Pagina 1/4
EN • 5
MANUAL
CONGRATULATIONS
on the purchase of your new professional switch mode battery charger. This charger is
included in a series of professional chargers from CTEK SWEDEN AB and represents the
latest technology in battery charging.
ERROR
LAMP
HOW TO CHARGE
1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains
cable is connected to the wall socket. The error lamp will indicate if the ring terminals
(M10) are incorrectly connected. The reverse polarity protection will ensure that the
battery or charger will not be damaged.
3. Follow the indication lamps through the charging process.
The battery is ready to start the engine when is lit.
The battery is fully charged when is lit.
4. Stop charging at any time by disconnecting the mains cable from the wall socket.
POWER
LAMP
For batteries mounted inside a vehicle
1. Connect the charger according to the
vehicles manual.
2. Connect the charger to the wall socket.
3. Disconnect the charger from the wall socket
before disconnecting the battery.
1 2
Read safety instruction
READY TO USE
EMPT Y
CHARGING
FULLY CHARGED
+
Temperature sensor
The temperature sensor works automatically
and will adjust the voltage to the ambient
temperature. Place the temperature sensor
as close to the battery as possible.
–
6 • EN
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the positive ring terminal connected to the battery's
positive pole?
2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in or ?
Restart the charger. If charging is still being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
BATTERY SIZE (Ah) TIME TO 80% CHARGED
40Ah 1.5h
100Ah 3h
200Ah 6h
300Ah 16h
READY TO USE
The table shows the estimated time to charge a battery from empty to 80%
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT:
The charger has entered the energy save mode. This happens if the
charger isn´t connected to the battery within 2 minutes or the battery
voltage is below 2V.
TECHNICAL SPECIFICATIONS
Model number 1093
INPUT 220–240VAC, 50–60Hz, max 2.9A
OUTPUT 25A, 12V
Start voltage 2.0V Lead Acid batteries
Back current drain* Less than 2.3Ah/month
Ripple** Less than 4%
Ambient
temperature -20°C to +50°C (-4°F to +122°F)
Battery types All types of 12V Lead Acid batteries (WET, EFB, Ca/Ca, AGM and
GEL).
Battery capacity 40–500Ah, Lead Acid battery types
Insulation class IP44
Warranty 2 years
*) Back current drain is the current that drains the battery if the charger is not connected to
the mains. CTEK chargers have a very low back current.
**) The quality of the charging voltage and charging current is very important. A high
current ripple heats up the battery which has an aging effect on the positive electrode.
High voltage ripple could harm other equipment that is connected to the battery. CTEK
battery chargers produce ver y clean voltage and current with low ripple.
EN • 7
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead plates
of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that charging proceeds with a defect
battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be
replaced.
STEP 6 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 7 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage and
gives a pulse when necessary to keep the battery fully charged.
1234567
15.8V Max 25A until 12.6V Increasing voltage to
14.4V, max 25A
Declining current
14.4V
Checks if voltage drops
to 12V
13.6V
max 25A 12.9V–14.4V
20–1.2A
Time limit: 8h 8h 20h 16h 3 minutes
10 days
charge cycle restarts if
voltage drops
Charge cycle restarts if
voltage drops
CHARGING STEPS


Product specificaties