink twice and then remain constant thereafter.
Normally, this process will take about 30 seconds. However, if no DHCP1 is
available, then this process could take up to 2 minutes.
3.3. When the Intercom has completed the initialization process, press and hold
the RTFM switch (SW1 button) for 3 seconds to announce the IP address.
This concludes the power test. Go to Section 4.0, "Connecting to a Network
in a Test Environment".
1. This only applies to firmware versions 6.x.x and later. For versions 5.1.2 and
earlier, the default static IP address is 10.10.10.10.
Link LED
Activity LED
Quick Start Guide 930473A
4.0 Connecting to a Network in a Test Environment
Note The following connections are usually needed for this procedure:
ā¢ PC
ā¢ PoE switch or injector
ā¢ CyberData device
4.1. In a test environment, use a PC that is connected to the same switch as a
single CyberData device. Note the subnet of the test PC.
4.2. Use the CyberData Discovery Utility program to locate the device on the
network. You can download the Discovery Utility program from the
following website address:
http://www.cyberdata.net/support/voip/discovery_utility.html
4.3. Wait for initialization to complete before using the Discovery Utility
program to scan for a device. The device will show the current IP address,
MAC address, and serial number.
4.4. Select the device.
Note If the IP address of the device is in the same subnet of the PC, then
go to Step 4.7.
4.5. If the IP address of the device is different from the subnet of the PC, then
complete the following steps:
4.5.1. Click the Details tab.
4.5.2. Click Adv. Config to manually configure settings with an available IP
address in the same subnet.
Note A gateway address of 0.0.0.0 or a subnet address of
255.255.255.255 will prompt you to enter a valid address.
4.5.3. Click OK after you are finished making changes.
4.6. A dialog box will prompt you to click OK after confirming the configuration
changes and will ask you to wait while the device reboots. Please wait for
the device to power up and wait for the Discovery Utility program to find
the device on the network.
Product specificaties
Merk: | CyberData Systems |
Categorie: | Intercomsysteem |
Model: | V3 SIP-enabled IP |
Kleur van het product: | Grijs |
Certificering: | FCC A, UL 60950\r\nIP64 |
Afmetingen (B x D x H): | 127 x 63.5 x 127 mm |
IP connectable: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met CyberData Systems V3 SIP-enabled IP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Intercomsysteem CyberData Systems
5 Maart 2024
5 Maart 2024
5 Maart 2024
5 Maart 2024
5 Maart 2024
Handleiding Intercomsysteem
- Intercomsysteem Philips
- Intercomsysteem Panasonic
- Intercomsysteem Bticino
- Intercomsysteem Abus
- Intercomsysteem Acti
- Intercomsysteem Alcatel
- Intercomsysteem Alecto
- Intercomsysteem Axis
- Intercomsysteem Byron
- Intercomsysteem DIO
- Intercomsysteem Elro
- Intercomsysteem Estom
- Intercomsysteem Foscam
- Intercomsysteem Gira
- Intercomsysteem Hikvision
- Intercomsysteem HQ
- Intercomsysteem Konig
- Intercomsysteem Marmitek
- Intercomsysteem Midland
- Intercomsysteem Monacor
- Intercomsysteem Siedle
- Intercomsysteem Silvercrest
- Intercomsysteem Smartwares
- Intercomsysteem Somfy
- Intercomsysteem Sygonix
- Intercomsysteem Toa
- Intercomsysteem Viking
- Intercomsysteem Becken
- Intercomsysteem Schwaiger
- Intercomsysteem Steren
- Intercomsysteem DoorBird
- Intercomsysteem EMOS
- Intercomsysteem Avidsen
- Intercomsysteem Comelit
- Intercomsysteem Extel
- Intercomsysteem M-e
- Intercomsysteem NuTone
- Intercomsysteem TCS
- Intercomsysteem Chacon
- Intercomsysteem Swann
- Intercomsysteem Valcom
- Intercomsysteem Fibaro
- Intercomsysteem GEV
- Intercomsysteem Planet
- Intercomsysteem Chamberlain
- Intercomsysteem DataVideo
- Intercomsysteem Dahua Technology
- Intercomsysteem Busch-Jaeger
- Intercomsysteem Russound
- Intercomsysteem Fanvil
- Intercomsysteem Aiphone
- Intercomsysteem Crestron
- Intercomsysteem ORNO
- Intercomsysteem Sonifex
- Intercomsysteem RTS
- Intercomsysteem Nortek
- Intercomsysteem Vimar
- Intercomsysteem ZKTeco
- Intercomsysteem Akuvox
- Intercomsysteem Bitron
- Intercomsysteem Hollyland
- Intercomsysteem Elcom
- Intercomsysteem Hanwha
- Intercomsysteem Leviton
- Intercomsysteem EtiamPro
- Intercomsysteem Pentatech
- Intercomsysteem Ritto
- Intercomsysteem Arenti
- Intercomsysteem Syscom
- Intercomsysteem Pentatron
- Intercomsysteem Vibell
- Intercomsysteem COMMAX
- Intercomsysteem Bintec-elmeg
- Intercomsysteem Eartec
- Intercomsysteem Gewiss
- Intercomsysteem Seco-Larm
- Intercomsysteem Tador
- Intercomsysteem WHD
- Intercomsysteem Mobotix
- Intercomsysteem FlyingVoice
Nieuwste handleidingen voor Intercomsysteem
17 November 2024
17 November 2024
16 November 2024
15 November 2024
5 November 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024