CONGRATULATIONS
on the purchase of your new professional switch mode battery charger. This charger is
included in a series of professional chargers from CTEK SWEDEN AB and represents the
latest technology in battery charging.
RECONDNORMAL AGM
MODE
LITHIUM
AGM
PROG R AM
ERROR
LAMP
LIT HIUM
PROG R AM
RECOND
PROG R AM
NORMAL
BAT TE RY
PROG R AM
HOW TO CHARGE
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the ring terminals
(M10) are incorrectly connected. The reverse polarity protection will ensure that the
battery or charger will not be damaged.
3. Press the MODE-button to select charging program.
4. Follow the indication lamps through the charging process.
The battery is ready to start the engine when is lit.
The battery is fully charged when is lit.
5. Stop charging at any time by disconnecting the mains cable from the wall socket.
MODE-
BUT T ON
POWER
LAMP
Read safety instruction
READY TO USE
EMPT Y
CHARGING
FULLY CHARGED
Temperature sensor
The temperature sensor works automatically
and will adjust the voltage to the ambient
temperature. Place the temperature sensor
as close to the battery as possible.
+
–
For batteries mounted inside a vehicle
1. Connect the charger according to the
vehicle manual.
2. Connect the charger to the wall socket.
3. Disconnect the charger from the wall socket
before disconnecting the battery.
1 2
6 • EN
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Program Explanation
NORMAL Normal battery program 14.4V, max 15A/max 25A.
Only for lead-acid batteries.
AGM
Use to charge most AGM batteries including AGM START/STOP types.
Some AGM should use lower voltage (NORMAL Mode), check battery
manual if unsure.
RECOND
Recond program 15.8V/1.5A
Use Recond to return energy to empty WET and Ca/Ca batteries.
Recond your battery once per year and after deep dischare to maximise
lifetime and capacity. The Recond program adds the Recond step to the
normal battery program. Only for lead-acid batteries.
BATTERY SIZE M15/M25 TIME TO 80% CHARGED
30Ah/40Ah 2h/1.5h
100Ah/100Ah 6h/3h
200Ah/200Ah 11h/6h
300Ah/500Ah 16h/16h
READY TO USE
The table shows the estimated time to charge a battery from empty to 80%
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT:
The charger has entered the energy save mode. This happens if the
charger isn´t connected to the battery within 2 minutes or the battery
voltage is below 2V.
LEAD-ACID
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the positive ring terminal connected to the battery's
positive pole?
2. Is the charger connected to a 12V battery?
3. Are the terminals short circuited?
4. Has charging been interrupted in or ?
Restart the charger by pressing the MODE-button. If charging is still
being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
EN • 7
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead plates
of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with a defect
battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYZE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be
replaced.
STEP 6 RECOND
Choose the Recond program to add the Recond step to the charging process. During the
Recond step voltage increases to create controlled gassing in the battery. Gassing mixes the
battery acid and gives back energy to the battery.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and
gives a pulse when necessary to keep the battery fully charged.
LEAD-ACID
1 2 3 4 5 6 7 8
NORMAL 15.8V Max 15A/25A
until 12.6V
Increasing voltage
to 14.4V,
max 15A/25A
Declining current
14.4V
Checks if voltage
drops to 12V 13.6V
max 15A/25A 12.9V–14.4V
12–1.2A
AGM 15.8V Max 15A/25A
until 12.6V
Increasing voltage
to 14.7V,
max 15A/25A
Declining current
14.7V
Checks if voltage
drops to 12V
13.6V
max 15A/25A
12.9V–14.7V
12–1.2A
RECOND 15.8V Max 15A/25A
until 12.6V
Increasing voltage
to 14.4V,
max 15A/25A
Declining current
14.4V
Checks if voltage
drops to 12V
Max 15.8V
Max 1.5A 13.6V
max 15A/25A 12.9V–14.4V
12–1.2A
Time limit: 8h 20h 16h minutes3 2h or 6h
10 days charge
cycle restarts if
voltage drops
Charge cycle restarts
if voltage drops or
24h time passed


Product specificaties

Merk: Ctek
Categorie: Batterij-oplader
Model: M15

Heb je hulp nodig?

Als je hulp nodig hebt met Ctek M15 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Batterij-oplader Ctek

Handleiding Batterij-oplader

Nieuwste handleidingen voor Batterij-oplader